• 沒有找到結果。

Finger and Palm Dynamic Pressure Monitoring for Basketball Shooting

N/A
N/A
Protected

Academic year: 2021

Share "Finger and Palm Dynamic Pressure Monitoring for Basketball Shooting"

Copied!
6
0
0

加載中.... (立即查看全文)

全文

(1)

Research Article

Finger and Palm Dynamic Pressure Monitoring for

Basketball Shooting

Chiao-Fang Hung,

1

Chung-Chiang Chen,

2

Shin-Hung Lin,

1

and Tien-Kan Chung

1,3

1Department of Mechanical Engineering, National Chiao Tung University, Hsinchu 30010, Taiwan

2Office of Physical Education, National Chiao Tung University, Hsinchu 30010, Taiwan

3International College of Semiconductor Technology, National Chiao Tung University, Hsinchu 30010, Taiwan

Correspondence should be addressed to Tien-Kan Chung; tkchung@nctu.edu.tw Received 3 February 2017; Accepted 4 May 2017; Published 23 May 2017 Academic Editor: Andrea Cusano

Copyright © 2017 Chiao-Fang Hung et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

This study verified general inferences on the finger and palm pressure distribution of a basketball player in the moment before that player shoots a basketball through a scientific qualitative testing method. We mounted the sensor on the hands of college basketball players and monitored the dynamic pressure of each player’s hand while the player threw a basketball. The dynamic pressure distribution of the fingers and palm of a basketball player throwing a ball can be verified. According to the experimental results, college basketball players typically use the index finger to control the direction and power of force in the moment before shooting a basketball. This study successfully used a scientific qualitative test method to monitor the dynamic pressure of the fingers and palms of basketball players and verified the general inference that a typical basketball player mainly uses the index finger to control the direction and power of force in the moment before throwing a ball. In the future, this study, measuring the dynamic pressure distribution of the fingers and palm, can be applied to simulate hand manipulation in many biomedical and robotic applications.

1. Introduction

A variety of pressure sensors are currently used in the industry, mainly piezoresistive, capacitive, and piezoelectric sensors. Among these, piezoresistive pressure sensors [1–5] have scope for use in practical applications for sensing the human body [6–12], such as all kinds of haptic sensing of the human body [13–17] including haptic sensing of fingers and palms [18–20].

Recently, a general inference on the finger and palm pres-sure distribution of a basketball player in the moment before shooting a basketball has been derived: a typical basketball player uses the index finger to control the direction and power of force in the moment before throwing a basketball. To support this general inference, some researchers claimed that, according to the principles of human-motion mechanics, the basketball player uses the index finger to control the direction and the power of the shooting force in the moment

right before shooting a basketball [21]. This is because the index finger is the longest finger and the working distance is the longest distance, and both are helpful to control the direction and the power of the force for shooting the bas-ketball. However, currently, no related experimental dynamic pressure sensing/monitoring research has been completely conducted on a basketball player using the index finger in the moment before throwing a basketball. In other words, the aforementioned general inference has not been scientifically verified. To qualitatively measure and scientifically verify this general inference, we used the TekScan Grip system [22] as a pressure sensor to monitor the dynamic pressure of the fingers and palms of basketball players while they were throwing balls. By analyzing each player’s result from the dynamic pressure monitoring of the fingers and palm, we verified the aforementioned general inference by using a scientific qualitative test method. Furthermore, our verified approach measuring the dynamic pressure distribution of

Volume 2017, Article ID 9352410, 5 pages https://doi.org/10.1155/2017/9352410

(2)

Sensor tab VersaTek cuff Cuff cable Monitoring computer USB cable AC power VersaTek hub (a) i1 i2 i3 m1 m2 m3 r2 r1 r3 l1 l2 l3 t1 t2 p1 p2 p3 (b)

Figure 1: (a) Illustration of TekScan Grip system configuration. (b) Illustration of the finger and palm pressure distribution.

the fingers and palm can be applied in many biomedical and robotic applications for simulating hand manipulation. For example, our approach can be modified to design an anthropomorphic robot hand and measure the pressure dis-tributions of the robot hand [23], to achieve haptic feedback (tactile and force) [24, 25] in robotic surgery using the da Vinci robotic system [26], and to measure the hand-arm biodynamic response for real power tool handles [27]. Due to these, our approach not only can be used for current sport-science applications, but also can provide an important design reference for developing future hand-manipulation stimulating technologies in medical and robotic applications. The design, testing, results, and discussion of our approach are described in the following sections.

