5 5 REPLACING I/O MODULE
5.1 List of Alternative I/O Module Models
MELSECNET/MINI-S3, A2C models
to be discontinued Alternative model for CC-Link
Product name Model name Model name Remarks (restrictions)
Input module
AX11C AJ65SBTB2N-16A
1) Change in external wiring: Required
2) Change in number of modules (2 modules necessary) 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated input voltage: Not required Change in rated input current: Required Change in ON voltage/ON current: Not required Change in OFF voltage/OFF current: Required Change in input resistance: Required
5) Change in functions: Required (2-wire type for inputs)
AX21C None
No alternative model
• Please consider using the FA goods
FA-TH16X200A31L. (The FA goods are manufactured by Mitsubishi Electric Engineering Co., Ltd.) The 24VDC input module for CC-Link (AJ65SBTCF1-32D) is required to use the FA goods.
AX31C AJ65SBTB1-32D
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Not required 4) Change in specifications
Change in rated input voltage: Required (12/24VAC, 12VDC not allowed)
Change in rated input current: Not required Change in ON voltage/ON current: Required Change in OFF voltage/OFF current: Required Change in input resistance: Required Change in input response time: Required
(35/30ms 1.5ms)
5) Change in functions: Required (12/24VAC, 12VDC not allowed)
5 REPLACING I/O MODULE
Input module
AJ35PTF-32A*1 AJ65SBTB2N-16A
1) Change in external wiring: Required
2) Change in number of modules (2 modules necessary) 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated input voltage: Not required Change in rated input current: Required Change in ON voltage/ON current: Required Change in OFF voltage/OFF current: Required Change in input resistance: Required
5) Change in functions: Required (2-wire type for inputs)
AX41C AJ65SBTB1-32D
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Not required 4) Change in specifications
Change in rated input voltage: Required (12VDC not allowed)
Change in rated input current: Not required Change in ON voltage/ON current: Required Change in OFF voltage/OFF current: Required Change in input resistance: Not required Change in input response time: Required
(10ms 1.5ms)
5) Change in functions: Required (12VDC not allowed) MELSECNET/MINI-S3, A2C models
to be discontinued Alternative model for CC-Link
Product name Model name Model name Remarks (restrictions)
5 REPLACING I/O MODULE
MELSECNET/MINI-S3, A2C models to be
discontinued Alternative models for CC-Link
Product name Model name Model name Remarks (restrictions)
Input module
AX41C AJ65DBTB1-32D
1) Change in external wiring: Required (Communication cable and power cable only)
2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Not required
4) Change in specifications
Change in rated input voltage: Required (12VDC not allowed)
Change in rated input current: Required Change in ON voltage/ON current: Required Change in OFF voltage/OFF current: Required Change in input resistance: Required Change in input response time: Not required 5) Change in functions: Required (12VDC not allowed)
AX81C
AJ65SBTB1-32D
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Not required
4) Change in specifications
Change in rated input voltage: Required (12VDC not allowed)
Change in rated input current: Not required Change in ON voltage/ON current: Required Change in OFF voltage/OFF current: Required Change in input resistance: Not required Change in input response time: Required
(10ms 1.5ms)
5) Change in functions: Required (12VDC not allowed)
AJ65DBTB1-32D
1) Change in external wiring: Required (Communication cable and power cable only)
2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Not required
4) Change in specifications
Change in rated input voltage: Required (12VDC not allowed)
Change in rated input current: Required Change in ON voltage/ON current: Required Change in OFF voltage/OFF current: Required Change in input resistance: Required Change in input response time: Not required 5) Change in functions: Required (12VDC not allowed)
5 REPLACING I/O MODULE
Input module
AJ35PTF-32D*1 AJ65SBTB1-32D
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Not required
4) Change in specifications
Change in rated input voltage: Required (12VDC not allowed)
