• 沒有找到結果。

Comparisonofdigitalpanoramicradiographyversusconebeamcomputerizedtomographyformeasuringalveolarbone RESEARCHOpenAccess

N/A
N/A
Protected

Academic year: 2022

Share "Comparisonofdigitalpanoramicradiographyversusconebeamcomputerizedtomographyformeasuringalveolarbone RESEARCHOpenAccess"

Copied!
7
0
0

加載中.... (立即查看全文)

全文

(1)

R E S E A R C H Open Access

Comparison of digital panoramic radiography versus cone beam

computerized tomography for measuring alveolar bone

Zunan Tang1,2, Xianchu Liu1,2and Kejia Chen1,2*

Abstract

Background: Cone beam computerized tomography (CBCT) has been widely used in dental implanting. However, the local hospitals usually don’t have access to CBCT due to the cost and medical investment, especially in West of China. The doctors in local hospitals have to make reasonable dental planting using orthopantomography (OPG) to reduce risks. Therefore, it is clinically meaningful to determine the magnification rate of OPG to obtain correct diagnosis. This study investigated the magnification rate of OPG in measuring different maxillofacial loci compared with CBCT.

Methods: Eighty-six patients demanding dental implanting were scanned by CBCT and OPG. The vertical distance between the alveolar ridge crest of the maxillary first molar and the sinus bottom of the upper jaw, the distance between the alveolar ridge crest of the mandibular first molars and the top of nerviduct in the mandibular alveolar, and the distance between the alveolar ridge crest of the maxillary central incisors and the bottoms of the nasal cavities were measured. The horizontal distance in those loci were also measured. The distances derived from CBCT were used as reference. The distances between the two methods were compared using paired t-test. The

magnification rates at these positions were calculated. The relationship between the data acquired from the two methods was analyzed Pearson correlation.

Results: The correlation coefficients (R) between the paired samples obtained from OPG and CBCT were highly related (P < 0.05) with R values varying from 0.840 and 0.959 in vertical distances and R values varying from 0.703 and 0.904 in horizontal distances. Compared with data obtained from CBCT, the mean vertical magnification rates were 11.38% and 12.95% vertically and 8.55% and 9.43% horizontally for the first molars in the right and left maxilla respectively; 7.26% and 6.35% vertically and 5.33% and 4.96% horizontally for the first molars in the right and left mandible respectively; and 5.55% and 4.84% vertically and 6.53% and 7.47% horizontally for the central incisors in the upper right and left jaws respectively.

Conclusion: The magnification rates of OPG at these teeth are different. The distances measured by OPG were highly correlated with that measured by CBCT.

Keywords: Cone beam computerized tomography, Digital panoramic radiography, Dental implanting, Magnification rate

* Correspondence:chenkejia56@163.com

1Department of Oral Radiology, Xiangya Stomatological Hospital, Central South University, No. 72 Xiangya Road, Changsha 410078, China

2School of Stomatology, Central South University, Changsha, China

© The Author(s). 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

(2)

Background

Panoramic radiography and periapical radiography are im- portant methods in dental implant planning [1, 2]. How- ever, these two-dimensional radiographs can be affected by tissue superimposition due to malocclusion deformity or other complex situations. Orthopantomography (OPG) is an important imaging method to assess vertical bone volume and detect dental caries and periodontal diseases [3]. OPG has many advantages including panoramic, easy and cheap to conduct, and informative regarding jaw morphology, bone density, etc. Therefore, OPG is one of the most common imaging methods for routine examin- ation in clinical practice [4–6].

In recent years, maxillofacial cone beam computed tomography (CBCT) has been widely used in dental implanting [7, 8], assessment of orthodontic treatment, complex alveolar surgery, oral local system reconstruc- tion and treatment of tooth and dental pulp diseases.

CBCT is advantageous in high spatial resolution, short scan time and rapid image acquisition [9–13].