2. Design

The TekScan Grip system is illustrated in Figure 1(a). The main devices constituting this system are the sensor tab, VersaTek cuff, VersaTek hub, and a monitoring computer. The area of the sensor tab comprises 18 independent pressure sensing areas, which can monitor the pressure of the fingers and palm. The connection configuration of the TekScan Grip system is as follows. First, the sensor tab is connected to the VersaTek cuff. The VersaTek cuff can transfer the signals from the sensor tab to the cuff cable. Subsequently, the cuff cable is connected to the VersaTek hub. Finally, the AC power of the VersaTek hub is connected to the TekScan Grip system, and the VersaTek hub is connected to the monitoring computer with a USB cable to monitor the pressure distribution of the fingers and palm. The finger and palm pressure distribution is shown in Figure 1(b); the figure shows the pressure distribution of each area of the palm (𝑝1, 𝑝2, and𝑝3) and each segment of the thumb (𝑡1and𝑡2), index finger (𝑖1,𝑖2, and𝑖3), middle finger (𝑚1, 𝑚2, and𝑚3), ring finger (𝑟1,𝑟2, and𝑟3), and little finger (𝑙1,𝑙2, and𝑙3). By using the TekScan Grip system, we can monitor and record the

pressure of the fingers and palm of a basketball player while that player is throwing a ball and determine the pressure of each area of the palm and each segment of each finger.

3. Testing

To measure the actual behavior of basketball players, we asked the college basketball players to wear the sensor system and perform ball-shooting, and we monitored and recorded the pressure levels of their right hands. To facilitate the sensor installation on the hands of the basketball play-ers, adjust the sensor positions, and avoid hygienic issues, we mounted the sensor tab on their gloves (latex gloves, thickness 0.15 mm; Taihang Enterprise Co. Ltd., Hsinchu, Taiwan), following the procedure of Mastalerz et al. [6]. Furthermore, to prevent the VersaTek cuff from affecting the operation of the basketball player while shooting the ball, we carefully affixed the VersaTek cuff to the upper arm of each player. After completing these configurations of the TekScan Grip system, we investigated the finger and palm pressure distributions of the players by analyzing the recording of the sensor system. In addition, the players who we chose for test have common features: college student, about 20 years old, having a little nonprofessional basketball training (e.g., school team member or department team member), and about 175–180 cm height with a similar stature. Due to the choosing criteria, the test results are comparable.

4. Results and Discussion

The records of the finger and palm dynamic pressure dis-tributions of college basketball players, that is, the school basketball team member and the department basketball team member, are shown in Figures 2 and 3, respectively. We can analyze the results of the dynamic pressure monitoring of the fingers and palm in three stages (first, holding the ball; second, lifting the ball overhead; and third, the moment

(3)

(a) (b) (c) (d)

(e) (f)

Figure 2: Photographs while shooting a ball and the finger and palm pressure distribution of the school basketball team member at the following stages: (a, b) holding the ball, (c, d) lifting the ball overhead, and (e, f) the moment before shooting the ball.

before shooting the ball). By comparing these distributions of dynamic pressure of the finger and palm, we obtained the following results. While holding the ball, most of the fingers of both basketball players had a high-pressure distribution, as shown in Figures 2(a), 2(b), 3(a), and 3(b). Because each player’s habits are different, the pressure distributions were also different. While lifting the ball overhead, the finger and palm pressure distribution of both basketball players was observed on all fingers, as shown in Figures 2(c), 2(d), 3(c), and 3(d). Finally, in the moment before shooting the ball, both basketball players mainly used the index finger to control the direction and power for shooting the ball, as shown in Figures 2(e), 2(f), 3(e), and 3(f). These results are consistent with the aforementioned general inference. Thus, we successfully verified the general inference on the finger and palm pressure distribution by using the scientific qualitative test method.

5. Conclusions

By using the piezoresistive pressure sensing/monitoring sys-tem, we successfully verified the general inference on the finger and palm dynamic pressure distribution in the moment while the basketball players throw the ball (i.e., during

ball-shooting). The experimental results of the dynamic pressure monitoring revealed that the college basketball play-ers mainly used the index finger to control the direction and power for shooting the ball. These results not only verified the general inference but also could provide a reference for current basketball sport science. Moreover, our approach can provide an important design reference for future hand-manipulation simulating technologies in medical and robotic applications.

Conflicts of Interest

The authors declare that there are no conflicts of interest regarding the publication of this paper.

Authors’ Contributions

Chiao-Fang Hung and Chung-Chiang Chen contributed equally to this work.

Acknowledgments

This work is supported by the Ministry of Science and Technology, Taiwan (Grant no. 105-2628-E-009-001-MY2).

(4)

(a) (b) (c) (d)

(e) (f)

Figure 3: Photographs while shooting a ball and the finger and palm pressure distribution of the department basketball team member at the following stages: (a, b) holding the ball, (c, d) lifting the ball overhead, and (e, f) the moment before shooting the ball.

