• 沒有找到結果。

According to AASM published classification of types of portable PSG, all type of PSG require pulse oximetry to regard as parameter for sleep examination. In our new proposed PSG system we integrate this parameter into system by software. PSG Client receives two kinds of signals from original bio-signal acquisition unit and pulse oximeter simultaneously. Unfortunately two kinds of signals can’t synchronize completely. At next version of PSG device, in order to ensure the synchronization we require to integrate pulse oximetry into system by hardware.

The secure network connection in our proposed system adopts RSA algorithm.

There exists a key-pair (public key and private key) on PSG Client and PSG Server.

At initial state of PSG Client connect to PSG Server, we have to exchange each other’s public key by direct connection. But this way of exchange key exists some risk, because that the exchanged keys could be intercepted and modified. We have to exchange each other’s public key in safer way like off-line transmission by human, but it is not efficient usually. Or we have to establish third-party certification authority.

It can certify the identity of connection between two sides.

In PSG Server, we can add the function of automatic sleep stage classification.

This function can assist sleep physician to do sleep diagnosis more efficiently.

References

[1] T. Young, et al., "The occurrence of sleep-disordered breathing among mddle-aged adults," New England Journal of Medicine, vol. 328, pp.

1230-1235, Apr 1993.

[2] P. E. Peppard, et al., "Prospective study of the association between sleep-disordered breathing and hypertension," New England Journal of Medicine, vol. 342, pp. 1378-1384, May 2000.

[3] E. Shahar, et al., "Sleep-disordered breathing and cardiovascular disease:

Cross-sectional results of the sleep heart health study," American Journal of Respiratory and Critical Care Medicine, vol. 163, pp. 19-25, Jan 2001.

[4] H. K. Yaggi, et al., "Obstructive sleep apnea as a risk factor for stroke and death," New England Journal of Medicine, vol. 353, pp. 2034-2041, Dec 2005.

[5] A. R. Babu, et al., "Type 2 diabetes, glycemic control, and continuous positive airway pressure in obstructive sleep apnea," Archives of Internal Medicine, vol. 165, pp. 447-452, Feb 2005.

[6] A. Gruber, et al., "Obstructive sleep apnoea is independently associated with the metabolic syndrome but not insulin resistance state," CARDIOVASC DIABETOL, vol. 5, p. 22, 2006.

[7] M. E. Howard, et al., "Sleepiness, sleep-disordered breathing, and accident risk factors in commercial vehicle drivers," American Journal of Respiratory and Critical Care Medicine, vol. 170, pp. 1014-1021, Nov 2004.

[8] T. Akashiba, et al., "Relationship between quality of life and mood or

depression in patients with severe obstructive sleep apnea syndrome," Chest, vol. 122, pp. 861-865, Sep 2002.

[9] P. Gay, et al., "Evaluation of positive airway pressure treatment for sleep related breathing disorders in adults," Sleep, vol. 29, pp. 381-401, Mar 2006.

[10] R. Ferber, et al., "Portable recording in the assessment of obstructive sleep-apnea," Sleep, vol. 17, pp. 378-392, Jun 1994.

[11] "The AASM Manual for the scoring of sleep and associated events. Rules terminology and technical specifications," 2007.

[12] C. Iber, et al., "Polysomnography performed in the unattended home versus

the attended laboratory setting - Sleep heart health study methodology," Sleep, vol. 27, pp. 536-540, 2004.

[13] S. D. Pittman, et al., "Using a wrist-worn device based on peripheral arterial tonometry to diagnose obstructive sleep apnea: In-laboratory and ambulatory validation," Sleep, vol. 27, pp. 923-933, 2004.

[14] P. C. Gay and P. A. Selecky, "Are Sleep Studies Appropriately Done in the Home?," Respiratory Care, vol. 55, pp. 66-73, 2010.

[15] B. Kemp, et al., "A simple format for exchange of digitized polygraphic recordings," Electroencephalography and Clinical Neurophysiology, vol. 82, pp. 391-393, 1992.

[16] B. R. Cahn and J. Polich, "Meditation states and traits: EEG, ERP, and neuroimaging studies," Psychological Bulletin, vol. 132, pp. 180-211, Mar 2006.

[17] J. Malmivuo and R. Plonsey, Bioelectromagnetism New York Oxford, 1995.

[18] T. S. Johnson, Sleep Apnea-The Phantom of the Night, 3 Edition ed.: New Technology Publishing, 2003.

[19] Interacoustics, "Rhinometry," ed, 2010.

[20] W. R. Stevens., et al., UNIX Network Programming Volume 1, Third Edition:

The Sockets Networking API: Wesley, 2003.

[21] R. Richardson, "2008 CSI Computer Crime and Security Survey," 2008.

[22] S. K. Miller. (2006, Nov 15) Fiber Optic Networks Vulnerable to Attack.

Information Security Magazine.

[23] H. E. Michail, et al., "Optimizing SHA-1 hash function for high throughput with a partial unrolling study," in Integrated Circuit and System Design - Power and Timing Modeling, Optimization and Simulation. vol. 3728, V.

Paliouras, et al., Eds., ed Berlin: Springer-Verlag Berlin, 2005, pp. 591-600.

[24] R. C. Merkle, "A fast software one-way hash function," Journal of Cryptology, vol. 3, pp. 43-58, 1990 1990.

[25] J. Daemen. and V. Rijmen., The Design of Rijndael: AES - The Advanced Encryption Standard: Springer, 2002.

[26] J. Schwartz. (2000, Oct 3). U.S. Selects a New Encryption Technique.

[27] Wikimedia Foundation Inc. Advanced Encryption Standard. Available:

http://en.wikipedia.org/wiki/Advanced_Encryption_Standard

[28] G. Bertoni, et al., Efficient software implementation of AES on 32-bit platforms vol. 2523: Springer Berlin / Heidelberg, 2003.

[29] R.L. Rivest, et al. (1978), A Method for Obtaining Digital Signatures and Public-Key Cryptosystems.

[30] R. Barreira, "Cryptanalysis of SHA-1," in Schneier on Security, ed, 2005.

[31] Wikimedia Foundation Inc. SHA-1. Available:

http://en.wikipedia.org/wiki/Sha-1

[32] The Security Division of EMC. What is a digital envelope? Available:

http://www.rsa.com/rsalabs/node.asp?id=2184

[33] Microsoft Corporation. Introduction to the C# Language and the .NET Framework. Available:

http://msdn.microsoft.com/library/z1zx9t92(VS.100).aspx

[34] C. H. Chung, "The Development of Wireless Polysomnography System for Sleep Monitoring At Home," Master Thesis of Computer Science and Engineering, National Chiao Tung University, 2009.

[35] Wikimedia Foundation Inc. Correlation and dependence. Available:

http://en.wikipedia.org/wiki/Correlation

[36] Kellerman Software. (2008, Jul). What is the strongest encryption algorithm?

Available: http://www.kellermansoftware.com/t-ArticleStrongestAlgo.aspx

相關文件