With the improvement of living standards, the de- mand for dental implantation is increasing quickly. In China, it is a trend to use three dimensional imaging of high precision to replace two-dimensional imaging for stomatological diagnosis. However, due to the cost and medical investment, the local hospitals usually don’t have access to CBCT, especially in West of China. The doctors in local hospitals have to make reasonable dental planting using OPG to reduce risks. Therefore, it is clin- ically meaningful to determine the magnification rate of OPG to obtain correct diagnosis. Then, clinicians could be able to estimate the real bone measurement based on the OPG measurement and the magnification rate to ob- tain the ideal implants placement. In the present study, the data of OPG images and CBCT images from 86 pa- tients demanding dental implanting were compared and analyzed. The main endpoints were the magnification rates of OPG in measuring the vertical and horizontal distance at different maxillofacial loci.

Methods Patients

The study was approved (reference number: 20150902) by the Medical Ethics Committee of Xiangya Stomatolo- gical Hospital of Central South University and the signed informed consent was obtained from each patient.

Eighty-six patients (48 male, 38 female; 15-67 years old, mean age of 41.3), who demanded for dental implant- ation and had OPG and CBCT in Xiangya Stomatologi- cal Hospital of Central South University between July 2013 and September 2014, were enrolled in the study.

The inclusion criteria were the patients with clear OPG and CBCT images showing the bottoms of nasal cavity, maxillary sinus and inferior alveolar nerve tube, and the

patients with normal jaw and good periodontal condi- tion. The exclusion criteria were medical history of jaw lesions or jaw surgery, severe malocclusion deformity or artifacts resulted from metal denture.

Scanning methods

For OPG scanning, the patients were in standing pos- ition with cervical spine staying vertically. The lower jaw was placed in the middle of the chin support. The incisal edge of the front teeth bit on the groove of the plate.

The head was perpendicular to the ground. The angle bisector between the orbitomeatal line and acanthiomea- tal line was parallel to the ground. OPG was performed using a digital panoramic scanner (Planmeca, Promax, Finland), with the voltage of 66 kV, current of 9 mA and the minimum exposure time of 16 s. The data were saved in JPG format.

For CBCT scanning, the patients were in sitting pos- ition with cervical spine staying vertically. The sagittal laser line of the CBCT scanner (Planmeca, Promax 3D Max, Finland) was superimposed with median sagittal line of the patients. The lower jaw was placed in the middle of the chin support. Their upper and lower den- titions were at centric occlusion position. The occlusion was parallel to the ground. The patients held the handle for automatic CBCT scanning. During the scanning, the mouth kept motionless. CBCT was operated at the volt- age of 96 kV, current of 10 mA with scanning field of 10 × 9 cm using matrix of 512 × 512. The scan time was 15 s, the data was stored in Dicom format and the im- ages were reconstructed using slices of 0.15 mm and measured. All scans were performed by the radiologists with more than 3 years working experience. For the same patients, OPG and CBCT were taken on the same day.

Measurement methods

For the vertical measures, the distances (a and b) be- tween the alveolar ridges of bilateral maxillary first mo- lars (16, 26) and the bottoms of the maxillary sinus, the distance (c and d) between the alveolar ridges of bilateral mandibular first molars (36, 46) and inferior alveolar nerve canal, and the distance (e and f ) between the al- veolar ridge crest of bilateral maxillary central incisors (11, 21) and the bottoms of the nasal cavities were mea- sured. As for the horizontal measures (the implants width), the followings were measured: the distances (g and h) between the alveolar ridges of the adjacent teeth of maxillary first molars (16, 26), the distance (i and j) between the alveolar ridges of the adjacent teeth of man- dibular first molars (36, 46) and the distance (k and l) between the alveolar ridges of the adjacent teeth of max- illary central incisors (11, 21). The tomographic volumes were manually measured and analyzed with Planmeca

(3)

Romexis 3.0.1 R workstation. All measurements were taken twice by two experienced radiologists independ- ently and the mean values were used for analysis. The interclass correlation co-efficiency (ICC) was used as evaluating indicators to determine the reliability of the same observer and between observers.

For OPG, the midpoints between mesial and distal al- veolar ridges were used as the measuring points to measure the distances a1, b1, c1, d1, e1 and f1 (Fig. 1).

The distance between the mesial (15) and distal (17) al- veolar ridges of the adjacent teeth of maxillary first mo- lars (16) was measured as g1. The distance between the mesial (25) and distal (27) alveolar ridges of the adjacent teeth of maxillary first molars (26) was measured as h1.

