(1) System configurations and connection conditions

The following system configurations and connection conditions assume bus connection with the QCPU (Q mode). The numbers ( to ) given in the system configurations denote the numbers ( to ) in "(2) System equipment". Refer to these numbers when you want to confirm the types and applications.

POINT

• Up to five GOTs may be connected.

• Select the connection cables whose lengths satisfy the conditions of the maximum distance depending on the connection conditions.

• Installing the first connected GOT more than 13.2m away requires the bus extension connector box . When the Q00JCPU is used, however, the bus extension connector box 3 cannot be used and the GOT should therefore be installed within 13.2m.

Connection Conditions Number of

connected

Installation distance

System Configuration

Within 13.2m

Max. 13.2m*1

Connection cable

1 GOT

More than 13.2m

Max. 37m*1

To use the bus extension connector box, fit it to the extension connector of the base unit.

Plug the connection cable into the bus extension connector box.

Connection cable Bus

extension connector box

*2

*1 Also includes the extension cable length (between [base unit] and [base unit]) when the extension base unit is used.

*2 When not using the extension base unit: Fit it to the main base unit.

When using the extension base unit: Fit it to the extension base unit on the last stage.

Connection Conditions Number of

connected

Installation distance

System Configuration

First GOT within 13.2m

Max. 37m Max. 13.2m*1

Connection cable Connection cable Connection cable

2 to 5 GOTs

First GOT more than 13.2m

To use the bus extension connector box, fit it to the extension connector of the base unit.

Plug the connection cable into the bus extension connector box.

Bus extension connector box

Max. 37m*1

Connection cable Connection cable Connection cable

*2

*1 Also includes the extension cable length (between [base unit] and [base unit]) when the extension base unit is used.

*2 When not using the extension base unit: Fit it to the main base unit.

When using the extension base unit: Fit it to the extension base unit on the last stage.

The following table indicates the system equipment needed for connection with the QCPU (Q mode).

Type

Image No. Application

GOT unit Bus connection

board*1*2

Bus connection unit*1*2 A985GOT(-V), A97*GOT, A960GOT A9GT-QBUSS,

A9GT-QBUS2S A9GT-QBUS2SU*4

A956WGOT A9GT-50WQBUSS A9GT-QBUS2SU

A956GOT ——— A9GT-QBUS2SU

Bus-connected GOT at termination

A951GOT-Q

(with built-in communication interface) ——— A9GT-QBUS2SU*4 A985GOT(-V), A97*GOT, A960GOT A9GT-QBUS2S ———

A956WGOT ——— A9GT-QBUS2SU

Bus-connected GOT at midpoint

A956GOT ——— A9GT-QBUS2SU

Unit for extension of distance

between [GOT] and [base unit]*3 A9GT-QCNB Connection cable between [base

unit] and [GOT]

QC06B(0.6m), QC12B(1.2m), QC30B(3.0m),

QC50B(5.0m), QC100B(10.0m) Connection cable between [bus

extension connector box] and [GOT]

QC06B(0.6m), QC12B(1.2m), QC30B(3.0m),

QC50B(5.0m), QC100B(10.0m), A9GT-QC150BS(15.0m), A9GT-QC200BS(20.0m), A9GT-QC250BS(25.0m), A9GT-QC300BS(30.0m)

*1 There are the following differences between the bus connection board and bus connection unit.

A9GT- BUSS(U) : Has one interface and usable with the GOT at termination. (Unusable with the GOT at midpoint) A9GT- BUS2S(U) : Has two interfaces and usable with the GOT at termination and the GOT at midpoint.

*2 A single GOT does not accept multiple bus connection units and bus connection boards.

*3 For the system configuration using the QCNB, the same extension number as set to the GOT must be set to the A9GT-QCNB. Refer to Section 3.3 for the extension number setting.

*4 The GOT of the following hardware version is applicable.

GOT Hardware version

A985GOT-TBA/TBD-V Hardware version C (Jan., 2001) or later

A985GOT-TBD Hardware version N (Jan., 2001) or later

A985GOT-TBA Hardware version J (Jan., 2001) or later

A975GOT-TBA/TBD(-B) Hardware version G (Jan., 2001) or later

A970GOT-SBA/SBD/LBA/LBD/TBA(-B)/TBD(-B) Hardware version G (Jan., 2001) or later

A960GOT-EBA/EBD Hardware version D (Jan., 2001) or later

3.2.2 Connection with QnACPU (large type) or ACPU (large type)

(1) System configurations and connection conditions

The following system configurations and connection conditions assume bus connection with the QnACPU (large type) or ACPU (large type).

The numbers ( to ) given in the system configurations denote the numbers ( to ) in "(2) System equipment". Refer to these numbers when you want to confirm the types and applications.

