High Content Cellular Analysis

Hardware | Software | Reagents | Labware

(2)
(3)

Table of Contents

Introduction 1

BD Pathway Hardware 3

Hardware Features and Benefits 4

BD PathwaySoftware 5

Software Features and Benefits 10

Applications 11

Reagents 16

Technical Specifications 17

Technical and Training Support 19

Ordering information 20

© 2007 Becton, Dickinson and Company. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in retrieval systems, or translated into any language or computer language, in any form or by any means: electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without prior written permission from BD Biosciences. Purchase does not include or carry any right to resell or transfer this product either as a stand-alone product or as a component of another product. Any use of this product other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited. Prices and product availability are subject to change without notice.

BD, BD Logo and all other trademarks are the property of Becton, Dickinson and Company. © 2007 BD

(4)

Automated high-content imaging technologies are becoming increasingly popular tools within the cell analysis laboratory.

Flow cytometry technology is a tool of choice for the life scientist seeking quantitative analysis of cell populations. Flow cytometry yields high cell throughput and multiplexible fluorescence intensity measurements, advantages unmatched by other analytical technologies. With added cell sorting (FACS) capability, researchers can collect subpopulations of interest for expansion and further analysis, enhancing “flow’s” value as a cell biology research tool. Common applications of flow cytometry include population analysis using biomarkers, phosphorylation profiling of signaling pathways, and multiplexed bead arrays.

Imaging is an ideal companion technology to flow cytometry. In addition to multiplexed fluorescence intensity measurements of cell populations, imaging provides the ability to measure cellular features such as size, shape, and movement. Since cells can be visualized without removing them from their culture environment, they can be analyzed over time to provide real-time information about cellular responses to stimuli. Coupled with 3-dimensional confocal techniques, live-cell imaging can provide a level of biological detail not possible using conventional analytical tools.

In combination, flow cytometry technology and high-content imaging provide a comprehensive cell analysis solution.

Imaging complements flow cytometry and FACS

Flow Cytometry Imaging

Provides statistical analysis of cell populations via fluorescence intensity

Measures fluorescence intensity, localization, cell motility, and morphology

Provides single-cell resolution using PMT detection technologies

Provides subcellular resolution using CCD camera technologies

Rapid analysis of thousands to

hundreds of thousands of cells Rapid analysis of one to thousands of cells Cells must be prepared in suspension.

Also compatible with multiplexed bead arrays

Is ideally suited for adherent cells and tissues

Multiplexible (12+ colors) Multiplexible (4+ colors) Cells are normally discarded but can

be collected following sorting Cells can be revisited and monitored over time Key strengths:

• Cell preparation (sorting) • Statistical population analysis • Low abundance events

Key strengths:

• Morphological measurements • Spatial analysis

• Images can be reanalyzed • Visual data

Introduction

Flow cytometry and imaging provide comprehensive cell analysis

(5)

Cells are plated into multiwell plates, culture slides, or onto other imaging compatible substrates.

What is high-content cell analysis?

With the BD Pathway high- content cell analyzers, images are captured in either confocal or widefield modes providing the best possible images for analysis. Proprietary software algorithms segment the image.

The segmented image may be further divided into regions of interest (ROI) where fluorescence measurements are made.

These measurements can include fluorescence intensity ratios, granularity, morphological features, fluorescence localization, and more.

Individual cells may then be classified into different categories based on end-point or kinetic response profiles at the cell, well, or plate level.

Data is analyzed and presented within the provided software, or it can be exported for analysis within third party software.

(6)

BD Pathway 45 High-Content Cell Analyzer

The BD Pathway 435 system is a compact benchtop for high-content cellular imaging and is ideally suited for endpoint (fixed cell) biological assays. Light from a mercury metal halide lamp, introduced through a liquid light guide, provides full-spectrum illumination. The lamp is engineered for long life and never needs alignment. The laser auto focus, fast filter changers, spinning disk confocal optics, and a high-resolution CCD camera enable the BD Pathway 435 system to record high-quality fluorescence images from multiwell plates and slides. A transmitted light canopy provides the ability to capture bright-field images that can be overlaid onto fluorescence images. The system comes with powerful, flexible imaging processing and analysis software.

BD Pathway Hardware

5 Position Dichroic Mirror High NA Objective

8 position Excitation Filter Wheel

8 Position Emission Filter Wheel

CCD Camera

Confocal Spinning Disk Slider

Long-life, alignment free halide lamp with liquid light guide

Imaging Plate or Slide

Schematic representation of the BD Pathway 45 light path

BD Pathway 855 High-Content Cell Analyzer

The BD Pathway 855 system offers the ultimate in flexibility for high-content imaging of live and fixed cells. Equipped with environmental control and liquid handling, the system has full-spectrum (340–700 nm) illumination, laser auto focus, and fast filter changers. These powerful features, along with spinning disk confocal optics and a cooled CCD camera, enable the BD Pathway 855 system to rapidly record high-resolution fluorescence images from multiwell plates and slides. The system comes with powerful imaging software to perform a broad range of fluorescence-based kinetic and endpoint biological assays.