The distance between the mesial (35) and distal (37) al- veolar ridges of the adjacent teeth of mandibular first molars (36) was measured as i1. The distance between the mesial (45) and distal (47) alveolar ridges of the adja- cent teeth of mandibular first molars (46) was measured as j1. The distance between the mesial (12, 21) alveolar ridges of the adjacent teeth of maxillary central incisors (11) was measured as k1. The distance between the me- sial (11, 22) alveolar ridges of the adjacent teeth of max- illary central incisors (21) was measured as l1.

For CBCT, the reconstructed images were rotated on the plane X (sagittal plane) and plane Y (coronal plane) to superimpose the long axis of the tooth with the obser- vational vertical scale bar. The images were rotated on the plane Z (cross-sectional plane) to make the tangent of the dental arch superimposed with the sagittal plane, and the mesial-distal tooth line superimposed with the coronal plane. The line distances a-X, a-Y, b-X and b-Y were measured from the alveolar ridge crests of the teeth 16 and 26 to the bottoms of the maxillary sinus on the planes X and Y respectively. The distances a2 and b2 were determined: a2 = (aX + aY)/2 and b2 = (bX + bY)/2.

Similarly, c2 (c2 = (cX + cY)/2), d2 (d2 = (dX + dY)/2), e2 (e2 = (eX + eY)/2), and f2 were measured (Fig. 2). On the plane X, the midpoint of the mesial-distal alveolar ridge line was used as the measuring points of the alveolar ridge. On the plane Y, the midpoint between the bucco- lingual and alveolar ridge was used as the measuring points of the alveolar ridge. The horizontal distance of g2, h2, i2, j2, k2 and l2 were measured on the CBCT images.

The magnification formula was defined as magnifica- tion rate = (a1- a2)/a2 × 100%.

Statistical analysis

All data were analyzed using SPSS 19.0 (SPSS Inc, Chicago, USA). The paired t-test was used to compare the vertical distances and horizontal distance between the two methods. P < 0.05 was considered statistically significant. The normality of data was tested using the k- w test. Pearson correlation analysis was used to analyze the relationship between the data acquired using the two methods. The correlation coefficient (R) between the paired samples was calculated and was considered highly related if R was between 0.5 and 1.

Results

The ICC value of the repeated measurements by the same observer was 0.97 and 0.95 respectively and the ICC value of the measurements by different observers was 0.93. The ICC values were above 0.8.

The correlation coefficients (R) between the paired samples obtained from OPG and CBCT were highly re- lated (P < 0.05) with R values varying from 0.840 and 0.959 in vertical distances at different teeth and R values varying from 0.703 and 0.904 in horizontal distances (Table 1). The correlations between the two sets of data are shown in Figs. 3 and 4. Compared with the data

Fig. 1 OPG image showing the measurement sites

(4)

obtained from CBCT, the mean vertical magnification rates were 11.38% and 12.95% vertically and 8.55% and 9.43% horizontally for the first molars in the right and left maxilla respectively; 7.26% and 6.35% vertically and 5.33% and 4.96% horizontally for the first molars in the right and left mandible respectively; and 5.55% and 4.84% vertically and 6.53% and 7.47% horizontally for the central incisors in the upper right and left jaws respectively.

Discussion

The present study showed different magnification rates of OPG compared with CBCT in measuring different maxillofacial loci. There were highly related correlation coefficients (R) between the paired samples obtained from OPG and CBCT.

In CBCT reconstructed 3D images, the morphology of alveolar ridge and the height of alveolar bone can be ac- curately displayed, [14, 15] showing buccolingual thick- ness, mesiodistal width, clear local bone structures and their anatomical relationship with surrounding anatomical structures, especially inferior alveolar nerve tube and the maxillary sinus. These images can assist to determine the

volume of the bone, and the position, direction and volume of the implants, which are of great value for pre- implanting planning[16, 17]. However, due to high tech- nical requirements and high cost, CBCT is not available in many local hospitals in China. OPG is widely used in local hospitals [2, 18], but it is hard to precisely determine the height of alveolar bone and the relationship between max- illary sinus and inferior alveolar nerve tube. The image is largely affected by the body position with variable magnification rates and distortion rates for different parts [19, 20]. Previously, panoramic radiography is shown to be a sufficiently accurate method to obtain the interatral bone height in the incisor area, but not in the canine area as compared with CBCT [21].

