Experimental Investigation of Effect of Corrugation Angle on Local Heat Transfer Characteristics of a Corrugated Plate
張志全、吳佩學
E-mail: [email protected]
ABSTRACT
Heat exchanger can be used and applied to a very extensive range. The most typical and common applications of the heat transfer enhancement are on the plate heat exchange. So far, most of the plate heat exchanger research and analysis are focused on the total pressure drop and the heat transfer coefficient. According to this method, you can only adapt the benchmarks of the total pressure drop or heat transfer coefficient. Meanwhile, the numerical calculation data is significantly different from the actual experimental results. Furthermore, the measurement of the full –wall convective heat transfer coefficient is still less reference for public
documents.Therefore, the following experiments are aimed at different angles (30°,45°,60° ) wave plate flow channel in full wall heat transfer coefficient distribution of the measured data to come out the results.At the same time, they are adapted the different corrugation angles’ and the different Reynolds numbers’ circumstances to evaluate the conditions of the channel full wall convection heat transfer coefficients and pressure drop. The results show that the average Nusselt number of the entrance are vulnerable to the influence of plate geometry of the poor reliability of it value on the plate. And the differences of the two plates’
average Nusselt values’ high and low are changed by the corrugation angle of the grain direction and direction of flowing of the folder. In the other words, when the substances are accumulated to flow from the exit of the up board, Nusselt value is up. But when the substances didn’t flow from the exit of the down board, Nusselt value is down.
Keywords : plate heat exchangers、corrugated angle、transient liquid crystal technology、local heat transfer coefficient Table of Contents
封面內頁 簽名頁 中文摘要 ... iii ABSTRACT ... iv 致謝
... vi 目錄 ... vii 圖目錄 ... x 表目錄
... xvi 符號說明 ... xvii 第一章 緒論 ... 1 1.1研究背景 ... 1 1.2 研究目的 ... 3 1.3 文獻回顧 ... 4 第二章 實驗系統與 研究方法 ... 12 2.1實驗系統 ... 12 2.1.1褶紋角波型板片設計 ... 12 2.1.2高壓 熱風機 ... 15 2.1.3流量計 ... 16 2.1.4快速切換閥 ... 16 2.1.5穩壓艙 ... 16 2.1.6差壓指示計 ... 17 2.2實驗儀器校正 ... 17 2.2.1 熱偶校正 ... 17 2.2.2影像處理系統及程序 ... 19 2.2.3 液晶校正系統與校正曲線 ... 20 2.2.4 流量 計校正 ... 25 2.3 實驗步驟 ... 27 2.4 研究方法 ... 28 第三章 數據分 析 ... 36 3.1特徵尺寸 ... 36 3.2截面帄均容積溫度 ... 37 3.3壓力係 數Cp與摩擦因子f ... 38 3.4科本因子 ... 39 第四章 結果與討論 ... 40 4.1 帄均紐賽數結果 ... 40 4.2 局部紐賽數結果 ... 41 4.2.1褶紋角30度之結果 ... 41 4.2.2褶紋角45度之結果 ... 42 4.2.3褶紋角60度之結果 ... 43 4.3 雷諾數影響 ... 44 4.4 褶紋角影響 ... 45 4.5 壓降係數與壓降因子 ... 47 4.6 j/f ... 48 4.7 實驗數值不準度分析 ... 49 第五章 結論 ... 50 參考文獻 ... 53 附錄一 ... 136 附錄二 ... 152 附錄三 ... 155 REFERENCES
【1】 Shah, R.K., and Focke, W.W., 1988, “Plate Heat Exchangers and Their Design Theory,” Heat Transfer Design, R.K. Shah, E.C.
Subbarao, and R.A. Mashelkar, eds. Washington, D.C. Hemisphere Publishing Co., pp. 227-254. 【2】 Marriott, J., 1971, “Where and How To Use Plate Heat Exchangers,” Chemical Engineering, April 5, pp. 127-134. 【3】 Focke, W.W., Zacharirades, J., and Olivier, I., 1985, “The Effects of the Corrugation Inclination Angle on the Thermal-Hydraulic Performance of Plate Heat Exchanger,” Int. J. Heat and Mass Transfer, Vol. 28, No. 8, pp. 1469-1479. 【4】 Focke, W.W., and Knibbe, P.G., 1986, “Flow Visualization in Parallel-Plate Ducts with Corrugated Walls,
” J. Fluid Mech., Vol. 165, pp. 73-77. 【5】 Heavner, R.L., Kumar, H., and Wannizrachi, A.S., 1993,“Performance of an Industrial Plate Heat Exchanger: Effect of Chevron Angle,” AICHE, Symp., Vol.89, No. 295, pp. 65-70. 【6】 Bond, M.P., 1981, “Plate Heat Exchanger for
Effective Heat Transfer,” The Chemical Engineer, Vol. 367, pp. 162-166. 【7】 Ros, S., Jallut, C., Grillot, J.M., and Amblard, 1995, “A Transient-State Technique for the Heat Transfer Coefficient Measurement in a Corrugated Plate Heat Exchanger Channel Based on Frequency Response and Residence Time Distribution,” Int. J. Heat Mass Transfer, Vol. 38, No. 7, pp. 1317-1325. 【8】 Ding, J., and Manglik, R.M., 1996, “Analytical Solutions for Laminar Fully Developed Flows in Double-Sine Shaped Ducts,” Heat and Mass Transfer, Vol. 31, pp. 269-277.