5 Position Dichroic Mirror High NA Objective

8 position Excitation Filter Wheel

8 Position Emission Filter Wheel

CCD Camera

Confocal Spinning Disk Slider

Imaging Plate or Slide

8 position Excitation Filter Wheel

5 Position Dichroic Mirror Mercury Arc

Lamp #1

Mercury Arc Lamp #2

Schematic representation of the BD Pathway 855 light path.

The BD Pathway 435 system is designed for:

• Labs needing a dedicated high-content image acquisition and analysis workstation

• Researchers that primarily work on endpoint applications with fixed cells or tissues

• Labs that routinely conduct fluorescence image documentation and analysis

The BD Pathway 855 system is designed for:

• Core facilities or labs needing a versatile solution for live cell and endpoint fluorescence imaging

• Researchers conducting live cell assay development for which viability of the cells is important

• Investigators requiring a variety of dynamic imaging modes on live cells with image-as-you-add capability.

(7)

Feature Benefits BD Pathway

435 BD Pathway 855 High-performance laser-based autofocus High image acquisition speed can be obtained

(under 5 minutes per 96-well plate). The system also can be switched to camera-based autofocus or combined autofocus modes when more control over image acquisition is needed.

✓ ✓

Real-time, true-optical confocal

spinning disk Permits automated switching between widefield and confocal imaging with movable disk. Delivers high-resolution 3-D images without background fluorescence often associated with widefield imaging systems.

✓ ✓

High-precision x,y,z linear-motor positioning

Allows high-speed, precise image montage (tiling) without the need for software processing. Increased cell counts are possible by capturing multiple adjacent images per sample.

✓ ✓

Proprietary motionless stage with

movable optics Ensures sample stability during image acquisition.

Also allows loosely adherent and suspension cells

to be imaged.

✓ ✓

Flexible computer-controlled independent excitation, emission, and dichroic filters

Provides high-speed, fully automated imaging of

fluorescently labeled samples.

✓ ✓

Long-life, alignment-free illumination Permits full-spectrum (360-700 nm) imaging.

No light alignment required. Long lamp life

(1500 hours) and low maintenance cost.

Dual-mercury arc-lamp illumination Permits full-spectrum (340-700 nm). Imaging allows the illumination of the sample through

one of up to 16 different excitation filters.

Robot compatibility Allows high-throughput, unattended

instrument operation.

✓ ✓

On-stage liquid handling Enables a variety of dynamic imaging modes on

live cells with image-as-you-add capabilities.

Environmental control Keeps cells alive during extended imaging periods.

Transmitted light Permits superimposition of transmitted light images onto fluorescence images to assist with localization

of cellular events.

✓ ✓

Binocular eyepiece Allows direct viewing of cells in both fluorescence

and transmitted light modes.

Interchangeable objectives Enables a wide range of imaging options at

multiple resolutions.

✓ ✓

Hardware Features and Benefits

(8)

The BD Pathway software provides a suite of integrated tools to accomplish the tasks of high-content cellular analysis—from image acquisition and analysis to data analysis and visualization. The software is designed to accommodate the needs of many users, from users needing push-button control of pre-defined applications to advanced assay developers. The software utilizes several easily accessible interfaces.

Powerful, flexible, yet easy to use

Routine Assay User

Easy as 1-2-

Users wanting to run preconfigured applications can easily do so with the Assay Launch dialog. Whether provided by BD or developed by the laboratory, new applications can be added to the launch dialog for easy access at any time.

The Assay Launch dialog provides the ability to:

1. Select a preconfigured application

2. Select the wells of the plate to be analyzed . Run the assay

There is also a convenient tool for making any necessary edits to the application.

Routine Assay User Occasional/Custom User Assay Developer

Predefined applications are activated through a single push-button launch window.

A number of step-through Application Wizards are provided to allow optimization of commonly run applications.

Advanced users can build custom instruction sets through an intuitive macro builder that controls all components of the system.

Assay launch dialog for simple control of routine applications.

BD Pathway Software

Once selected, the application launches an interface allowing the user to view progress in realtime.

(9)

Occasional/Custom User

Step-by-step set up of applications

Users requiring easy optimization of their routine high-content experiments can utilize BD Pathway’s unique Application Wizards. These preconfigured wizards provide guided access to a number of key settings of the instrument. The user simply steps through the dialog boxes, making any necessary adjustments, reviews the summary tab, and launches the application. The Wizards require only basic knowledge of imaging, allowing the cell biologist to configure the system using clear, easy to understand language.

Application Wizards provide guided, step-through instructions in easy to understand language.

BD Pathway Software (Cont’d)

You can apply the settings used in the running of an Application Wizard to multiple plates during reanalysis.

