Regular Article

Experimental estimation of blood

flow velocity through simulation of intravital

microscopic imaging in micro-vessels by different image processing methods

Tzung-Chi Huang

a,

, Wen-Chen Lin

b

, Chih-Chieh Wu

b

, Geoffrey Zhang

c

, Kang-Ping Lin

b

aDepartment of Biomedical Imaging and Radiological Science, China Medical University, Taiwan bDepartment of Electrical Engineering, Chung Yuan University, Taiwan

c

Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL, USA

a b s t r a c t

a r t i c l e i n f o

Article history: Received 27 May 2010 Revised 18 July 2010 Accepted 19 July 2010 Available online 24 July 2010 Keywords:

Red blood cell Bloodflow

Velocity measurement Opticalflow Micro-vessel

Quantization of red blood cell (RBC) velocity in micro-vessel is one of the techniques for dynamic observation of microvascular mechanisms. Theflow measurement of RBC in micro-vessels is still a challenge nowadays. Image processing for velocity measurement using a frame by frame analysis is a common approach. The accuracy of the calculations, which is algorithm dependant, has rarely been examined. In this paper, we evaluated the accuracy of the existing methods, which includes cross correlation method, Hough transform method, and opticalflow method, by applying these methods to simulated micro-vessel image sequences. Simulated experiments in various micro-vessels with random RBC motion were applied in the evaluation. The bloodflow variation in the same micro-vessels with different RBC densities and velocities was considered in the simulations. The calculation accuracy of differentflow patterns and vessel shapes were also examined, respectively. Based on the comparison, the use of an opticalflow method, which is superior to a cross-correlation method or a Hough transform method, is proposed for measuring RBC velocity. The study indicated that the opticalflow method is suitable for accurately measuring the velocity of the RBCs in small or large micro-vessels.

© 2010 Elsevier Inc. All rights reserved.

Introduction

The relationship between bloodflow in microcirculation and the clinical physiology in blood circulation has been a wide-reaching and in-depth understanding. Various risk factors of diseases can be related to corresponding changes in microcirculation. For instance, Raynaud's syndrome(Wollersheim et al., 1988; Bertuglia et al., 1999), hyperten-sion(Bonacci et al., 1996; Cesarone, 2000) or diabetes(Chang et al., 1997; Tibiriçá et al., 2007) are usually accompanied with impaired microcirculation. Therefore, information in bloodflow of microcircu-lation plays an important role in health assessment and angiopathy prevention. Dynamic observation of microvascular mechanisms thus provides a deeper understanding of diseases and their relationship to the physiological function of microcirculation.

Quantization of the red blood cell (RBC) velocity in micro-vessels is a means of such observation. However, theflow measurement of RBC in micro vessels is still a challenge with current techniques. The flow in large vessels is able to be measured by using electro-magnetic blood flowmeter or ultrasonic Doppler flowmeter. Plenty useful information has been obtained on alterations in flow during physiological events and in the viscous properties of blood. A major

limitation of such measurements has been their inability to relate microvascular perfusion observed within individual micro-vessels to the topographical succession of arterioles, capillaries, and venules peculiar to a given tissue.

Image processing is an alternative, non-invasive approach to achieve this goal. Several literatures have been published in RBC velocity measurement in micro-vessels using dynamic video microscopy (Bollinger et al., 1974). The measurement of the displacement of relevant patterns (RBCs or plasma gaps) between two frames and the time separating them give an estimation of the RBC velocity. But it requires the selection of a good tracking pattern which appears to be difficult in larger vessels such as venules and arterioles. Several studies have focused on the use of cross correlations for the assessment of RBC velocity (Tsukada et al., 2000; Brox and Weickert, 2002). These methods can be divided into two categories: the temporal correlation and the spatial correlation methods. Umetani et al. (1989) have used image gradient method to measure microvascular red blood cell velocity and pointed out the time-varying relationship between the blood flow velocities. Recently, Opticalflow has been proposed as a quantitative method of measuring the detailed velocity distribution in micro-vessels (Sugii et al 2002, Tsukada et al., 2000). The authors have developed a particle image velocimetry (PIV) technique with improved dynamic range, spatial resolution and measurement accuracy, and also analyzed the blood velocity profile in microvessels of arterioles in rat mesentery (Sugii et al., 2002).Manjunatha and Singh (2002)also used opticalflow

⁎ Corresponding author. 91, Hsueh-Shih Road, Taichung, 404 Taiwan. Fax: +886 4 2205 4179.

