在本文中為了提升系統的訊雜比我們將磁通轉換線圈的輸入線圈 匝數做最佳化,並有效的將系統的訊雜比提高了 16.2 %。接著我們做 了預極化磁場切換電路的改良,使預極化線圈能提供更高的極化磁場 使樣品極化率提高,藉此提升樣品訊號強度與訊雜比,而我們也成功 的驗證在同樣品下,極化場 1197 高斯與原先系統 684 高斯的訊號訊 雜比上提高了 109 %。在造影成像上我們利用去離子水的樣品之一維 影像頻譜圖與造影結果驗證我們的成像品質在訊雜比上也有明顯的 提升。在成像解析度上我們也利用不同高度水柱來證明我們的系統在 三個維度都能夠達到 2 mm 的解析度。最後隨著本研究的改進,而總 合以上成果都將更有利於未來系統在生物及人體造影上的應用。

參考文獻

Yueh Yang, “Characterization of tumors using SQUID-detected nuclear magnetic resonance and imaging”,Appl. Phys. Lett. 97, 263701 (2010)

[3] M. Goldman, H. Jo’hannesson, O. Axelsson, M. Karlsson,

“Hyperpolarization of 13C through order transfer from parahydrogen:

A new contrast agent for MRI ”,Magn.Reson. Imaging 23, 153 (2005) [4] G. Navon, Y.-Q. Song, T. Ro˜o˜m, S. Appelt, R.E. Taylor, A. Pines,”

Enhancement of Solution NMR and MRI with Laser-Polarized Xenon”, Science 271, 1848 (1996).

[5] S. Appelt, F.W. Ha‥sing, S. Baer-Lang, N.J. Shah, B. Blümich,

“Enhancement of Solution NMR and MRI with Laser-Polarized Xenon”, Chem. Phys. Lett. 348, 263 (2001)

[6] Shu-Hsien Liao and Herng-Er Horng, Hong-Chang Yang, and Shieh-Yueh Yang, “Longitudinal relaxation time detection using a high-Tc superconductive quantum interference device magnetmeter”,J.

Appl. Phys. 102, 033914 (2007).

[7] M.A. Espy, A.N. Matlachov, P.L. Volegov, J.C. Mosher, and R.H.Kraus Jr., ” SQUID-Based Simultaneous Detection of NMR and Biomagnetic Signals at Ultra-Low Magnetic Fields”, IEEE

Trans.Appl. Supercon. 15, 635 (2005).

[8] A.H. Trabesinger, R. McDermott, S.K. Lee, M. Mu1ck, J. Clarke, and A. Pines, “ SQUID-Detected Liquid State NMR in Microtesla Fields“, J. Phys. Chem. A 108, 957-963 (2004).

[9] R. McDermott, S.K. Lee, B. ten Haken, A.H. Trabesinger, A. Pines, and J. Clarke, “Microtesla MRI with a superconducting quantum interference Device”, Proc. Natl. Acad. Sci. USA 101, 7857 (2004).

[10] M. Mössle, S. Busch, M. Hatridge, W. Myers, A. Pines, and J. Clarke,

“SQUID-detected microtesla MRI: a new modality for tumor detection”, paper presented at 2006 Applied Superconductivity conference, Aug. 27-Sept.1, 2006, Seattle, Washington, USA.

[11] Y. S. Greenberg, “Application of superconducting quantum interference devices to nuclear magnetic resonance,” Rev. Mod. Phys.,

Trahms,“Liquid state nuclear magnetic resonance at low fields using a nitrogencooled superconducting quantum interference device,” Appl.

Phys. Lett.,vol. 90,182503(2007)

[14] K. Schlenga, R. McDermott, J. Clarke, R. E. de Souza, A. Wong-Foy, and A. Pines, “Low-field magnetic resonance imaging with a high- Tc dc superconducting quantum interference device,” Appl. Phys. Lett., vol. 75,3695(1999)

Yang, “Enhancement of nuclear magnetic resonance in microtesla magnetic field with prepolarization field detected with high-Tc superconducting quantum interference device,” Appl. Phys. Lett., vol.