For more advanced analysis, additional tools are available to step the user through customized analysis algorithms. The user simply selects the experiment data, the analysis type, and adjusts some basic settings.

Then, the user can experiment with a variety of settings before selecting those to apply. Once defined, these settings can be saved for consistent application across any number of plates.

(10)

Assay Developer

Full instrument control

The power and flexibility of the BD Pathway software allows advanced users to develop novel applications unique to their experimental needs. An intuitive, step-wise macro builder allow the user to interact with every setting of the instrument and make precise adjustments to the system. The user can select from hundreds of defined “actions” to assemble into a macro (instruction set) for the instrument. The step-wise macro builder provides unprecedented flexibility in image acquisition

BD Pathway Software (cont’d)

Advanced Features

The BD Pathway software includes a comprehensive set of advanced features for image acquisition, image visualization, and live cell dynamic imaging (BD Pathway 855 instrument) to meet your ongoing research needs.

Confocal Z Stack acquisition

The BD Pathway system provides a selectable spinning disk confocal, which allows users to take advantage of both widefield and confocal imaging methods. Based on experimental conditions and imaging requirements, the confocal capability provides the flexibility to remove out-of-focus haze for improved image quality and analysis. A plate-wide collapsed Z Stack provides the highest quality image while retaining all the fluorescence information throughout the depth of the specimen.

3D volume rendering of an image Z stack for image visualization.

-D visualization

The 3-D volume rendering tool is built in and allows image Z Stacks to be viewed from any angle. The image views can also be rendered to develop a 3-D rotational projection and video sequence.

(11)

Calcium response in Fluo-4® labeled HeLa cells after stimulation with an agonist Each line in Panel B represents intensity over time for single-cell response to the specific agonist (first drug addition) and positive control (second drug addition). Cells have been classified using the BD Pathway software into positive responders (red) and negative responders (green) for the specific agonist. Black line is the average response of all cells. Panel A is a segmented image from a single time point after drug addition showing positive (red) and negative (green) cells with cell ROI (region of interest) numbers.

Image montage

(tiling without software stitching)

The BD Pathway system offers advanced hardware and software capabilities for building the image montage (tiles.) Experiments that require multiple locations, a larger cell population, or a single expanded field of view image can easily be set up through a montage capture dialog.

For example, Neuron length may be measured over a number of fields of view with a high degree of precision and accuracy.

BD Pathway Software (cont’d)

A B

Live cell dynamics

The BD Pathway 855 system supports a variety of live cell imaging applications such as calcium kinetics using single or dual wavelength dyes.

With the included liquid handling capability, compound additions can be coordinated with imaging to ensure analysis of events in real-time.

(12)

Data Analysis and Visualization

The BD Pathway system includes a wide range of data analysis and visualization tools for high-content image data.

Endpoint and kinetic data can be analyzed using the BD Pathway system. Examples of data analysis and visualization tools include:

• Bar charts

• Scatter plots

• Dose-response curves

• Heatmaps

• Cell-by-cell or well-by-well analysis

• Cell scoring

(percentage of cells responding)

• Z-scores

Heatmap display showing average value of a measurement parameter on a well-per-well basis. The heatmap provides an excellent overview of a drug’s dose response activity.

Bar chart comparing the response levels of two data sets.

Multiple dose-response curves can be plotted on the same chart allowing, comparison between different experimental conditions.

BD Pathway Software (cont’d)

Scatter plot example showing the comparison between area of the cell and rate of rise parameters.

(13)

Feature Benefits BD Pathway

435 BD Pathway 855 High-content analysis software included Most high-content applications can be run without

the need to purchase applications-specific software.

✓ ✓

Powerful analysis capabilities Flexible software provides a variety of analysis tools,

enabling a broader range of applications.

✓ ✓

Comprehensive software suite From image acquisition and analysis to data analysis and visualization, BD Pathway software provides a

complete solution.

✓ ✓

Flexible export of images and data Support for unencrypted 16-bit TIFF, JPEG, and BMP file formats, plus export of delimited text files, allows you to migrate your data to third party software provider solutions.

✓ ✓

Integrated 3-D volume rendering Easy capture and visualization of 3-D images

and movies.

✓ ✓

Advanced kinetic control with scheduling Run a number of dynamic live-cell applications including calcium flux imaging and time-lapse

microscopy.