References

[1] J. Zavickis, M. Knite, K. Ozols, and G. Malefan, “Develop-ment of percolative electroconductive structure in piezore-sistive polyisoprene-nanostructured carbon composite during vulcanization,” Materials Science & Engineering C-Materials for

Biological Applications, vol. 31, no. 2, pp. 472–476, 2011.

[2] H.-B. Yao, J. Ge, C.-F. Wang et al., “A flexible and highly pres-sure-sensitive graphene-polyurethane sponge based on frac-tured microstructure design,” Advanced Materials, vol. 25, no. 46, pp. 6692–6698, 2013.

[3] E. Laukhina, R. Pfattner, L. R. Ferreras et al., “Ultrasensitive piezoresistive all-organic flexible thin films,” Advanced

Materi-als, vol. 22, no. 9, pp. 977–981, 2010.

[4] S. Stassi, V. Cauda, G. Canavese, and C. F. Pirri, “Flexible tactile sensing based on piezoresistive composites: a review,” Sensors, vol. 14, no. 3, pp. 5296–5332, 2014.

[5] J. Sosa, J. A. Montiel-Nelson, R. Pulido, and J. C. Garcia-Montesdeoca, “Design and Optimization of a Low Power Pressure Sensor for Wireless Biomedical Applications,” Journal

of Sensors, vol. 2015, Article ID 352036, 2015.

[6] A. Mastalerz, E. Nowak, I. Palczewska, and E. Kalka, “Maximal grip force during holding a cylindrical handle with different diameters,” Human Movement, vol. 10, no. 1, pp. 26–30, 2009. [7] S. Chun, H. Jung, Y. Choi, G. Bae, J. P. Kil, and W. Park, “A tactile

sensor using a graphene film formed by the reduced graphene

oxide flakes and its detection of surface morphology,” Carbon, vol. 94, pp. 982–987, 2015.

[8] A. J. Shaw, B. A. Davis, M. J. Collins, and L. G. Carney, “A Tech-nique to Measure Eyelid Pressure Using Piezoresistive Sensors,”

IEEE Transactions on Biomedical Engineering, vol. 56, no. 10, pp.

2512–2517, 2009.

[9] J. C. Roberts, A. C. Merkle, P. J. Biermann et al., “Computa-tional and experimental models of the human torso for non-penetrating ballistic impact,” Journal of Biomechanics, vol. 40, no. 1, pp. 125–136, 2007.

[10] Y. Wang, L. Wang, T. Yang et al., “Wearable and highly sen-sitive graphene strain sensors for human motion monitoring,”

Advanced Functional Materials, vol. 24, no. 29, pp. 4666–4670,

2014.

[11] M. Melnykowycz, M. Tschudin, and F. Clemens, “Piezoresistive soft condensed matter sensor for body-mounted vital function applications,” Sensors (Switzerland), vol. 16, no. 3, article no. 326, 2016.

[12] D. Giovanelli and E. Farella, “Force sensing resistor and evalua-tion of technology for wearable body pressure sensing,” Journal

of Sensors, vol. 2016, Article ID 9391850, 2016.

[13] A. Drimus, G. Kootstra, A. Bilberg, and D. Kragic, “Design of a flexible tactile sensor for classification of rigid and deformable objects,” Robotics and Autonomous Systems, vol. 62, no. 1, pp. 3– 15, 2014.

[14] R. E. Fan, M. O. Culjat, C.-H. King et al., “A haptic feedback system for lower-limb prostheses,” IEEE Transactions on Neural

(5)

Systems and Rehabilitation Engineering, vol. 16, no. 3, pp. 270–

277, 2008.

[15] M. Y. Chuah and S. Kim, “Enabling force sensing during ground locomotion: A bio-inspired, multi-axis, composite force sensor using discrete pressure mapping,” IEEE Sensors Journal, vol. 14, no. 5, pp. 1693–1703, 2014.

[16] J. Castellanos-Ramos, R. Navas-Gonz´alez, H. Macicior, T. Sikora, E. Ochoteco, and F. Vidal-Verd´u, “Tactile sensors based on conductive polymers,” Microsystem Technologies, vol. 16, no. 5, pp. 765–776, 2010.

[17] C.-H. King, M. O. Culjat, M. L. Franco et al., “Tactile feedback induces reduced grasping force in robot-assisted surgery,” IEEE

Transactions on Haptics, vol. 2, no. 2, pp. 103–110, 2009.

[18] J. Hwang, J. Jang, K. Hong et al., “Poly(3-hexylthiophene) wrapped carbon nanotube/poly(dimethylsiloxane) composites for use in finger-sensing piezoresistive pressure sensors,”

Car-bon, vol. 49, no. 1, pp. 106–110, 2011.

