• 沒有找到結果。

Chapter 6 Conclusion

6.2. Future Work

This system compare to the enterprise medical application is not yet mature, so the doctors still cannot get used to it and diagnose with this system. If we can add more function to it such as more medical analysis method to meet doctor’s requirement, it could be more widely used in medical application. Though stereoscopic idea is easy but how to adjust it to get the biggest 3D effect without viewer getting uncomfortable is still a big issue. Parallax is limited by viewer’s eye separation and their brain. In fact, not everyone can get used to this 3D effect.

Though NVIDIA’s 3D vision allow user to enjoy 3D experience of games and movies easily, but it is not very friendly to individual developers. If we could have more

59

control of 3D display and develop our own system with 3D effect, it will be much easier to do extra medical implementation.

60

Reference

[1] M. Agus, F. Bettio, A. Giachetti, E. Gobbetti, J.A.I. Guitián, F. Marton, J. Nilsson and G. Pintore, "An interactive 3D medical visualization system based on a light field display," The Visual Computer, vol. 25, no. 9, pp. 883-893, 2009.

[2] 2012. [Online]. Available: http://www.cognitiveatlas.org/term/binocular_vision.

[3] C. Wheatstone, "Contributions to the physiology of vision.—Part the First. On some remarkable, and hitherto unobserved, phænomena of binocular vision.," Phil. Trans. R.

Soc. Lond., vol. 128, no. 0, p. 371–394, Jan. 1838.

[4] A. N. Cherniy, B. M. Kanter, E. V. Serova and G. V. Ratobyl’skii, "Use of stereoscopic vision for analysis of digital X-ray images of lungs.," Biomedical Engineering, vol. 41, no. 5, 214-217 2007.

[5] D. V. S. X. De Silva, W. A. C. Fernando, S. T. Worrall, S. L .P. Yasakethu and A. M.

Kondoz, "Just Noticeable Difference in Depth Model For Stereoscopic 3D Displays,"

in IEEE Int. Conf. on Multimedia & Expo, 2010.

[6] X. H. Wang, W. F. Good, C. R. Fuhrman, et al., "Stereo CT image compositing methods for lung nodule detection and characterization.," Acad Radiol, vol. 12, p.

1512–1520, 2005.

[7] X. H. Wang, J. E. Durick, A. Lu, D. L. Herbert, S. K. Golla, K. Foley, C. S. Piracha, D. D. Shinde, B. E. Shindel, C. R. Fuhrman, C. A. Britton, D. C. Strollo, S. S. Shang, J. M. Lacomis and W. F. Good, "Characterization of Radiologists’ Search Strategies for Lung Nodule Detection: Slice-Based Versus Volumetric Displays," Journal of Digital Imaging, vol. 211, pp. S39-S49, 2008.

[8] X. H. Wang, J. E. Durick, A. Lu, D. L. Herbert, C. R. Fuhrman, J. M. Lacomis, C. A.

Britton, D. C. Strollo, S. S. Shang, S. K. Golla and W. F. Good, "Compare Display Schemes for Lung Nodule CT Screening," Journal of Digital Imaging, vol. 24, no. 3, pp. 478-484, 6 2011.

[9] A. P. Santhanam, T. R. Willoughby, I. Kaya, A. P. Shah, S. L. Meeks, J. P. Rolland and P. A. Kupelian, "A Display Framework for Visualizing Real-Time 3D," Journal of

61

Display Technology, vol. 4, no. 4, 12 2008.

[10] T. R. Nelson, E. K. Ji, J. H. Lee, M. J. Bailey and D. H. Pretorius, "Stereoscopic evaluation of fetal bony structures.," J Ultrasound Med, vol. 27, pp. 15-24, 2008.

[11] M. H. P. H. van Beurden, W. A. I. Jsselsteijn and J. F. Juola, "Effectiveness of Stereoscopic Displays in Medicine: A Review," 3D Research, vol. 3, no. 1, pp. 1-13, 3 2012.

[12] R. Kickuth, G. Hartung, U. Laufer, C. Gruening, C. Stueckle, D. Liermann and J.

Kirchner, "Stereoscopic 3D CT vs standard 3D CT in the classification of acetabular fractures: an experimental study," The British Journal of Radiology, vol. 75, p. 422–

427, 2002.

[13] A. Hernandez, O. Basset, A. Bremond and I. E. Magnin, "Stereoscopic visualization of three-dimensional ultrasonic data applied to breast tumours," European Journal of Ultrasound, vol. 8, p. 51–65, 1998.

[14] T. Yamagishi, K. Abe, and K. H. Höhne, "Three-dimensional stereoscopic abdominal CT angiography as an educational tool for medical students," in International Congress Series 1268, 2004.

[15] T. Moll, P. Douek, G. Finet, F. Turjman, C. Picard, D. Revel and M. Amiel, "Clinical assessment of a new stereoscopic digital angiography," Card Vasc Interv Radiol, vol.

21, pp. 11-16, 1998.

[16] A. E. Rosenbaum, W. Huda, K. A. Lieberman and R. D. Caruso, "Binocular three-dimensional perception through stereoscopic," Acad Radiol, vol. 7, pp. 21-26, 2000.

[17] K.U.Wentz, H.P. Mattle, R.R. Edelman, J. Kleefield, G.V. O’Reilly, C. Liu and B.

Zhao, "Stereoscopic display of MR angiograms," Neuroradiology, vol. 33, p. 123–125, 1991.

[18] M. M. Goodsitt, H. P. Chan, K. L. Darner et al., "The effects of stereo shift angle, geometric magnification and display zoom on depth measurements in digital stereomammography.," Med Phys, vol. 29, p. 2725–2734, 2002.