Change in rated input current: Required Change in ON voltage/ON current: Required Change in OFF voltage/OFF current: Required Change in input resistance: Not required Change in input response time: Required
(10ms 1.5ms)
5) Change in functions: Required (12VDC not allowed, no optics)
AJ35TB1-16A AJ65SBTB2N-16A
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated input voltage: Not required Change in rated input current: Required Change in ON voltage/ON current: Not required Change in OFF voltage/OFF current: Required Change in input resistance: Required
5) Change in functions: Required (2-wire type for inputs)
AJ35TB2-8D AJ65SBTB3-8D
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated input voltage: Not required Change in rated input current: Not required Change in ON voltage/ON current: Not required Change in OFF voltage/OFF current: Not required Change in input resistance: Not required
Change in input response time: Required (10ms 1.5ms)
5) Change in functions: Required (2-wire type 3-wire type)
AJ35TB3-8D AJ65SBTB3-8D
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated input voltage: Not required Change in rated input current: Not required Change in ON voltage/ON current: Not required Change in OFF voltage/OFF current: Not required Change in input resistance: Not required MELSECNET/MINI-S3, A2C models to be
discontinued Alternative models for CC-Link
Product name Model name Model name Remarks (restrictions)
5 REPLACING I/O MODULE
Input module AJ35TB1-16D AJ65SBTB1-16D
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated input voltage: Not required Change in rated input current: Not required Change in ON voltage/ON current: Not required Change in OFF voltage/OFF current: Not required Change in input resistance: Not required Change in input response time: Required
(10ms 1.5ms)
5) Change in functions: Not required MELSECNET/MINI-S3, A2C models to be
discontinued Alternative models for CC-Link
Product name Model name Model name Remarks (restrictions)
5 REPLACING I/O MODULE
MELSECNET/MINI-S3, A2C models
to be discontinued Alternative models for CC-Link
Product name Model name Model name Remarks (restrictions)
Input module
AJ35TB1-16D AJ65BTB1-16D
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated input voltage: Not required Change in rated input current: Not required Change in ON voltage/ON current: Not required Change in OFF voltage/OFF current: Not required Change in input resistance: Not required Change in input response time: Not required 5) Change in functions: Not required
AJ35TB2-16D
AJ65SBTB3-16D
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated input voltage: Not required Change in rated input current: Not required Change in ON voltage/ON current: Not required Change in OFF voltage/OFF current: Not required Change in input resistance: Not required Change in input response time: Required
(10ms 1.5ms)
5) Change in functions: Required (2-wire type 3-wire type)
AJ65BTB2-16D
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated input voltage: Not required Change in rated input current: Not required Change in ON voltage/ON current: Not required Change in OFF voltage/OFF current: Not required Change in input resistance: Not required Change in input response time: Not required 5) Change in functions: Not required
AJ35TC1-32D AJ65SBTCF1-32D
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Not required
4) Change in specifications
Change in rated input voltage: Not required Change in rated input current: Not required Change in ON voltage/ON current: Required Change in OFF voltage/OFF current: Not required Change in input resistance: Not required Change in input response time: Required
(10ms 1.5ms)
5 REPLACING I/O MODULE
Output module
AY13C
AJ65SBTB2N-16R
1) Change in external wiring: Required
2) Change in number of modules (2 modules necessary) 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated output voltage: Not required Change in rated output current: Not required 5) Change in functions: Required
(2-wire type for outputs)
AJ65DBTB1-32R
1) Change in external wiring: Required (Communication cable and power cable only)
2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Not required
4) Change in specifications
Change in rated output voltage: Not required Change in rated output current: Not required 5) Change in functions: Not required
AY15CEU
AJ65SBTB2N-16R