E-mail address:tzungchi.huang@mail.cmu.edu.tw(T.-C. Huang). 0026-2862/$– see front matter © 2010 Elsevier Inc. All rights reserved. doi:10.1016/j.mvr.2010.07.007

Contents lists available atScienceDirect

Microvascular Research

(2)

method to measure velocity profiles of a blood flow in the multiple branching of frog mesentery employing microscopic video imaging (Manjunatha and Singh, 2002). In the literature byKempczynski and Grzegorzewski (2008), the Hough transform technique has been adopted to estimate the velocity of RBC aggregates during sedimenta-tion. RBC velocity was also estimated by using the Hough transform method in a simulation experiment. The results show that velocity assessment performs excellently up to 750 pixels/s. At higher velocities (N1250 pixels/s), the method fails and selects an alternative orientation that results in a large velocity error (Dobbe et al., 2008).

Generally, the bloodflow velocity inside microvessels in vivo is estimated along the central line of vessels. The accuracy of calculated results, which is algorithm dependant, has rarely been examined. In this paper, the red blood cell velocities in microvessels were calculated using the three mentioned measurement methods: cross correlation method, Hough transform method, and optical flow method, through simulation of intravital microscopic imaging. The accuracy of the methods was evaluated by applying these methods to simulated microvessel image sequences, of which the RBC velocities are known. The calculation accuracy of differentflow patterns and vessel shapes were also examined respectively.

Materials and methods Image generation

In microcirculation, the capillaries lie between, or connect, the arterioles and venules. Capillaries form extensive branching networks in a vivo body, which dramatically increase the surface areas available for rapid exchange of molecules. A capillary is a thin size form of vessel. Pre-capillary is a vessel lacking complete coats, located just to the arterial side of a capillary, and is about 3–5 times in diameter. It is not much different from capillary in other respects. Pre-capillary and capillary branch off from metarteriole and terminal arteriole. The simulation images were generated based on the physical (or physiological) and anatomical characteristics of microcirculation. The capillary bed is simulated in various forms, with one of them in straight line, and another clip shaped for one RBC to pass. Branching bed of pre-capillary into capillary is also simulated. A Matlab based computer program (MathWorks, version 7. 1) was used to generate the micro-vessel image sequences.

Blood is a complicate heterogeneous liquid with its viscosity varying with shear rate. It possesses non-Newtonian characteristics. Two kinds of dynamic bloodflow images were simulated in this study. One was to simulate the random motion of RBC in various shapes of blood vessels. Individual RBCs suspended in autologous plasma that have random motion were studied too in this category. The other one focused on the bloodflow variation with different RBC densities. This is included in our study because the density of RBC, or hematocrit, is the most important factor in blood hydrodynamic variation. The RBC density also dominates the variation in viscosity. The higher RBC density, or the higher hemotocrit, results in higher friction between the blood layers, which causes higher viscosity. Normal hematocrit is about 50% of blood in volume. In the simulation, the RBC densities were grouped to high, medium and low levels.

Vessel size and shapes

Vessel size varies in a wide range in human anatomy. Micro vessels were generated with various sizes: (1) 1-RBC wide in diameter (Fig. 1a), (2) 2-RBCs wide in diameter (Fig. 1b) and 4-RBCs wide in diameter (Fig. 1c). Different vessel shapes were generated with the Matlab-based program in order to cover various real conditions as bloodflow in micro-vessels. The RBC movement in vessels followed the velocity variation shown inFig. 1d through e.Fig. 1f and g gives 2 examples of shapes: branching and clip (or clip-shape). These shapes

can often be found in various parts of a human body. For example, the clip-shape vessel is very common infinger nail-fold.