Software Features and Benefits

(14)

Assay Modes

Fluorescence intensity Fluorescence distribution

and colocalization Morphology Motility

and migration When to use • Biological response appears as a

change in fluorescence intensity but other fluorescence detection methods are ineffective

• Few cells are available (e.g. primary cells, stem cells)

• Cell population is heterogeneous

• Total fluorescence does not change within a cell following activation

• Identify where within a cell an event occurs

• Colocalize cellular events

• Biological response measured by changes in cell size or shape

• Biological response is measured as cellular movement

Example of BD Pathway application

• Calcium kinetics

• Mitotic index

• Live/dead

• Cell viability

• Cytotoxicity

• Cell cycle

• Apoptosis

• Mitochondrial health (JC-1,TMRE, MitoTracker)

• Steatosis

• IkB degradation

• Reactive oxygen species

• Whole organism imaging (c. elegans, arabidopsis, zebrafish)

• Tissue arrays

• Cytoplasmic/ nucleus translocation assays

• DNA damage (and repair)

• Mitotic defects (monopolar spindles)

• Apoptosis

• Synaptic junction localization

• FISH

• 3-D cell imaging

(stem cells, pancreatic islets)

• Transfluor® GPCR (receptor internalization)

• Tube formation (angiogenesis)

• Neurite outgrowth

• Micronucleus assay

• Morphometric analysis (tubulin)

• Apoptosis

(nuclear size, granularity)

• Cell migration

• Chemotaxis

• Cell invasion

Modes can be multiplexed to develop unique applications

Applications

The power and flexibility of the BD Pathway system enables researchers to develop and perform a wide array of high-content biological applications. A number of preset applications together with application wizards for assay customization are available, making it possible to correlate basic biological processes, with quantifiable measurements.

The BD Pathway high-content cellular analyzer provides a balance between ready-to-run applications and complete assay design, as well as novel advanced applications.

Our applications take advantage of our live-cell kinetic and confocal capabilities, and can be run in multi-plate high- throughput and/or low-throughput modes, depending on the need. The systems support a large variety of plate and slide types, with flexibility to modify existing applications or to develop your own.

Imaging applications can be divided into the following four assay modes involving the measurement of fluorescence intensity, fluorescence distribution, morphological changes in fluorescently labeled structures, and migration of fluorescently labeled cells.

(15)

Fluorescence Intensity Applications

Quantitative Cell Cycle Analysis

Many drugs impact cell cycle in some way. Whether carrying out drug screening experiments or analyzing cell cycle directly in an academic lab, determining the percentage of cells in a particular phase of the cell cycle is very important.

Two of the most commonly studied phases are S phase (DNA synthesis) and M phase (Mitosis). BD Biosciences antibody reagents enable the study of both using a simple one-step staining procedure.

Applications (cont’d)

Effects of colcemid and aphidicolin on the cell cycle HeLa cells were seeded into a BD Falcon Imaging 96-well plate cultured overnight, then treated for 2 h with either 500 ng/mL colecimid (Panel B), 500 ng/mL aphidicolin (Panel C) or vehicle control (Panel A). M and S phase cells were detected in a single staining step using the BD Bioimaging Cell Cycle Kit which uses a directly conjugated anti-phospho-Histone H3 antibody to detect M phase cells and a directly conjugated anti-BrdU antibody to detect cells in S phase. Merged pseudocolored 20X images are shown in Panels A–C. The BrdU signal is pseudocolored green, the phosho-Histone H3 signal is pseudocolored red and Hoechst stained cells are pseudocolored blue. Data was analyzed using BD Pathway system software and shows that colcemid caused an increase in the percentage of cells in M phase over controls and that aphidicolin produced a dramatic decrease in the number of cells in S phase.

A B

C D

(16)

Calcium Kinetics

Simultaneous Measurement of Calcium Concentration and Mitochondrial Membrane Potential in Astrocytoma Cells Using Two Ratiometric Fluorescence Probes

Measurement of cytosolic free calcium concentration has been employed successfully to unravel intracellular signaling pathways, identify G-protein coupled receptors (GPCRs), and cAMP levels using specifically modified ion channels. Ratiometric dyes such as Fura-2 or JC-1 overcome the problem of uneven dye loading by exploiting a shift in the excitation (Fura-2) or emission (JC-1) wavelengths upon binding of calcium. This shift is independent of the dye concentration and can be extracted by taking two images in rapid succession and dividing them to generate a ratio measurement. The BD Pathway system enables the user to measure calcium changes reliably using ratiometric dyes.

These experiments demonstrate how the BD Pathway 855 high-content cell analyzer can be used to make simultaneous single-cell kinetic measurements of calcium and mitochondrial membrane potential changes.

Calcium kinetics Stably transfected (VR1 receptor) NIH 3T3 cells were plated in a BD Falcon Imaging 96-well plate and cultured overnight. Cells were then labeled with Fura-2 and placed into the environmental chamber of a BD Pathway 855 system where the cells were maintained at 37°C and 5% CO2. Specific and control agonists were added using on-board fluidics, and the cell responses were measured. The image mosaic on the left shows the time series of pseudocolored (for intensity) images from a single well. The first image in the series shows the single-cell ROIs imprinted on the image. The panel on the right shows the intensity over time for each cell. The kinetic data is further classified by the software into response types based on rate of rise and rate of fall parameters for the specific agonist.

Cell line courtesy of Dr. Mike Iadarola, NIDCR, NIH, Bethesda, MD.