It is meaningful to determine the magnification rate of OPG for clinical guidance. The present study showed that the vertical OPG magnification rates of the first mo- lars in the right and left upper jaws were 10.83% and 13.02% respectively; the magnification rates of the man- dibular first molars were 7.09% and 5.96% respectively.

The correlation coefficients (R) between the paired sam- ples obtained from OPG and CBCT in the vertical and horizontal direction were highly related (P < 0.05).

Fig. 2 CBCT images showing the vertical measurement on X a, Y b and Z c planes and horizontal measurement d-f

Table 1 Correlation coefficients between the paired samples obtained from OPG and CBCT at different teeth

Teeth 11 21 16 26 36 46

CC in vertical distance 0.858* 0.930* 0.959* 0.933* 0.880* 0.840*

CC in horizontal distance 0.777* 0.707* 0.703* 0.783* 0.904* 0.828*

* indicates a significant correlation (P < 0.05)

CC correlation coefficient, OPG orthopantomography, CBCT cone beam computerized tomography

(5)

Therefore, the magnification rates could possibly provide some guidance for implanting when determining the safety distance based on OPG images [22, 23].

Distortion of panoramic radiographs may be resulted from the distance between the X-ray source, and film or imaging plate, the difference between the axis motion track of scan and the shapes of inspected parts, and the velocity of film (or imaging plate) relative to the X-ray beam[20, 24, 25]. The distortion rate may differ due to in- struments, shooting positions and measurement methods, and is therefore very different, typically ranging from below 30% to over 50% [26, 27]. Besides, the form and symmetry of the dental arch, teeth arrangement, teeth shape, the tilt angle of teeth and the surrounding tissues

also exert an influence on the image. Tong et al. found that the vertical OPG magnification rate is about 25%, which is the same as the magnification rates of the ma- chine [28]. He also showed that the magnification rate is similar among the patients, with few exceptions. These re- sults are consistent with ours.

The mean vertical magnification rates were 5.55% and 4.84% for the central incisors in the upper right and left jaws respectively, suggesting that OPG is relatively accur- ate for measurement of vertical bone volume. The mean vertical magnification rates were 6.53% and 7.47% for the central incisors in the upper right and left jaws respect- ively; the difference is influenced by the shape of alveolar bone, rotation angle and tilt angle of the teeth. The factors

Fig. 3 The scatter plot showing the correlations between the two sets of the vertical measurements. The correlations in in the teeth of 11 a, 21 b, 16 c, 26 d, 36 e and 46 f

(6)

affecting the measurement of the front tooth are mainly the inclination angle of the alveolar bone, nasal shape and position. The major factors limiting the planting of front tooth are the faciolingual thickness of bone plate and OPG as two-dimensional imaging is not able to provide information regarding the thickness. Therefore, we didn’t perform any comparison concerning the thickness be- tween the two scanning methods, which is a limitation of our study. During the clinical practice, CBCT has to be used when the alveolar bone density and thickness in the implanting area couldn’t be determined by OPG. There are other limitations. For example, the medial lateral nerve location and the avoidance of structures had better to be taken into consideration. The comparison at more loci should be further performed.

Conclusion

During our clinical practice, we found that there was huge difference in alveolar bone volumes obtained from OPG and CBCT in the patients with periodon- tal diseases. Lin et al. reported that the alveolar bone density decreased in the patients with peri- odontitis, which was in consistent with the changes of their alveolar bone.[29] Therefore, these patients were excluded from the study. To lower the risks, patients with moderate or severe periodontal dis- eases are not suggested to implant based on OPG alone. In conclusion, the magnification rates of OPG at these teeth are different. The distances measured by OPG were highly correlated with that measured by CBCT.

Fig. 4 The scatter plot showing the correlations between the two sets of the horizontal measurements. The correlations in the teeth of 11 a, 21 b, 16 c, 26 d, 36 e and 46 f

(7)

Abbreviations

CBCT:Cone beam computerized tomography; ICC: Interclass correlation co- efficiency; OPG: Orthopantomography

Acknowledgements Not applicable.

Funding

This research is funded by National Natural Science Funds of China (Grants number: 81300841).