POINT

• Up to three GOTs may be connected.

• Select the connection cables whose lengths satisfy the conditions of the maximum distance depending on the connection conditions.

• Installing the first connected GOT more than 6.6m away requires the bus connector conversion box .

Connection Conditions Number of

connected Installation distance

System Configuration

Within 6.6m

Max. 6.6m*1

Connection cable

1 GOT

More than 6.6m

Max. 6.6m

Max. 36.6m

*1

Bus connector conversion box

Connection cable Connection cable

First GOT within 6.6m

Max. 6.6m

Max. 36.6m

* 1

Connection cable Connection cable

2 GOTs

First GOT more than

6.6m Max. 6.6m

Max. 36.6m

*1 Max. 30m

Bus connector conversion box

Connection cable

Connection cable Connection cable

3 GOTs First GOT within 6.6m

Max. 6.6m

Max. 36.6m

*1 Max. 30m

Connection cable Connection cable Connection cable

*1 Also includes the extension cable length (between [base unit] and [base unit]) when the extension base unit is used.

The following table indicates the system equipment needed for connection with the QnACPU (large type) or ACPU (large type).

Type

Image No. Application

GOT unit Bus connection

board*1*2

Bus connection unit*1*2 A985GOT(-V), A97*GOT, A960GOT A9GT-BUSS,

A9GT-BUS2S

A9GT-BUSSU, A9GT-BUS2SU

A956WGOT A9GT-50WBUSS A9GT-BUSSU,

A9GT-BUS2SU Bus-connected GOT at

termination

A951GOT

(with built-in communication interface) ——— ———

A985GOT(-V), A97*GOT, A960GOT A9GT-BUS2S A9GT-BUS2SU

A956WGOT A9GT-BUS2SU

Bus-connected GOT at midpoint

A956GOT A9GT-BUS2SU,

A7GT-BUS2S Unit for conversion of

connection cable connectors and also for extension of distance between [GOT] and [base unit]

A7GT-CNB

Connection cable between

[base unit] and [GOT] A8GT-C12NB(1.2m), A8GT-C30NB(3m), A8GT-C50NB(5m) Connection cable between

[bus connector conversion box]

and [GOT] *3*4*5

A8GT-C100EXSS(10m), A8GT-C200EXSS(20m), A8GT-C300EXSS(30m) A8GT-C100EXSS-1(10m), A8GT-C200EXSS-1(20m), A8GT-C300EXSS-1(30m) Connection cable between

[base unit] and [bus connector conversion box]

AC06B(0.6m), AC12B(1.2m), AC12B-R(1.2m),

AC30B(3m), AC30B-R(3m), AC50B(5m),

AC50B-R(5m) Connection cable between

[GOT] and [GOT] *4

A1SC07B(0.7m), A1SC12B(1.2m), A1SC30B(3m), A1SC50B(5m), A8GT-C100BS(10m), A8GT-C200BS(20m), A8GT-C300BS(30m)

*1 There are the following differences between the bus connection board and bus connection unit.

A9GT-BUSS(U) : Has one interface and usable with the GOT at termination. (Unusable with the GOT at midpoint) A9GT-BUS2S(U) : Has two interfaces and usable with the GOT at termination and the GOT at midpoint.

*2 A single GOT does not accept multiple bus connection units and bus connection boards.

*3 When using the bus connection cable (A8GT-C100EXSS, A8GT-C200EXSS, A8GT-C300EXSS), connect the connection cable connectors as indicated below.

Connector "COM1" PLC CPU side Connector "COM2" GOT side

*4 When using the bus connection cable (C100EXSS, C200EXSS, C300EXSS, C100BS, A8GT-C200BS, A8GT-C300BS), always connect the ground wires (green wires (1m)) coming out of the connectors at both ends of the cable to the control box or like.

Connect both ground wires to control box or like.

*5 The C100EXSS-1/C200EXSS-1/C300EXSS-1 cable consists of the EXCNB (0.5m) and A8GT-C100BS (10m)/C200BS (20m)/C300BS (30m), respectively.

The length of the A8GT-EXCNB (0.5m) need not be considered when calculating the cable length.

3.2.3 Connection with QnACPU (small type) or ACPU (small type)

(1) System configurations and connection conditions

The following system configurations and connection conditions assume bus connection with the QnACPU (small type) or ACPU (small type).

The numbers ( to ) given in the system configurations denote the numbers ( to ) in "(2) System equipment". Refer to these numbers when you want to confirm the types and applications.

POINT

• Up to three GOTs may be connected.

• Select the connection cables whose lengths satisfy the conditions of the maximum distance depending on the connection conditions.

• Installing a single connected GOT more than 35m away requires the bus connector conversion box .