88,252505( 2006.)

[16] M. Burghoff, S. Hartwig, L. Trahms, and J. Bernarding, “Nuclear magnetic resonance in the nanoTesla range,” App. Phys. Lett., vol. 87, 054103(2005.)

[17] L. Qiu, Y. Zhang, H. J. Krause, A. H. Braginski, M. Burghoff, and L.

Trahms, “Nuclear magnetic resonance in the earth’s magnetic field using a nitrogen-cooled superconducting quantum interference device,”Appl. Phys. Lett., vol. 91, 072505(2007.)

[18] S. H. Liao, H. E. Horng, H. C. Yang, and S. Y. Yang, “Longitudinal relaxation time detection using a high-Tc superconductive quantum interference device magnetometer,” J. Appl. Phys., vol. 102, high-Tc superconducting quantum interference devices in magnetic fields as low as microteslas,” Supercond. Sci. Technol., vol.

22,045008(2009)

[21] S. H. Liao, H. C. Yang, H. E. Horng, and S. Y. Yang,

“Characterization of magnetic nanoparticles as contrast agents in magnetic resonance imaging using high-Tc superconducting quantum interference devices in microtesla magnetic fields,” Supercond. Sci.

Technol., vol. 22, 025003(2009).

[22] H. C. Seton, J.S.M. Hutchison, D. M. Busell, “A 4.2 K receiver coil and SQUID amplifier used to improve the SNR of low-field magnetic resonance images of the human arm”,Meas. Sci. Technol.

8, 198 (1997).

[23] S. Kumar, R. Mathews, S. G.. Haupt, D.K. Lathrop, M. Takigawa, J.

R. Rozen, S. L. Brown, R. H. Koch, “Nuclear magnetic resonance using a high temperature superconducting quantum interference device”Appl. Phys. Lett. 70, 1037 (1997).

[24] S. Kumar, W. F. Avrin, B. R. Whitecotton, “NMR of room temperature samples with a flux-locked dc SQUID” IEEE Trans.

Magn. 32, 5261 (1996).

[25] K. Schlenga, R. F. McDemott, J. Clarke, R. E. de Souza, A.

Wong-Foy, A. Pines, “Low-Field Magnetic Resonance Imaging with a High-Tc dc Superconducting Quantum Interference Device,” Appl.

Phys. Lett. 75, 3695 (1999).

[26] N. Q. Fan, M. B. Heaney, J. Clarke, D. Newitt, L. L. Wald, E. L.

Hahn, A. Bielecki, A. Pines, “Nuclear magnetic resonance with DC SQUID preamplifiers”IEEE Trans. Magn, vol. 25,1193(1989)

[27] M. A. Espy, A. N. Matlachov, P. L. Volegov, J. C. Mosher, and R. H.

Kraus, Jr. “SQUID-based simultaneous detection of NMR and biomagnetic signals at ultra-low magnetic fields” IEEE Trans. Appl.

Supercon. 15, 635 (2005).

[28] M. Burghoff, S. Hartwig, L. Trahms, and J. Bernarding, “Nuclear

magnetic resonance in the nanoTesla range”,Appl. Phys. Lett. 87, 054103 (2005)

[29] W. Myers, D. Slichter, M. Hatridge, S. Busch, M. Mößle, R.

McDermott,A. Trabesinger, and J. Clarke, “Calculated signal-to-noise ratio of MRI detected with SQUIDs and Faraday

[32] Joseph P. Hornak, Ph.D. (1996-2011),The Basics of MRI, 2013 年 7 月 3 日取自於 http://www.cis.rit.edu/htbooks/mri/ for SQUID NDE"INSTITUTE OF PHYSICS PUBLISHING,

Supercond. Sci. Technol. 17 (2004)

誌謝

我是某某某領域的 Master。