Availability of data and materials

The dataset(s) supporting the conclusions of this article is(are) included within the article.

Authors’ contributions

ZT and KC carried out the studies and drafted the manuscript. XC made the literature search and performed the statistical analysis. KC conceived of the study and make the critical revision. All authors read and approved the final manuscript.

Competing interest

The authors declare that they have no competing interests.

Consent for publication

Written informed consent was obtained from the patient’s legal guardian(s) for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.

Ethics approval and consent to participate

The ethical approval (reference number: 20150902) for this study was obtained from the Medical Ethics Committee of Xiangya Stomatological Hospital of Central South University, China.

Written informed consent was obtained from all the patients and in the case of minor from the patient’s legal guardian(s).

Received: 23 August 2016 Accepted: 15 February 2017

References

1. Choi JW. Assessment of panoramic radiography as a national oral examination tool: review of the literature. Imaging Sci Dent. 2011;41(1):1–6.

2. White SC, Weissman DD. Relative discernment of lesions by intraoral and panoramic radiography. J Am Dent Assoc. 1977;95(6):1117–21.

3. Douglass CW, Valachovic RW, Wijesinha A, Chauncey HH, Kapur KK, McNeil BJ. Clinical efficacy of dental radiography in the detection of dental caries and periodontal diseases. Oral Surg Oral Med Oral Pathol. 1986;62(3):330–9.

4. Meister Jr F, Simpson J, Davies EE. Oral health of airmen: analysis of panoramic radiographic and Polaroid photographic survey. J Am Dent Assoc. 1977;94(2):335–9.

5. Morris CR, Marano PD, Swimley DC, Runco JG. Abnormalities noted on panoramic radiographs. Oral Surg Oral Med Oral Pathol. 1969;28(5):772–82.

6. Ahlqwist M, Halling A, Hollender L. Rotational panoramic radiography in epidemiological studies of dental health. Comparison between panoramic radiographs and intraoral full mouth surveys. Swed Dent J. 1986;10(1-2):73–84.

7. Yang L, Li F, Cao M, Chen H, Wang X, Chen X, Yang L, Gao W, Petrone JF, Ding Y. Quantitative evaluation of maxillary interradicular bone with cone- beam computed tomography for bicortical placement of orthodontic mini- implants. Am J Orthod Dentofacial Orthop. 2015;147(6):725–37.

8. Sheikhi M, Dakhil-Alian M, Bahreinian Z. Accuracy and reliability of linear measurements using tangential projection and cone beam computed tomography. Dent Res J (Isfahan). 2015;12(3):271–7.

9. Dalessandri D, Laffranchi L, Tonni I, Zotti F, Piancino MG, Paganelli C, Bracco P. Advantages of cone beam computed tomography (CBCT) in the orthodontic treatment planning of cleidocranial dysplasia patients: a case report. Head Face Med. 2011;7:6.

10. Fornell J, Johansson LA, Bolin A, Isaksson S, Sennerby L. Flapless, CBCT- guided osteotome sinus floor elevation with simultaneous implant installation. I: radiographic examination and surgical technique. A prospective 1-year follow-up. Clin Oral Implants Res. 2012;23(1):28–34.

11. van der Zel JM. Implant planning and placement using optical scanning and cone beam CT technology. J Prosthodont. 2008;17(6):476–81.

12. Dove SB, McDavid WD, Welander U, Tronje G. Preliminary evaluation of a digital system for rotational panoramic radiography. Oral Surg Oral Med Oral Pathol. 1992;73(5):623–32.

13. Hauret L, Hodez C. A new modality for dentomaxillofacial imaging: cone beam CT. J Radiol. 2009;90(5 Pt 2):604–17.

14. Loubele M, Van Assche N, Carpentier K, Maes F, Jacobs R, van Steenberghe D, Suetens P. Comparative localized linear accuracy of small-field cone- beam CT and multislice CT for alveolar bone measurements. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008;105(4):512–8.

15. Suomalainen A, Pakbaznejad Esmaeili E, Robinson S. Dentomaxillofacial imaging with panoramic views and cone beam CT. Insights Imaging. 2015;

6(1):1–16.