【9】 Manglik, R.M., and Ding, J.,1996, “Laminar Flow Heat Transfer to Viscous Power-law Fluids in Double-sine Ducts,” Heat and Mass Transfer, Vol. 31, pp. 269-277. 【10】Mehrabian, M.A., and Poulter, R., 2000, “Hydrodynamics and Thermal Characteristics of Corrugated Channel : Computational Approach,” Applied Mathematical Modeling, Vol. 24, pp. 343-364. 【11】Jang, J.Y., and Lin, C.N., 2000, “A Numerical Analysis of Three-Dimensional Heat Transfer and Fluid Flow in Chevron Plate Channels,” ASHRAE Transactions: Symposia, Minnesota, pp. 856-863. 【12】Fischer, L., and Martin, H., 1997, “Friction Factors for Fully Developed Laminar Flow in Ducts Confined by Corrugated Parallel Walls,” Int. J. Heat and Mass Transfer, Vol. 40, No. 3, pp. 635-639. 【13】Ciofalo, M., Collins, M.W., Stasiek, J.A., 1998,
“Flow and Heat Transfer Predictions in Flow Passages of Air Preheaters:Assessment of Alternative Modeling Approaches,” In:Computer Simulations in Compact Heat Exchangers, Eds. B. Sunden, M.Faghri, Computational Mechanics Publ. U.K. 【14】Paras, S.V., Kanaris, A.G., Mouza, A.A., Karabelas, A.J., 2002, “CFD Code Application to Flow Through Narrow Channels with Corrugated Walls,” CHISA, 15th International Congress of Chemical and Process Engineering, Prague. 【15】Kanaris, A.G., Mouza, K.A., Paras, S.V., 2004, “Designing Novel Compact Heat Exchangers for Improved Efficiency using a CFD Code,” 1st International Conference. 【16】Vlasogiannis, P., Karagiannis, G., Argyropoulos, P., Bontozaglou, V., 2002, “Air-Water Two-Phase Flow and Heat Transfer in a Plate Heat Exchanger”, Int. J. Multiphase Flow, pp. 757-772. 【17】Muely, A., and Manglik, R.M., 1999a, “Experimental Study of Turbulent Flow Heat Transfer and Pressure Drop in a Plate Heat Exchanger With Chevron Plates,” ASME Journal of Heat Transfer, Vol.121, pp.110-117. 【18】Muely, A., Manglik, R.M., and Metwally, H.M., 1999b, “Enhanced Heat Transfer Characteristics of Viscous Liquid Flows in a Chevron Plate Heat Exchanger,” ASME Journal of Heat Transfer, Vol.121, pp.1011-1017. 【19】林佩芝,1995,“幾何參數對板式熱交換器性能之影響”,國立交通大學機械工程研究所 碩士論文。 【20】黃慶初,張永鵬,黃錦文,楊秉純,2000,“以潤滑油為工作流體對板式熱交換器影響之分析”,技術學刊,第13 卷,第2期,第229-236頁。 【21】張嘉宏,2005,“正弦截面曲線波形板流道熱傳係數的暫態液晶量測”,大葉大學機械工程學研究所 碩士論文。 【22】陳立昀,2005,“波形板流道熱傳與壓降的三維數值模擬”,大葉大學機械工程學研究所碩士論文。 【23】王啟川
,2001,“板式熱交換器”,冷凍與空調,第七期,第53-77頁。 【24】Liu,F.B.,and Tsai,Y.C.,2010, “An experimental and numerical investigation of fluid flow in a cross-corrugated channel,” Heat and Mass Transfer,Vol.46,pp.585-593. 【25】Lozano, A., Barreras, F., Fueye, N., and Santodomingo, s., 2008, “The flow in an oil/water plate heat exchanger for the automotive industry,” Applied Thermal Engineering ,Vol.
28, pp. 1109-1117. 【26】Croce, G. and D’Agaro, P.,2002, “Numerical analysis of forced convection in plate and frame heat exchangers,”
International Journal of Numerical Methods for Heat and Fluid Flow, Vol. 12, No.6,pp.756-771. 【27】孟繁宇,2011,“水-空氣在板式熱交 換器內的流動觀察”,國立中央大學能源工程研究所碩士論文。 【28】Robert J. Moffat,1988, “Describing the Uncertainties in
Experimental Results,” Experimental Thermal and Fluid Science, Vol.1 ,pp.3-17.