• 沒有找到結果。

The correlation of the embryo implantation rate with uterine arterial impedance in in vitro fertilization and embryo transfer

N/A
N/A
Protected

Academic year: 2021

Share "The correlation of the embryo implantation rate with uterine arterial impedance in in vitro fertilization and embryo transfer"

Copied!
1
0
0

加載中.... (立即查看全文)

全文

(1)

The correlation of the embryo implantation

rate with uterine arterial impedance in in vitro

fertilization and embryo transfer

簡立維

Chien LW;Tzeng CR;Chang SR;Chen AC

摘要

Abstract

The influence of uterine blood flow impedance on embryo implantation rate was investigated by transvaginal color Doppler sonography examination before embryo transfer. A total of 108 women undergoing in vitro fertilization (IVF) procedures and who had at least one good quality embryo for transfer to the uterus received Doppler evaluation before embryo transfer. Color flow imaging with blood flow waveform analysis from bilateral uterine arteries was obtained to calculate the mean pulsatility index (PI). The correlations between mean PI with the pregnancy rate and the embryo implantation rate (number of embryos implanted/number of embryos transferred) were analyzed. Patients were grouped according to the mean PI value, and the pregnancy rate and embryo implantation rate were 25% (5/20) and 10.7% (9/84), respectively, with a PI < 2.0 (n = 20); 27.5% (14/51) and 12.2% (12/109), respectively, with a PI = 2.00-2.49 (n = 51); 9.5% (2/21) and 3.5% (2/57), respectively, with a PI = 2.50-2.99 (n = 21); and 6.3% (1/16) and 4.3% (2/47), respectively, with a PI [symbol: see text] 3.0 (n = 16). There were no significant differences in either pregnancy rate or embryo implantation rate between the groups with mean PI values less than 2.00 and between 2.00 and 2.49. If a mean PI value of 2.50 was used as the cut-off value, both the pregnancy rate and embryo implantation rate were significantly higher in patients with a mean PI less than 2.50 (p < 0.05). The uterine arterial impedance measured by the Doppler sonographic examination is a non-invasive method for evaluating the endometrial response and a mean uterine PI value of 2.5 can be used as a cut-off value to identify optimal uterine receptivity before embryo transfer

. . .

參考文獻

相關文件

Estimated resident population by age and sex in statistical local areas, New South Wales, June 1990 (No. Canberra, Australian Capital

(c) Draw the graph of as a function of and draw the secant lines whose slopes are the average velocities in part (a) and the tangent line whose slope is the instantaneous velocity

For 5 to be the precise limit of f(x) as x approaches 3, we must not only be able to bring the difference between f(x) and 5 below each of these three numbers; we must be able

[This function is named after the electrical engineer Oliver Heaviside (1850–1925) and can be used to describe an electric current that is switched on at time t = 0.] Its graph

6 《中論·觀因緣品》,《佛藏要籍選刊》第 9 冊,上海古籍出版社 1994 年版,第 1

The first row shows the eyespot with white inner ring, black middle ring, and yellow outer ring in Bicyclus anynana.. The second row provides the eyespot with black inner ring

Wang, Solving pseudomonotone variational inequalities and pseudocon- vex optimization problems using the projection neural network, IEEE Transactions on Neural Networks 17

Hope theory: A member of the positive psychology family. Lopez (Eds.), Handbook of positive