This section contains a general description of your power supply as well as its performance specifications. Information about options and accessories are also provided.

The TPS-3025 series has been designed and tested according to EN-61010-1, Safety requirement for Electronic Measuring Apparatus.

1.2 Safety Considerations

SAFETY PRECAUTIONS SAFETY NOTES

The following general safety precautions must be observed during all phases of operation, service, and repair of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. The manufacturer assumes no liability for the customer’s failure to comply with these requirements.

BEFORE APPLYING POWER

Verify that the power supply is set to match the available line voltage and the correct fuse is installed.

GROUND THE INSTRUMENT

This product is provided with a protective earth terminal. To minimize shock hazard, the instrument chassis and cabinet must be connected to an electrical ground. The instrument must be connected to the AC power supply mains through a three-conductor power cable, with the third wire firmly connected to an electrical ground (safety ground) at the power outlet. For instruments designed to be hard-wired to the AC power lines (supply mains), connect the protective earth terminal to a protective conductor before any other connection is made. Any interruption of the protective (grounding) conductor or disconnection of the protective earth terminal will cause a potential shock hazard that could result in personal injury. If the instrument is to be energized via an external autotransformer for voltage reduction, be certain that the autotransformer common terminal is connected to the neutral (earthed pole) of the AC power lines (supply mains).

The RS232 (option) Ground is connected with chassis ground, and therefore the operator must take care if the computer is also connected with other measuring devices prevent a short cut.

FUSES

Only fuses with the required rated current, voltage, and specified type (normal blow, time delay, etc.) should be used. Do not use repaired fuses or shout circuited fuseholders. To do so could cause a shock or fire hazard.

DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE

Do not operate the instrument in the presence of flammable gases or fumes.

KEEP AWAY FROM LIVE CIRCUITS

Operating personnel must not remove instrument covers. Component replacement and internal adjustments must be made by qualified service personnel. Do not replace components with power cable connected.

!

Under certain conditions, dangerous voltages may exist even with power cable removed. To avoid injuries, always disconnect power, discharge circuits and remove external voltage sources before touching components.

DO NOT SERVICE OR ADJUST ALONE

Do not attempt internal service or adjustment unless another person, capable of rendering first aid and resuscitation, is present.

DO NOT EXCEED INPUT RATINGS

This instrument must be connected to a properly grounded receptacle to minimize electric shock hazard. Operate at line voltages or frequencies in excess of those stated on the data plate may cause leakage currents in excess of 5.0mA peak.

SAFETY SYMBOLS

WARNING The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the like, which, if not correctly performed or adhered to, could result in personal injury. Do not proceed beyond a WARNING sign until the indicated conditions are fully understood and met.

CAUTION The CAUTION sign denotes a hazard. It calls attention to a procedure, practice, or the like, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the product. Do not proceed beyond a CAUTION sign until the indicated conditions are fully understood and met.

Chassis ground symbol

Protective Conductor terminal

Caution, risk of electric shock

DO NOT SUBSTITUTE PARTS OR MODIFY INSTRUMENT

Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification to the instrument. Return the instrument to a qualified dealers for service and repair to ensure that safety features are maintained.

INSTRUMENTS WHICH APPEAR DAMAGED OR DEFECTIVE SHOULD BE MADE INOPERATIVE AND SECURED AGAINST UNINTENDED OPERATION UNTIL THEY CAN BE REPAIRED BY QUALIFIED SERVICE PERSONNEL.

!

1.3 Options

Options 01 determine which line voltage is set at the factory. This information is on the rear panel label.

Option 01: 230 (240) Vac AC Input Option 02: Rack mount Shelf

1.4 Accessories

Power cable

Operation manual

Fuse 1.5 Output Isolation

The output of the power supply is isolated from earth ground. Either output terminal may be grounded or the output may floated up to +/- 240 Vdc (including output voltage) from chassis ground

1.6 Specifications

TRIPLE OUTPUT LINEAR POWER SUPPLY UP TO 165 WATTS

Model LPS-305

MAX. OUTPUT POWER 165 WATTS

OUTPUT VOLTAGE

Output Voltage 0 to +30V / 0 to -30V Fixed 3.3V / 5V

Setting Resolution 10mV

Max. output voltage +32V / -32V

Dual tracking 0 to ±30V

Tracking deviation ±20mV

OUTPUT CURRENT

Output Current 0 to +2.5A / 0 to -2.5A 3A

Setting Resolution 1mA

Max. output current +3A / -3A Current limited approx. 3.3A

Dual tracking 0 to ±2.5A

Tracking deviation ±5mA

CONSTANT VOLTAGE CHARACTERISTICS (at rated output)

Line regulation(for change of AC ±10%) 1mV 5mV

Load regulation(for load change 0 100%) 2mV 10mV

Ripple/Noise rms (10Hz to 20MHz) 1.5mVrms 2mVrms

Ripple/Noise peak (10Hz to 20MHz) 10mVp-p 20mVp-p

Transient Response 200μs Typical

Temperature Coefficient 100ppm / ℃ Typical

CONSTANT CURRENT CHARACTERISTICS (at rated output : ±2.5A ) Line regulation (for change of AC ±10% ) 15mA Typical

Load regulation (for change from short to

full load ) 10mA Typical

Ripple/Noise rms (10Hz to 20MHz) 1mArms Typical Ripple peak (p-p)(10Hz to 20MHz) 5mAp-p Typical

Temperature Coefficient 200 ppm / ℃ Typical

Display 2×16 LCD with backlit; Front Panel Status

Announciators with beeper

Voltage Accuracy ±( 0.2% of rdg +2 digits ) ± 2%

Current Accuracy ±( 0.5% of rdg +5 digits )

Common Mode Voltage ±240Vdc

Temperature ranges Operating: 0℃ to 40℃, less than 80% RH;

Storage: -40℃ to 70℃, less than 80% RH Dimensions (W × H × L) 8.4" × 5.2" × 15.7"

Weight Approx. 18 lbs

Cooling Fan Cooled

Power Source AC 115V ± 10% OR 230V ± 10%, 47 to 63Hz

Current Consumption 2.88A / AC 115V or 1.48A / AC 230V

Fuse Rating 5AT / 250V for AC 115V, 2.5AT / 250V or AC 230V

Options Opt 01 [ 230 ( 240 ) Vac; factory-installable only ]

Accessories User’s manual, power cord, fuse

*For output less than 5% of rated output, add 5 digits to the accuracy specification

RS232 Interface capabilities:

1. RS232C DCE interface: 9-pin D-SUB connector.

2. Port configuration: asynchronous 2400 baud, 8 data bits, 1 stop bits, no parity.

2. INSTALLATION