1) Change in external wiring: Required
2) Change in number of modules (2 modules necessary) 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated output voltage: Not required Change in rated output current: Not required
(Note that a connect life is half.) 5) Change in functions: Required
(2-wire type for outputs)
AJ65DBTB1-32R
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: : Not required
4) Change in specifications
Change in rated output voltage: Not required Change in rated output current: Not required 5) Change in functions: Not required
AY23C AJ65SBTB2N-16S
1) Change in external wiring: Required
2) Change in number of modules (2 modules necessary) 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated output voltage: Not required Change in rated output current: Required 5) Change in functions: Required
(2-wire type for outputs)
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Not MELSECNET/MINI-S3, A2C models
to be discontinued Alternative models for CC-Link
Product name Model name Model name Remarks (restrictions)
5 REPLACING I/O MODULE
Output module
AY51C AJ65DBTB1-32T1
1) Change in external wiring: Required (Communication cable and power cable only)
2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Not required
4) Change in specifications
Change in rated output voltage: Not required Change in rated output current: Required 5) Change in functions: Not required
AY61CE
AJ65SBTB1-16TE
1) Change in external wiring: Required
2) Change in number of modules (2 modules necessary) 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated output voltage: Required (5VDC not allowed)
Change in rated output current: Required (2A 0.1A) 5) Change in functions: Required (5VDC not allowed)
AJ65SBTB1-32TE1
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Not required
4) Change in specifications
Change in rated output voltage: Required (5VDC not allowed)
Change in rated output current: Required (2A 0.5A) 5) Change in functions: Required (5VDC not allowed)
AY81C
AJ65SBTB1-16TE
1) Change in external wiring: Required
2) Change in number of modules (2 modules necessary) 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated output voltage: Required Change in rated output current: Required
(0.5A 0.1A)
5) Change in functions: Not required
AJ65SBTB1-32TE1
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Not required
4) Change in specifications
Change in rated output voltage: Not required Change in rated output current: Not required 5) Change in functions: Not required
1) Change in external wiring: Required
2) Change in number of modules (2 modules necessary) 3) Change in program
Change in number of occupied I/O points: Required MELSECNET/MINI-S3, A2C models
to be discontinued Alternative models for CC-Link
Product name Model name Model name Remarks (restrictions)
5 REPLACING I/O MODULE
MELSECNET/MINI-S3, A2C models
to be discontinued Alternative models for CC-Link
Product name Model name Model name Remarks (restrictions)
Output module
AJ35PTF-24T*1 AJ65SBTB1-32T1
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated output voltage: Not required Change in rated output current: Not required 5) Change in functions: Required (no optics)
AJ35TB1A-8R AJ65SBTB2N-8R
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated output voltage: Not required Change in rated output current: Not required 5) Change in functions: Required
(Change to 16 points per common (2-wire type))
AJ35TB2-8R AJ65SBTB2N-8R
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated output voltage: Not required Change in rated output current: Not required 5) Change in functions: Not required
AJ35TB1-16R AJ65SBTB2N-16R
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated output voltage: Not required Change in rated output current: Not required 5) Change in functions: Required
(2-wire type for outputs)
AJ35TB1A-8T AJ65SBTB1-8T1
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated output voltage: Required Change in rated output current: Required 5) Change in functions: Required
(Change to 16 points per common (2-wire type) )
AJ35TB2-8T AJ65SBTB2-8T1
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated input voltage: Required (5VDC not allowed)
Change in rated output current: Not required
5 REPLACING I/O MODULE
*1: Replacement using renewal tool for A0J2 is possible (refer to Appendix 2).