Applications (cont’d)

(17)

Dose-response curves Dose-response curves and EC50 values generated by the BD Pathway software are shown for phospho-H2AX (Panel A) and 53BP1 (Panel B) probes. N=6 ± SEM.

Applications (cont’d)

Induced DNA damage HT1080 cells were plated in a BD Falcon Imaging 96-well plate and cultured overnight.

Cells were then treated with a dilution series of H2O2 to induce DNA damage, or with vehicle control; cells were allowed to recover for 30 min. Cells were then fixed and permeabilized and stained with antibodies to detect DNA damage (phospho-H2AX, pseudocolored red, Panel A and B) and DNA repair (53BP1, pseudocolored green, Panel C and D).

Cropped 40X confocal images from a control and a treated well are shown in panels A–F. Panel E and F are merged pseudocolored images and show the colocalization of the two probes as a yellow to orange color.

Fluorescence Distribution and Colocalization Application

DNA Damage and Repair: Quantitation of Sub-Cellular Events Using Automated Confocal Imaging

Cancer prevention treatment and aging are of major relevance in understanding the mechanisms by which cells respond to, and repair, DNA damage. Additionally, by assessing the effect of compounds in drug screening campaigns on DNA integrity, an early indication of genotoxicity can be detected.

The DNA damage and repair application measures the presence of DNA damage and its repair using antibody probes.

This application also detects proteins involved in the cellular response to DNA damage.

Data analysis Using customizable and highly flexible software tools, automated image analysis was performed. Nuclear boundaries were generated using the Hoechst images (Panel A). The foci images from the two probes, phospho-H2AX (Panel C), and 53BP1 (Panel D), were segmented and analyzed within the nuclear boundaries.

The BD Pathway software allows analysis of many different parameters such as foci count, intensity, size, area and colocalization (Panel B).

(18)

NGF-induced neurite outgrowth PC-12 cells were plated in a BD Falcon Imaging 96-well plate coated with rat tail collagen and cultured overnight.

Cells were then subjected to a neurite differentiation protocol that included a dilution series of nerve growth factor (NGF) for 10 days. Cells were then fixed and permeabilized and stained with anti-tubulin antibody and Hoechst. Representative 20X pseudocolored images of control and treated wells are shown; neurites are pseudocolored green and nuclei are pseudocolored blue.

Morphology Application

Quantitative High-Content Analysis of Neurite Outgrowth

Changes in the pattern of neurite outgrowth have been implicated in neurodegenerative disorders as well as traumatic injuries.

Measurement of neurite outgrowth using an automated image-based assay can be beneficial in the research, screening, and validation phases of the drug discovery process.

This is a multi-parameter assay in which the software segments the neuronal cell body and analyzes fluorescently labeled neurites with respect to their total length, maximum length, root count, extremities count, node points, and segment count.

BD Pathway software-generated image and segmentation masks Panel A displays a pseudocolored neurite image. Segmentation masks displaying cell bodies (Panel B, colors randomly assigned by the software), cell bodies and neurites (Panel C), and neurite branch levels (Panel D, primary, secondary, tertiary and quaternary branches are colored green, blue, yellow and cyan, respectively).

Dose-response curves NGF dose-response curves and EC50 values generated by the BD Pathway software are shown for four measurement parameters, maximum neurite length, neurite extremity count, neurite root count, and total neurite length. N=10 ±SEM.

Applications (cont’d)

(19)

Cell Cultureware for Bioimaging

BD Falcon and BD BioCoat

Microplates for Imaging Applications

BD Biosciences also offers microplates to support manual and automated high-throughput imaging settings. With black walls to minimize well-to-well crosstalk, these plates feature an especially thin, clear bottom that has been specifically developed for imaging applications. Our imaging plates are available in 96 or 384 well formats, either uncoated (tissue culture treated surface) or coated with Collagen I or Poly-Lysine.

Microplates for Manual and Automated High-Throughput Imaging Applications

description volume wellshape qty/pack qty/case cat. no.

BD BioCoat 384-well Microplate, Black/Clear, Collagen I coated* 90 µL Flat-Bottom 5 50 356667

BD BioCoat 384-well Microplate, Black/Clear, Poly-D-Lysine-coated* 90 µL Flat-Bottom 5 50 356663

BD Falcon 96-well Imaging Plate, Black/Clear, Tissue Culture treated 390 µL Flat-Bottom 8 32 353219

BD Falcon 384-well Microplate, Black/Clear, Tissue Culture treated 120 µL Flat-Bottom 5 50 353962

* Collagen I and Poly-Lysine coatings are available through our custom coating program.

Please contact your local BD Biosciences representative for more information.

Reagents

BD Biosciences Bioimaging Certified Reagents are certified for optimal performance based on an internal qualification program.