[19] H. P. Chan, M. M. Goodsitt, M. A. Helvie, et al., "ROC study of the effect of stereoscopic imaging on assessment of breast lesions.," Med Phys, vol. 32, p. 1001–

62

1009, 2005.

[20] T. L. Gautsch, E. E. Johnson and L. L. Seeger, "True threedimensional stereographic display of 3D reconstructedCT scans of the pelvis and acetabulum.," vol. 305, p. 138–

51, 1994.

[21] A. Abildgaard, A. K.Witwit, J. S. Karlsen, E. A. Jacobsen, B. Tennøe, G. Ringstad and P. Due-Tønnessen, "An autostereoscopic 3D display can improve visualization," Int.

Journal of Computer Assited Radiology and Surgery, vol. 5, pp. 549-554, 2010.

[22] 2012. [Online]. Available: http://medical.nema.org/Dicom/about-DICOM.html.

[23] H. C. Hu, "Inter-Subject Human Lung Non-Rigid Registration with Weighted Intensity and Landmark Cost Function," 2011.

[24] J. M. Wallis and T. R. Miller, "Three-dimensional display in nuclear medicine," in IEEE Trans Med Imaging, Lerner CA, Kleerup EC, 1989.

[25] J. M. Wallis and T. R. Miller, "Volume rendering in three-dimensional display of SPECT images," J. Nucl. Med., vol. 31, no. 8, p. 1421–8, 1 August 1990.

[26] J. M. Wallis and T. R. Miller, "Three-dimensional display in nuclear medicine and radiology," vol. 32, no. 3, p. 534–46, March 1991.

[27] P. Masa-Ah, M. Tuntawiroon and S. Soongsathitanon, "A novel scheme for Standardized Uptake Value (SUV) calculation in PET scans," Int. Journal of Mathematical Models and Methods in Applied Sciences, vol. 4, no. 4, pp. 291-299, 2010.

[28] P. Masa-Ah and S. Soongsathitanon, A Novel Standardized Uptake Value (SUV) Calculation of PET DICOM Files Using MATLAB, V. M. a. Z. B. E. Mastorakis, Ed., Taipei: WSEAS Press, 2010, pp. 413-416.

[29] Y. Zhu and T. Zhen, "3D Multi-View Autostereoscopic Display and Its Key Technologie," in Asia-Pacific Conf. on Information Processing, 2009.

[30] D. Kim and K. Sohn, "Depth Adjustment For Stereoscopic Image Using Visual Fatigue Prediction and Depth-Based View Synthesis," in IEEE Int. Conf. on Multimedia & Expo, 2010.

[31] V. Ramos-Diaz, E. Cruz-Irisson, M. Nino-de-Rivera and L. Ponomaryov, "3D color

63

video conversion from 2D video sequence using stereo matching technique," in IEEE Int. Midwest Sympo. on Circuits and Systems, Cancun, 2009.

[32] O. Fumio, S. Takayuki, H. Takenori, K. Yoshihiko and K. Syouichi, "Application of PC Stereoscopic Image Viewer for Informed Consent," in Proc. of the Fourth Int.

Conf. on Computer and Information Tech., Wuhan, China, 2004.

[33] L. M. Su, B. P. Vagvolgyi, R. Agarwal, C. E. Reiley, R. H. Taylor and G. D. Hager,

"Augmented Reality During Robot-assisted Laparoscopic Partial Nephrectomy:

Toward Real-Time 3D-CT to Stereoscopic Video Registration," Urology, vol. 73, no.

4, pp. 896-900, April 2009.

[34] M. Kersten, J. Stewart, N. Troje and R. Ellis, "Enhancing Depth Perception in Translucent Volumes," IEEE Transactions on Visualization and Computer Graphics, vol. 12, no. 5, pp. 1117-1123, 2006.

[35] L. Bouguila, M. Ishii and M. Sato, "Effect of Coupling Haptics and Stereopsis on Depth Perception in Virtual Environment," in Proceedings of the 1st Workshop on Haptic Human Computer Interaction, Glasgow, Scotland, 2000.

[36] Y. Shunsuke, M. Shinya, H. Toshihito, et al., "A Technique for Precise Depth Representation in Stereoscopic Display," in Proceedings of the International Conference on Computer Graphics, Alberta, Canada, 1999.

[37] L. Lin, P. Wu, J.Huang and J. Li, "Precise Depth Perception in Projective Stereoscopic Display," in The 9th International Conference for Young Computer Scientists, 2008.

[38] H. Liao, N. Hata, M. Iwahara, I. Sakuma and T. Dohi, "High-resolution autostereoscopic surgical display," in Engineering in Medicine and Biology, 2002.

24th Annu. Conf. and the Annu. Fall Meeting of the Biomedical Engineering Society EMBS/BMES Conf., 2002. Proc. of the 2nd Joint, Houston.

[39] H. Liao, N. Hata and T. Dohi, "Image-Guidance For Cardiac Surgery Using Dynamic Autostereoscopic Display System," in IEEE Transactions on Information Technology in Biomedicine, 2004.

[40] O. Svitlana, "3-D-display," in TCSET'2010, February 23-27, 2010, Lviv-Slavske, Ukraine, 2010.

64

[41] P. Gould, "Three-dimensional holograms put on a display," Materials Today, vol. 11, no. 4, pp. 9-9.

[42] W. Birkfellner, Applied Medical Image Processing: A Basic Course, Boca Raton:

CRC Press, 2011.

[43] [Online]. Available: http://www.math.utah.edu/~treiberg/Perspect/Perspect.htm.

[44] Oxford English Dictionary, "parallax, n.": Oxford University Press.

[45] Shorter Oxford English Dictionary, Mutual inclination of two lines meeting in an angle, 1968.

相關文件