MELSECNET/MINI-S3, A2C models
to be discontinued Alternative model for CC-Link
Product name Model name Model name Remarks (restrictions)
Output module
AJ35TB1-16T
AJ65SBTB1-16T1
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated output voltage: Required Change in rated output current: Required 5) Change in functions: Not required
AJ65BTB1-16T
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated output voltage: Not required Change in rated output current: Not required 5) Change in functions: Not required
AJ35TB2-16T AJ65SBTB2-16T1
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated output voltage: Required Change in rated output current: Required 5) Change in functions: Not required
AJ35TC1-32T AJ65SBTCF1-32T
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Not required
4) Change in specifications
Change in rated output voltage: Required Change in rated output current: Not required 5) Change in functions: Not required
6) Others: External wiring connectors not attached
AJ35PTF-24R*1 AJ65SBTB2N-16R
1) Change in external wiring: Required
2) Change in number of modules: Required (2 modules necessary)
3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated output voltage: Not required Change in rated output current: Not required 5) Change in functions: Required (2-wire type for
outputs, no optics)
5 REPLACING I/O MODULE
MELSECNET/MINI-S3, A2C models
to be discontinued Alternative model for CC-Link
Product name Model name Model name Remarks (restrictions)
I/O module
AX10Y10C
AJ65SBTB2N-16A + AJ65SBTB2N-16R
1) Change in external wiring: Required
2) Change in number of modules (2 modules necessary) 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated input voltage: Not required Change in rated input current: Required Change in ON voltage/ON current: Not required Change in OFF voltage/OFF current: Required Change in input resistance: Required Change in rated output voltage: Not required Change in rated output current: Not required 5) Change in functions: Required (2-wire type for I/Os)
AX10Y22C
AJ65SBTB2N-16A + AJ65SBTB2N-16S
1) Change in external wiring: Required
2) Change in number of modules (2 modules necessary) 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated input voltage: Not required Change in rated input current: Required Change in ON voltage/ON current: Not required Change in OFF voltage/OFF current: Required Change in input resistance: Required Change in rated output voltage: Not required Change in rated output current: Required
5) Change in functions: Required (2-wire type for I/Os)
5 REPLACING I/O MODULE
MELSECNET/MINI-S3, A2C models
to be discontinued Alternative models for CC-Link
Product name Model name Model name Remarks (restrictions)
I/O module
AX40Y10C
AJ65SBTB1-16D + AJ65SBTB2N-16R
1) Change in external wiring: Required
2) Change in number of modules (2 modules necessary) 3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated input voltage: Required (12VDC not allowed)
Change in rated input current: Required Change in ON voltage/ON current: Required Change in OFF voltage/OFF current: Required Change in input resistance: Not required Change in input response time: Required
(10ms 1.5ms)
Change in rated output voltage: Not required Change in rated output current: Not required 5) Change in functions: Required
(2-wire type for outputs, 12VDC not allowed)
AJ65SBTB32-16DR
1) Change in external wiring: Required
2) Change in number of modules: Required (2 modules necessary)
3) Change in program
Change in number of occupied I/O points: Required 4) Change in specifications
Change in rated input voltage: Required (12VDC not allowed)
Change in rated input current: Required Change in ON voltage/ON current: Required Change in OFF voltage/OFF current: Required Change in input resistance: Not required Change in rated output voltage: Not required Change in rated output current: Not required 5) Change in functions: Required (12VDC not allowed)
AX40Y10C AJ65DBTB1-32DR
1) Change in external wiring: Required (Communication cable and power cable only)
2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Not required
4) Change in specifications
Change in rated input voltage: Required (12VDC not allowed)
Change in rated input current: Required Change in ON voltage/ON current: Required Change in OFF voltage/OFF current: Required Change in input resistance: Required Change in rated output voltage: Not required Change in rated output current: Not required 5) Change in functions: Required (12VDC not allowed)
5 REPLACING I/O MODULE
I/O module AX40Y50C
AJ65SBTB1-32DT2
1) Change in external wiring: Required 2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Not required
4) Change in specifications
Change in rated input voltage: Required (12VDC not allowed)
Change in rated input current: Required Change in ON voltage/ON current: Required Change in OFF voltage/OFF current: Required Change in input resistance: Not required Change in input response time: Required (10ms 1.5ms)
Change in rated output voltage: Required (12VDC not allowed)
Change in rated output current: Required
5) Change in functions: Required (12VDC not allowed)
AJ65DBTB1-32DT1
1) Change in external wiring: Required (Communication cable and power cable only)
2) Change in number of modules: Not required 3) Change in program
Change in number of occupied I/O points: Not
Change in number of occupied I/O points: Not