[19] C. Antfolk, C. Balkenius, G. Lundborg, B. Rosen, and F. Sebelius, “A tactile display system for hand prostheses to dis-criminate pressure and individual finger localization,” Journal of

Medical and Biological Engineering, vol. 30, no. 6, pp. 355–359,

2010.

[20] A. M. Almassri, W. Z. W. Hasan, and S. A. Ahmad, “Pressure sensor: state of the art, design, and application for robotic hand,”

Journal of Sensors, vol. 2015, Article ID 846487, 12 pages, 2015.

[21] L. Zhen, L. Wang, and Z. Hao, “A biomechanical analysis of bas-ketball shooting,” International Journal of Simulation—Systems,

Science & Technology, vol. 16, no. 3B, p. 1, 2015.

[22] TekScan Grip System. Available online: https://www.tekscan .com/products-solutions/systems/grip-system.

[23] H. Kawasaki, T. Komatsu, and K. Uchiyama, “Dexterous anthro-pomorphic robot hand with distributed tactile sensor: Gifu hand II,” IEEE/ASME Transactions on Mechatronics, vol. 7, no. 3, pp. 296–303, 2002.

[24] C. Diaz and S. Payandeh, “Multimodal Sensing Interface for Haptic Interaction,” Journal of Sensors, vol. 2017, Article ID 2072951, 24 pages, 2017.

[25] C. Wu, A. Song, Y. Ling, N. Wang, and L. Tian, “A control strategy with tactile perception feedback for emg prosthetic hand,” Journal of Sensors, vol. 2015, Article ID 869175, 15 pages, 2015.

[26] M. Culjat, C.-H. King, M. Franco, J. Bisley, W. Grundfest, and E. Dutson, “Pneumatic balloon actuators for tactile feedback in robotic surgery,” Industrial Robot, vol. 35, no. 5, pp. 449–455, 2008.

[27] M. Kalra, S. Rakheja, P. Marcotte, K. N. Dewangan, and S. Adewusi, “Feasibility analysis of low-cost flexible resistive sen-sors for measurements of driving point mechanical impedance of the hand-arm system,” International Journal of Industrial

(6)

,QWHUQDWLRQDO-RXUQDORI

$HURVSDFH

(QJLQHHULQJ

+LQGDZL3XEOLVKLQJ&RUSRUDWLRQ KWWSZZZKLQGDZLFRP 9ROXPH

Robotics

Journal of

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014 Active and Passive Electronic Components

Control Science and Engineering

Journal of

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Machinery

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014 Hindawi Publishing Corporation

http://www.hindawi.com

Journal of

(QJLQHHULQJ

Volume 201

Submit your manuscripts at

https://www.hindawi.com

VLSI Design

Hindawi Publishing Corporation

http://www.hindawi.com Volume

201-Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014 Shock and Vibration Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Civil Engineering

Advances in

Acoustics and VibrationAdvances in Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Electrical and Computer Engineering

Journal of

Advances in OptoElectronics

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

The Scientific

World Journal

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Sensors

Journal of

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Modelling & Simulation in Engineering

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Chemical Engineering

International Journal of Antennas and

Propagation International Journal of

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Navigation and Observation International Journal of

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Distributed

Sensor Networks

數據

Figure 1: (a) Illustration of TekScan Grip system configuration. (b) Illustration of the finger and palm pressure distribution.
Figure 2: Photographs while shooting a ball and the finger and palm pressure distribution of the school basketball team member at the following stages: (a, b) holding the ball, (c, d) lifting the ball overhead, and (e, f) the moment before shooting the bal
Figure 3: Photographs while shooting a ball and the finger and palm pressure distribution of the department basketball team member at the following stages: (a, b) holding the ball, (c, d) lifting the ball overhead, and (e, f) the moment before shooting the

參考文獻

相關文件

The hashCode method for a given class can be used to test for object equality and object inequality for that class. The hashCode method is used by the java.util.SortedSet

substance) is matter that has distinct properties and a composition that does not vary from sample

 Promote project learning, mathematical modeling, and problem-based learning to strengthen the ability to integrate and apply knowledge and skills, and make. calculated

- Informants: Principal, Vice-principals, curriculum leaders, English teachers, content subject teachers, students, parents.. - 12 cases could be categorised into 3 types, based

Wang, Solving pseudomonotone variational inequalities and pseudocon- vex optimization problems using the projection neural network, IEEE Transactions on Neural Networks 17

Define instead the imaginary.. potential, magnetic field, lattice…) Dirac-BdG Hamiltonian:. with small, and matrix

z gases made of light molecules diffuse through pores in membranes faster than heavy molecules. Differences

Microphone and 600 ohm line conduits shall be mechanically and electrically connected to receptacle boxes and electrically grounded to the audio system ground point.. Lines in