6 6 REPLACING ANALOG I/O MODULE

6.1 List of Alternative Analog I/O Module Models

MELSECNET/MINI-S3, A2C models

to be discontinued Replacement to CC-Link

Product name Model name Model name Remarks (restrictions)

Analog input

module A68ADC

AJ65BT-64AD

1) Change in external wiring: Wiring change due to differences in terminal blocks, communication cable change to CC-Link dedicated cable, applicable wire size of signal lead change

2) Change in number of modules: Required (2 modules necessary)

3) Change in program: Change to programs for CC-Link 4) Change in performance specifications: 4CH/module 5) Change in functional specifications: Not required 6) Change in dimensions for mounting the panel:

Required

AJ65SBT2B-64AD AJ65SBT-64AD

1) Change in external wiring: Wiring change due to differences in terminal blocks, communication cable change to CC-Link dedicated cable, applicable wire size of signal lead change

2) Change in number of modules: Required (2 modules necessary)

3) Change in program: Change to programs for CC-Link 4) Change in performance specifications: 4CH/module,

negative current conversion not possible

5) Change in functional specifications: An averaging processing function of the AJ65SBT-64AD can handle only a moving averaging processing.

6) Change in dimensions for mounting the panel:

Required

AJ65VBTCU-68ADVN

1) Change in external wiring: Wiring change due to differences in terminal blocks, communication cable change to CC-Link dedicated cable, applicable wire size of signal lead change

2) Change in number of modules: Not required 3) Change in program: Change to programs for CC-Link 4) Change in performance specifications: Voltage input

only

5) Change in functional specifications: Not required 6) Change in dimensions for mounting the panel:

6 REPLACING ANALOG I/O MODULE

Analog input

module A68ADC AJ65VBTCU-68ADIN

1) Change in external wiring: Wiring change due to differences in terminal blocks, communication cable change to CC-Link dedicated cable, applicable wire size of signal lead change

2) Change in number of modules: Not required 3) Change in program: Change to programs for CC-Link 4) Change in performance specifications: Current input

only

5) Change in functional specifications: Not required 6) Change in dimensions for mounting the panel:

Required

Analog output

module A64DAVC

AJ65SBT2B-64DA AJ65BT-64DAV

1) Change in external wiring: Wiring change due to differences in terminal blocks, communication cable change to CC-Link dedicated cable, applicable wire size of signal lead change

2) Change in number of modules: Not required 3) Change in program: Change to programs for CC-Link 4) Change in performance specifications: Change in

resolution

5) Change in functional specifications: Not required 6) Change in dimensions for mounting the panel:

Required

AJ65SBT-62DA

1) Change in external wiring: Wiring change due to differences in terminal blocks, communication cable change to CC-Link dedicated cable, applicable wire size of signal lead change

2) Change in number of modules: Required (2 modules necessary)

3) Change in program: Change to programs for CC-Link 4) Change in performance specifications: Change in

resolution

5) Change in functional specifications: 2CH/module 6) Change in dimensions for mounting the panel:

Required

AJ65VBTCU-68DAVN

1) Change in external wiring: Wiring change due to differences in terminal blocks, communication cable change to CC-Link dedicated cable, applicable wire size of signal lead change

2) Change in number of modules: Not required 3) Change in program: Change to programs for CC-Link 4) Change in performance specifications: 8CH/module 5) Change in functional specifications: Not required 6) Change in dimensions for mounting the panel:

Required MELSECNET/MINI-S3, A2C models

to be discontinued Replacement to CC-Link

Product name Model name Model name Remarks (restrictions)

6 REPLACING ANALOG I/O MODULE

Analog output

module A64DAIC

AJ65SBT2B-64DA AJ65BT-64DAI

1) Change in external wiring: Wiring change due to differences in terminal blocks, communication cable change to CC-Link dedicated cable, applicable wire size of signal lead change

2) Change in number of modules: Not required 3) Change in program: Change to programs for CC-Link 4) Change in performance specifications: Upward

compatible

5) Change in functional specifications: Not required 6) Change in dimensions for mounting the panel:

Required

AJ65SBT-62DA

1) Change in external wiring: Wiring change due to differences in terminal blocks, communication cable change to CC-Link dedicated cable, applicable wire size of signal lead change