For BD to certify a reagent, an antibody must pass a number of tests that focus on high-content applications for which reproducibility is essential. These tests include:

Exceeding a signal intensity threshold over background in commonly used cell lines

Working with widely used fixation and permeabilization methods

Localizing to the appropriate region within a cell

Showing an appropriate response following stimulati

* For a current list of Bioimaging Certified Reagents, please visit us at www.bdbiosciences.com/bcr

Representative images using BD Bioimaging Certified primary conjugated antibodies. Pseudo-colored merged images of nerve growth factor treated PC12 cells. Nuclei are psuedo-colored blue in all images.

Neurites were stained with:

Panel A: Alexa Fluor® 488 conjugated anti ß-tubulin antibody (green) Panel B: Alexa Fluor® 555 conjugated anti ß-tubulin antibody (red) Panel C: Alexa Fluor® 647 conjugated anti ß-tubulin antibody (magenta) Images were acquired using a 20X objective (0.75 NA).

A

B

C

(20)

Technical Specifications

Optics BD Pathway 435 BD Pathway 855

Proprietary, fully integrated optical design

Selectable laser-based and/ or camera-based autofocus

Motionless stage handles 96 or 384 well plates, microscope slides, and chamber slides

X, Y resolution: 100 nm (mechanical)

Z resolution: 50 nm (mechanical)

5 images per second capture rate

Works with Olympus 4X, 10X, 20X, 40X objectives

Montage capability for large field imaging

Automation ready

(requires robotics integration package)

Integrated temperature (ambient to 40°C) and CO2 (ambient to 5%) control n/a

Imaging modes Confocal fluorescence, widefield fluorescence, brightfield Confocal fluorescence, widefield fluorescence, brightfield

Illumination Sources Single, EXFO X-cite, metal halide with liquid light guide;

multi-position LED grid Dual, HBO 100 W mercury arc; single automated LED Confocal Unit

Nipkow spinning disk

Disk sampling rate 1,000 fps 1,000 fps

Pinhole size 70 μM 70 μM

Filter Configurations

Excitation 8 16

Dichroic 5 5

Emission 8 8

Automated control

Independent operation

Detection and Observation

High resolution cooled CCD camera 12 Bit, high QE, effective pixels 1392 x 1040,

pixel size 6.45 x 6.45 pixels 12 Bit, high QE, effective pixels 1392 x 1040, pixel size 6.45 x 6.45 pixels

Binocular eyepiece for direct sample viewing in confocal or widefield mode n/a

Liquid Handling and Environmental Control On-stage pipet head with single-position syringe

(2-100 μL) n/a

Mixing capability (tituration) n/a

Disposable pipette tips n/a

Environmental Control (ambient to 38°C) and CO2 (ambient 0-5% +/-.5%) n/a

(21)

Software BD Pathway 435 BD Pathway 855

Advanced imaging software with hardware

auto-detection capabilities

Automated focus and image acquisition

Automated segmentation and region of interest

(ROI) identification

Interactive data and image navigation

Concurrent multiple ratiometric dye kinetics

(US Patent 5,332,905) n/a

Z sectioning and 3-D rendering

Hierarchical data classification algorithm

Data analysis module for Microsoft® Excel®

Preconfigured and user-configurable applications

Support for endpoint applications

Support for kinetic applications

BMP, TIFF, and TXT formats for data export

Computer (minimum specification)

Pentium IV running Microsoft® Windows® XP Professional

2 GB RAM

256 MB video card

250 GB SATA hard drive

24" wide aspect ratio LCD flat panel display Optional

DVD burner

Robotics Integration Package

Access door with safety light curtain Not required Optional

Software interface to multiple scheduling systems Optional Optional

Physical Dimensions

Width 33.5 inches (85 cm) 43 inches (109 cm)

Depth 19 inches (48 cm) 41 inches (104 cm)

Height 13.5 inches (34 cm) 66 inches (168 cm)

Technical Specifications (cont’d)

(22)

• BD Bioimaging Education Center

This 2700 square-foot, state-of-the-art training center houses two classrooms, a wet lab, a microscopy suite, a conference center, and common area with a refreshment center. The center offers demonstration instruments, basic and advanced training classes,

“getting started” courses, and technical presentations for a variety of BD technologies. This center complements our existing training facilities in San Diego, San Jose, Boston, Basel, Tokyo, and Seoul.

• Technical Application Scientists

Our field-based technical specialists support customers’ high-content applications worldwide. These Masters or PhD level scientists with many years of relevant cell analysis expertise, ensuring your success in implementing high-content cellular applications.

• Custom BD Pathway software services

BD offers expert software scripting and optimization to support custom application development. If you are looking for custom high-content analysis research, our team of software and technical specialists are available to help you reach your goal. Our custom software support includes a feasibility study, product development, training, and support. Please contact your local sales representative for further details.

• Customer support

BD provides exceptional customer support through a combination of phone, e-mail, web, and field support services. We also can monitor and view our customers’ experiments from our site, allowing for rapid diagnosis and resolution of the situation at hand. Our support team has knowledge of all of our product lines and is readily available to provide assistance.

