第五章 結論與建議
第二節 建議
建議一
鋼結構火害實驗進行前之規劃與試體破壞評估:立即可行之建議 主辦機關:內政部建築研究所
協辦機關:
利用虛擬之複合爐結合 FDS 與結構分析軟體,可建構完整對於火災-結 構(Fire- Structure)分析介面與整合,對於實驗進行前之規劃與試體破壞 情形,得以先行分析得知,予以設計妥適安全設備(如適當側撐等),以維 護試驗進行與爐體設備安全。
建議二
側板式梁柱耐震接頭火害行為研究:中長期建議 主辦機關:內政部建築研究所
協辦機關:
側板式梁柱耐震接頭設計於接頭區所造成之遮蔽效應,接頭鋼梁溫度 明顯低於一般接頭,其破壞模式亦如預期發生於遠離接頭區,避免無法發 揮原有之韌性之行為,而經分析比對一般接頭與側板接頭火害行為可發 現,不論在梁端點變形或梁柱相對轉角上,不僅符合耐震要求,更可提升 結構耐火時效。因此,該接頭之具體實驗規劃與進行有其研究價值。
參考書目
Banovic,S.W.,McCowan,C.N.,and Luecke,W.E.,“PhysicalPropertiesofStructural Steels, Federal Building and Fire Safety Investigation of the World Trade Center Disaster,”NationalInstituteofStandardsand Technology,2005.
Duthinh, D., McGrattan,K.,Khaskia,A.,“Recentadvancesin fire-structureanalysis”, Fire Safety Journal, Vol.43, pp.161-167, 2008.
Eurocode 3, “Design of Steel Structures-Part1.2:General rules-Structural Fire Design.”(ENV1993-1-2), 1995.
Forney,G.P.,“User’sGuideforSmokeview Version 5- A Tool for Visualizing Fire DynamicsSimulation Data”,NIST,2008.
Gardner L., and Ng K.T., ”TemperatureDevelopmentin StructuralStainlessSteel SectionsExposed to Fire.”FireSafety Journal,Vol.41,pp.185-203, 2006.
Jowsey, A., Torero,J.L.,Usmani,A.,“Modelling ofStructuresin Fire:an Example oftheBoundary Condition”,ProceedingsofTheInternationalTechnicalCongresson Computational Simulation Fire Models in Engineering and Research, Santander (Spain), pp. 297-313, 2004.
Liu,T.C.H.,Fahad,M.K.,and Davies,J.M.,“ExperimentalInvestigation of Behavior ofAxially Restrained SteelBeam in Fire,”JournalofConstructionalSteelResearch, Vol. 58, pp. 1211-1230, 2002.
McGrattan,K.,Klein,B.,Hostikka,S.,Floyd,J.,“FireDynamicsSimulator(Version 5)User’sGuide”,NIST,2008.
McGrattan, K., Hostikka, S., Floyd, J., Baum, H., Rehm, R., Mell, W., McDermott, R.,“FireDynamicsSimulator(Version 5)TechnicalReferenceGuide”,NIST,2008.
Wickstrom, U., Duthinh, D., McGrattan, K., “Adiabaticsurface temperature for calculating heattransferto fireexposed structures”,Interflam 2007,London,England, September 3-5, 2007, pp.943.
Wickstrom, U., “Adiabatic Surface Temperature and the Plate Thermometer for Calculating Heat Transfer and Controlling Fire Resistance Furnaces”, Fire Safety Science, Proceedings of the Ninth International Symposium, pp 1227-1238, 2009.
林誠興,「建築物火災行為與結構安全之性能模擬分析」,行政院國家科學委員 會專題研究計畫成果報告,2006。
林誠興、王士承,「數值模擬技術應用於建築物火災情境重現之探討」,工業安 全科技,pp46-53,2007。
附錄-期末審查意見
為?或火害後鋼結構之殘餘強度?或
及構架型態等參數對鋼構強度之影響。
陳組長建忠
(1)研究所提平板測溫計之「使用限制」,是 研究所撰,亦或文獻整理而來,如是前 者,已有具體發現,宜詳細整理,以免 國際防火研究一再誤用。
(2)請多研提研究課題提案單以及研究計 畫,以供各「個案中綱計畫」之分年研 究計畫規劃之參考。
研究中所提之限制係參考國外文獻而來,並 輔以本案實驗成果所得。
遵照辦理