2) Change in number of modules: Required (2 modules necessary)

3) Change in program: Change to programs for CC-Link 4) Change in performance specifications: Change in

resolution

5) Change in functional specifications: 2CH/module 6) Change in dimensions for mounting the panel:

Required

Temperature input module

A64RD3C AJ65SBT2B-64RD3

AJ65BT-64RD3

1) Change in external wiring: Wiring change due to differences in terminal blocks, communication cable change to CC-Link dedicated cable, applicable wire size of signal lead change

2) Change in number of modules: Not required 3) Change in program: Change to programs for CC-Link 4) Change in performance specifications: Change in

temperature detecting output current, change in resistive values of allowable conductor

5) Change in functional specifications: Not required 6) Change in dimensions for mounting the panel:

Required

A64RD4C AJ65BT-64RD4

1) Change in external wiring: Wiring change due to differences in terminal blocks, communication cable change to CC-Link dedicated cable, applicable wire size of signal lead change

2) Change in number of modules: Not required 3) Change in program: Change to programs for CC-Link 4) Change in performance specifications: Change in

temperature detecting output current, change in resistive values of allowable conductor

5) Changes in functional specifications: Change in the specifications of the line breakage detection function 6) Change in dimensions for mounting the panel:

Required MELSECNET/MINI-S3, A2C models

to be discontinued Replacement to CC-Link

Product name Model name Model name Remarks (restrictions)

6 REPLACING ANALOG I/O MODULE

6.2.1 Comparisons of analog input module

(1) Comparisons between A68ADC and AJ65BT-64AD (a) Performance specifications comparisons

: Compatible, : Partial change required, : Not compatible

6.2 List of Alternative Master Module Models

Item A68ADC AJ65BT-64AD

Compati-bility

Precautions for replacement

Analog input

Voltage: -10 to 0 to +10VDC (input resistance 30K )

Current: +4 to +20mA (input resistance 250 )

Select via input terminal

* Current input can also be used as -20 to 0 to +20mA.

Voltage: -10 to 0 to +10VDC (input resistance 1M ) Current: -20 to 0 to +20mA

(input resistance 250 ) (select via input terminal)

Digital output

16bits signed binary (data part 11bits)

-2048 to 2047

16bits signed binary (data part 12bits)

I/O characteristics

Analog input value Digital output value -10 to 10V or -2000 to 2000

0 to 4000 or -2000 to 2000

0 to 4000 or -2000 to 2000

0 to 4000 or -2000 to 2000

Precautions are needed as gain values are different.

Maximum resolution Voltage 5mV (1/2000) Current 20 A (1/1000)

Analog input value Resolution -10 to 10V or

Overall accuracy Within 1% ( 20)

(accuracy relative to maximum value) 1%( 40)

Maximum conversion

speed Max. 2.5ms/channel 1ms/channel

Absolute maximum

input Voltage 15V, current 30mA

Analog input 8 channels/module 4 channels/module

Please consider replacing by using two or more AJ65BT-64AD Analog input Digital output

+10V +2000

+5V or +20mA +1000

0V or +4mA 0

-5V or

-12mA -1000

-10V -2000

6 REPLACING ANALOG I/O MODULE

: Compatible, : Partial change required, : Not compatible

Item A68ADC AJ65BT-64AD

Compati-bility

Precautions for replacement

Number of occupied I/O stations (number of points)

4 stations (4 stations 8 points) 2 stations (2 stations 32 points) (RX/RY 32 points each, RWr/RWw 8 points each)

The number of occupied points increases. The assignment of the entire system needs to be reconsidered.

Connected terminal 47-point terminal block 27-point terminal block

Change in wiring is required.

Applicable wire size 0.75 to 2mm2 (applicable tightening torque 7kg cm) Applicable solderless

terminal

V1.25-3, V1.25-YS3A,

V2-S3, V2-YS3A RAV1.25-3.5, RAV2-3.5

24VDC internal current consumption

0.3A 0.12A

Weight 1.01kg 0.35kg

External dimensions 170(H) 100(W) 80(D)mm 65(H) 151.9(W) 63(D)mm

The overall size differs.

Pay attention to the mounting dimensions.

6 REPLACING ANALOG I/O MODULE