• Warranty and Extended Service Contract options The BD Pathway instrument includes a one-year service contract providing repair and preventive maintenance. We offer multiple tiers of extended service contracts based on customer needs.

Successful implementation of high-content analysis requires excellent technical support and application specific training.

BD associates have years of experience in cell biology, high-content cell analysis, microscopy, and imaging. BD is a global business offering exceptional regional support to our customers worldwide. Here is a summary of some of our support and training capabilities.

Technical and Training Support

(23)

BD Pathway Hardware Options

description qty cat.no.

Gantry glass panel set (black) each 341047

Microscope slide holder each 341045

Replacement BD Pathway emission filter wheel each 341041

Replacement BD Pathway dichroic filter wheel each 341042

Replacement BD Pathway excitation A filter wheel each 341043 Replacement BD Pathway excitation B filter wheel each 341044 Power conditioner/convertor - (non-U.S.)

must specify country and voltage requirements each 346547

HB0 103 Mercury arc lamp replacement bulbs each 341032

Robotics Integration Package each 341046

Includes automated door, nested tip holder, Automation Software Integration Kit**

** must indicate for which robotics option: Thermo CRS Polara requires additional purchase of Polara adaptor from Thermo CRS

Robotics tip tray each 341040

Additional BD Pathway software license each 341037

Additional on-site training 1 day 341062

Custom filters and configuration inquire

Extended Service Contract year 341061

BD Pathway Optional Software

description qty cat.no.

BD Pathway Software Online - Included with BD Pathway system 1 seat 341037

BD Pathway Software Offline 3 seats 341038

BD Image Data Explorer 4 seats 341039

Neurite Outgrowth with Tube Formation Algorithm 4 seats 346203

BD IPLab for BD Pathway system 4 seats 340989

BD Pathway Additional Objectives

description qty cat.no.

Olympus PLAPO2X objective

(Plan Apochromat; NA 0.08; 6.20 mm WD) each 341052

Olympus UPLAPO4X objective

(Plan Apochromat; NA 0.16; 13.0 mm WD) each 341053

Olympus UPLFL4X objective

(Universal Plan Fluorite; NA 0.13; 17.0 mm WD; 2.9 x 1.6 mm xyFOV) each 341054 Olympus UPLFL10X objective

(Universal Plan Fluorite; NA 0.3; 10.0 mm WD; 640 x 840 µm xyFOV) each 341055 Olympus UPLAP10X objective

(Universal Plan Apochromat; NA 0.4; 3.1 mm WD; 640 x 840 µm xyFOV) each 341056 Olympus UAPO20X/340 objective

(Universal Apochromat; NA 0.75; 0.55 mm WD; 420 x 320 µm xyFOV) each 341034 NOTE: delivered with BD Pathway

Olympus LCPLFL20X objective

(Semi-Plan Apochromat; NA 0.4; 6.9 mm WD) each 341067

Note: Long working distance lens Olympus UAPO40X/340 objective

(Universal Apochromat; NA 0.9; 0.2 mm WD; 210 x 155 µm xyFOV) each 341033 Olympus PLAPO40X objective

(Plan Apochromat; NA 0.95; 0.13 mm WD) each 341057

Olympus PLAPO60X objective

(Plan Apochromat; NA 1.4; 0.15 mm WD) each 341066

Bioimaging Systems Products

description qty cat.no.

BD Pathway 855 each 341036

Includes: Imager with binoculars, on-board liquid handling, confocal, standard filter set, Pentium IV computer, 24" LCD monitor, BD Pathway software (1 license), Olympus 20X/340 objective, Slide holder, installation and training (2 days).

NOTE: gantry glass panels/doors must be specified for each BD Pathway 855 quotation

BD Pathway 435 each 641250

Includes: Bioimager, confocal, alignment-free long-life light source, standard filter set, Pentium IV computer, 20" wide-aspect ratio LCD monitor, BD Pathway software (1 license), Olympus 20X/340 objective

Ordering Information

Instrumentation and Accessories

(24)

Asia Pacific BD Singapore Tel 65.6861.06 Fax 65.6860.15

United States BD Biosciences

Customer/Technical Service Toll Free 877.22.85 Bioimaging Systems Toll Free 800.245.2614 Fax 01.40.775 Discovery Labware Fax 78.01.74 Immunocytometry Systems Fax 800.25.67 Pharmingen Fax 800.25.67 bdbiosciences.com Australia/New Zealand

Australia

Toll Free: 1800 656 100 Tel 61.2.8875.7000 Fax 61.2.8875.7200 bd_anz@bd.com New Zealand Toll Free: 0800 572.468 Tel 64..574.2468 Fax 64..574.246 bd_anz@bd.com

Japan

Nippon Becton Dickinson Toll Free 0120.8555.0 Tel 81.24.5.5405 Fax 81.24.5.5761 Europe

Belgium Tel 2.5.720.550 Fax 2.5.720.54

customer_service_bdbelgium@europe.bd.com

Canada BD Biosciences Toll Free 888.25.0187 Tel 05.542.8028 Fax 888.22.18 canada@bd.com