Connection Conditions Number of

connected

Installation distance

System Configuration

Within 30m

Max. 30m Connection cable

1 GOT

More than 30m

Max. 35m

Connection cable Connection cable

Bus connector conversion box

First GOT within 5m

Max. 35m

Connection cable Connection cable

2 GOTs

First GOT more than 5m

Max. 30m

Connection cable Connection cable

3 GOTs First GOT within 5m

Max. 5m

Max. 35m Max. 30m Connection cable

Connection cable Connection cable

*1 Also includes the extension cable length (between [base unit] and [base unit]) when the extension base unit is used.

The following table indicates the system equipment needed for connection with the QnACPU (small type) or ACPU (small type).

Type

Image No. Application

GOT unit Bus connection

board*1*2

Bus connection unit*1*2 A985GOT(-V), A97*GOT, A960GOT A9GT-BUSS,

A9GT-BUS2S,

A9GT-BUSSU, A9GT-BUS2SU

A956WGOT A9GT-50WBUSS A9GT-BUSSU,

A9GT-BUS2SU Bus-connected GOT at

termination

A951GOT

(with built-in communication interface) ——— ———

A985GOT(-V), A97*GOT, A960GOT A9GT-BUS2S A9GT-BUS2SU

A956WGOT A9GT-BUS2SU

Bus-connected GOT at midpoint

A956GOT A9GT-BUS2SU,

A7GT-BUS2S Unit for conversion of

connection cable connectors and also for extension of distance between [GOT] and [base unit]

A7GT-CNB

Connection cable between [base unit] and [GOT] when only one GOT is connected

*3*5*6

A1SC07B(0.7m), A1SC12B(1.2m), A1SC30B(3m), A1SC50B(5m),

A8GT-C100EXSS(10m), A8GT-C200EXSS(20m), A8GT-C300EXSS(30m) A8GT-C100EXSS-1(10m), A8GT-C200EXSS-1(20m), A8GT-C300EXSS-1(30m) Connection cable between

[bus connector conversion box] and [GOT] *3*5*6

A8GT-C100EXSS(10m), A8GT-C200EXSS(20m), A8GT-C300EXSS(30m) A8GT-C100EXSS-1(10m), A8GT-C200EXSS-1(20m), A8GT-C300EXSS-1(30m) Connection cable between

[base unit] and [bus connector conversion box] *4

A1SC05NB(0.5m), A1SC07NB(0.7m), A1SC30NB(3m), A1SC50NB(5m)

Connection cable between [base unit] and [GOT] when multiple GOTs are connected

A1SC07B(0.7m), A1SC12B(1.2m), A1SC30B(3m), A1SC50B(5m)

Connection cable between [GOT] and [GOT] *5

A1SC07B(0.7m), A1SC12B(1.2m), A1SC30B(3m), A1SC50B(5m),

A8GT-C100BS(10m), A8GT-C200BS(20m), A8GT-C300BS(30m)

*1 There are the following differences between the bus connection board and bus connection unit.

A9GT-BUSS(U) : Has one interface and usable with the GOT at termination. (Unusable with the GOT at midpoint) A9GT-BUS2S(U) : Has two interfaces and usable with the GOT at termination and the GOT at midpoint.

*2 A single GOT does not accept multiple bus connection units and bus connection boards.

*3 When using the bus connection cable (A8GT-C100EXSS, A8GT-C200EXSS, A8GT-C300EXSS), connect the connection cable connectors as indicated below.

Connector "COM1" PLC CPU side Connector "COM2" GOT side

*4 When the extension base unit is used, the sum of cable lengths of the extension cable (between [base unit] and [base unit]) and connection cable (this cable) should be within 6m.

*5 When using the bus connection cable (C100EXSS, C200EXSS, C300EXSS, C100BS, A8GT-C200BS, A8GT-C300BS), always connect the ground wires (green wires (1m)) coming out of the connectors at both ends of the cable to the control box or like.

Connect both ground wires to control box or like.

*6 The C100EXSS-1/C200EXSS-1/C300EXSS-1 cable consists of the EXCNB (0.5m) and A8GT-C100BS (10m)/C200BS (20m)/C300BS (30m), respectively.

The length of the A8GT-EXCNB (0.5m) need not be considered when calculating the cable length.

(1) System configurations and connection conditions

The following system configuration and connection conditions assume bus connection with the A0J2HCPU.

The numbers ( to ) given in the system configurations denote the numbers ( to ) in "(2) System equipment". Refer to these numbers when you want to confirm the types and applications.

POINT

• Up to one GOT may be connected.

Connection Conditions Number of

connected

Installation distance

System Configuration

1 GOT Within 1m

Max. 1m Power supply unit

Connection cable

Connection cable