16. Arai Y, Tammisalo E, Iwai K, Hashimoto K, Shinoda K. Development of a compact computed tomographic apparatus for dental use. Dentomaxillofac Radiol. 1999;28(4):245–8.

17. Mozzo P, Procacci C, Tacconi A, Martini PT, Andreis IA. A new volumetric CT machine for dental imaging based on the cone-beam technique:

preliminary results. Eur Radiol. 1998;8(9):1558–64.

18. Rushton VE, Horner K, Worthington HV. Aspects of panoramic radiography in general dental practice. Br Dent J. 1999;186(7):342–4.

19. Alqerban A, Jacobs R, Fieuws S, Willems G. Comparison of two cone beam computed tomographic systems versus panoramic imaging for localization of impacted maxillary canines and detection of root resorption. Eur J Orthod. 2011;33(1):93–102.

20. Miller CS, Nummikoski PV, Barnett DA, Langlais RP. Cross-sectional tomography. A diagnostic technique for determining the buccolingual relationship of impacted mandibular third molars and the inferior alveolar neurovascular bundle. Oral Surg Oral Med Oral Pathol. 1990;70(6):791–7.

21. Kopecka D, Simunek A, Streblov J, Slezak R, Capek L. Measurement of the interantral bone in implant dentistry using panoramic radiography and cone beam computed tomography: A human radiographic study. West Indian Med J. 2014;63(5):503–9.

22. Han F, Wang T, Liao B, Han C, Qin J. Study on magnification of the marking position with digital pantomography. J Oral Sci Res (Chinese journal). 2012;

28(2):121–24.

23. Wang J, Lu X, Wang Y, Wang H. A quantified study on distortion rate of implant bed in computed orthopantomography. Guangdong Odontopathy Prev. 2007;15(7):294–95.

24. Thonissen P, Ermer MA, Schmelzeisen R, Gutwald R, Metzger MC, Bittermann G. Sensitivity and specificity of cone beam computed tomography in thin bony structures in maxillofacial surgery - A clinical trial.

J Craniomaxillofac Surg. 2015;43(7):1284-8.

25. Vazquez L, Nizamaldin Y, Combescure C, Nedir R, Bischof M, Dohan Ehrenfest DM, Carrel JP, Belser UC. Accuracy of vertical height measurements on direct digital panoramic radiographs using posterior mandibular implants and metal balls as reference objects. Dentomaxillofac Radiol. 2013;42(2):20110429.

26. Arora H, Jain V, Pai KM, Kamboj R. Precision of dimensional measurements of mandible in different positions on orthopantomogram. Indian J Dent Res. 2013;24(1):48–51.

27. Catic A, Celebic A, Valentic-Peruzovic M, Catovic A, Jerolimov V, Muretic I.

Evaluation of the precision of dimensional measurements of the mandible on panoramic radiographs. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1998;86(2):242–8.

28. Tong L, Chen D. Clinical analysis of vertical amplicatio ratio in jaw panoramic radiograph. Chinese journal of new clinic medicine. 2009;2(11):1152–4.

29. Lin Z, Wang T, Lin H, Ge J, Wu W. Evaluation of mandibule bone loss of periodontitis with standard digital panoramic tomogram. West China J Stomatol. 2008;26(1):60–3. 66.

參考文獻

相關文件

Milk and cream, in powder, granule or other solid form, of a fat content, by weight, exceeding 1.5%, not containing added sugar or other sweetening matter.

Later, though, people learned that Copernicus was in fact telling the

Estimated resident population by age and sex in statistical local areas, New South Wales, June 1990 (No. Canberra, Australian Capital

[This function is named after the electrical engineer Oliver Heaviside (1850–1925) and can be used to describe an electric current that is switched on at time t = 0.] Its graph

You are given the wavelength and total energy of a light pulse and asked to find the number of photons it

Wang, Solving pseudomonotone variational inequalities and pseudocon- vex optimization problems using the projection neural network, IEEE Transactions on Neural Networks 17

volume suppressed mass: (TeV) 2 /M P ∼ 10 −4 eV → mm range can be experimentally tested for any number of extra dimensions - Light U(1) gauge bosons: no derivative couplings. =&gt;

Define instead the imaginary.. potential, magnetic field, lattice…) Dirac-BdG Hamiltonian:. with small, and matrix