Regional Offices

Local Offices and Distributors

BD Biosciences 10975 Torreyana Road San Diego, CA 92121-1106 Toll free 800.245.2614 bdbiosciences.com

presorted standard uspostage

paid

sanleandro, ca permitno. 169 Argentina/Paraguay/Uruguay

Toll Free: 0800.444.552 Tel 54.11.4551.7100 Fax 54.11.4551.7400 crc_argentina@bd.com Austria

Tel 4.1.706.6.60.20 Fax 4.1.706.6.60.11 customerservice.bdb.at@europe.bd.com Brazil

Toll Free: 0800.771.7157 Tel 55.11.5185.5 Fax 55.11.5185.85 biosciences@bd.com.br Belgium Tel 2.2.400.8.5 Fax 2.2.401.70.4 help.biosciences@europe.bd.com

CCA (Caribbean/Central America) Tel 52.55.5.818

Fax 52.55.5.86 caribbean_customers@bd.com centralamerica_customers@bd.com Chile

Tel 56.2 482.7800 x16 Fax 56.2 482.7802 China

Tel 8610.6418.1608 Fax 8610.6418.1610 Colombia

Tel 57.1.572.4060 x244 / 258 Fax 57.1.572.650 / 4250 Denmark

Tel 45.4.4.45.66

Fax 45.4.4.41.66 bdbnordic@europe.bd.com East Africa Tel 254.2.41157 Fax 254.2.41161 bd@africaonline.co.ke Eastern Europe Tel 4.6221.05.161 Fax 4.6221.05.418 bdb.ema@europe.bd.com Egypt

Tel 202.268.0181 Fax 202.266.7562 Finland

Tel 58..88.70.782 Fax 58..88.70.7817 bdbnordic@europe.bd.com France

Tel .4.76.68.6.0 Fax .4.76.68.5.06 customerservice.bdb.france@europe.bd.com Germany

Tel 4.6221.05.551 Fax 4.6221.0.60 customerservice.bdb.de@europe.bd.com Greece

Tel 0.1.40.77.41 Fax 0.1.40.77.40 Hong Kong Tel 852.2575.8668 Fax 852.280.520 Hungary Tel 6.1.45.700 Fax 6.1.45.70

bdb.ema@europe.bd.com India

Tel 1.124.28.566.70 Fax 1.124.28.225 Indonesia Tel 62.21.577.120 Fax 62.21.577.125 Italy

Tel .02.48.240.1 Fax .02.48.20..6 Korea

Tel 822.404.700 Fax 822.557.4048 Malaysia Tel 60.7725.5517 Fax 60.7725.4772 Mexico

Toll Free: 01.800.26.254 Tel 52.55.5.826 Fax 52.55.5.8288 bioscienciasmexico@bd.com Middle East Tel 71.4.7.5.25 Fax 71.4.7.5.51 bdb.ema@europe.bd.com The Netherlands Tel 1.20.582.4.20 Fax 1.20.582.4.21

customer_service_bdholland@europe.bd.com North Africa

Tel .4.76.68.5.0 Fax .4.76.68.5.44 bdbiosciences_maghreb@europe.bd.com

Norway Tel 47.7.5.12.00 Fax 47.7.5.12.01 norge@europe.bd.com Pakistan Tel 2.42.5718051 Fax 2.42.5718056 bdb_pak@bd.com Peru/Bolivia/Ecuador Tel 51.1.712.0160 Fax 51.1.712.0165 Philippines Tel 62.815.881 Fax 62.815.6644 Poland

Tel 48.22.651.75.88 Fax 48.22.651.75.8 bdb.ema@europe.bd.com Portugal Enzifarma Tel 51.21.421..0 Fax 51.21.421..

South Africa Tel 27.11.60.2620 Fax 27.11.804.0544 / 46 bdb.ema@europe.bd.com Spain

Tel 4.02.27.17.27 Fax 4.1.848.81.04

Sweden Tel 46.8.775.51.10 Fax 46.8.775.51.11 bdbnordic@europe.bd.com Switzerland Tel 41.61.485.22.22 Fax 41.61.485.22.00 customerservice.bdb.ch@europe.bd.com Taiwan

Tel 8862.2722.5660 Fax 8862.2725.1768 Thailand Tel 662.646.1800 Fax 662.646.1801 Turkey

Tel 0.212.28.2720 Fax 0.212.28.270 bdb.ema@europe.bd.com United Kingdom & Ireland Tel 44.1865.78.16.88 Fax 44.1865.78.16.27 BDUK_CustomerService@europe.bd.com Venezuela

Tel 58.212.241.412 x248 Fax 58.212.241.78 West Africa Sobidis

Tel 225.20..40.2 Fax 225.20..40.28

參考文獻

相關文件

Category C contains provisions that a developing country Member or a least developed country Member designates for implementation on a date after a transitional period of time following