Spatial distribution of RBC velocity in micro-vessel

The RBC velocity varies depending on the RBC location in a vessel. Mathematical expression of the RBC motion model is showing in

Fig. 2. The RBC velocity V was simulated as a function of radius r inside a vessel, V(r) = Vc(1−r2

/R2), in which Vc is the center velocity (r = 0), R is the vessel radius. Due to viscosity, the velocity is less in value as r increases (closer to the vessel wall). Motion in vessels of various RBC densities was also modeled. Low, medium and high density of RBC is defined based on the number of cells per unit volume.Fig. 3shows examples of vessels with different RBC densities. With different densities, the image sequences were generated with various maxi-mum RBC velocities of 1, 3, 5, and 10 pixels per frame respectively. The RBC velocities have a parabolic curve function in relation to the location inside a micro-vessel.

RBC velocity estimation Cross correlation method (CCM)

Several studies have focused on the use of cross correlations for the assessment of RBC velocity (Tsukada et al., 2000). The use of these methods corresponds to the tracking of characteristic patterns in space or in time. In this study, temporal correlation was used to measure the bloodflow velocity in the micro-vessels. For the temporal cross correlation methods, the transit time between two regions of the micro-vessel is estimated by measuring the intensity of two independent windows positioned on the skeleton of micro-vessel. This transit time, estimated using an image correlation function between the windows, is used to estimate the velocity.

Fig. 1. Various micro-vessels. Different sizes in diameter: (a)-(c) the diameter of the vessel is one, two and four times of the RBC size, respectively. (d)-(e) micro-vessel changes from narrow to wide and vice versa. (f)-(g) Two micro-vessel shapes: (f) branching (g) clip.

(3)

In particular correlation computation, the question resolves itself into the following three points. First, skeleton extraction is applied on the image to sketch the center line (i.e., skeleton) of the vessel which is also regarded as the bloodflow path in the capillary. The intensity of each skeleton pixel as in each section is determined from the images. Pixel intensity was averaged over the neighbor pixels within a 7-pixel wide square which is similar to the physical size of a RBC. Second, the

maximum value of the one demotion cross-correlation between the two sequential images was calculated to obtain the frame-to-frame RBC displacement and the velocity correspondingly. Considering two series x and y where window length i = 0, 1, 2...n, the correlation coefficient r is defined as

r = ffiffiffiffiffiffiffiffiffiffiffiffiffiSxy SxxSyy q = ∑n i = 1 xi− P x   × yi− P y   h i ffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi ∑n i = 1 xi− P x  2 ∑n i = 1 yi− P y  2 s ; −1≤ r ≤1 ð1Þ

where Px and y are the means of the corresponding series. Third, twoP windows with the same size were used in each site of vessel for cross-correlation computation. For two window cross-cross-correlation, the window length was equal to a half of segment length of each site. For example, one window was located in thefirst half of the arteriolar limb and the other window was in the second half. Furthermore, two maximum values were obtained from these windows in each site and were averaged to present the RBC displacement in two sequential frames.

Hough transform method (HTM)

The conventional Hough transform is a method for detecting straight lines (or curves) in images. It is basically a point-to-curve transformation that detects straight lines in images. In this study, pixel intensity of a profile image was extracted from pixels on the central line of a vessel. The intensity was averaged over the neighbor pixels within a 7-pixel wide square that is similar to the physical size of a RBC. Space-time diagram method is based on the profile image that is composed of pixel intensity on the central line of continuous frames. When the plasma gap and/or RBC in bloodflow are visible, the profiles of the space-time diagram will present clear slopes for velocity determination. The horizontal axis of the space-time diagram is vessel length (distance) and the vertical axis is frame number (time). The space-time diagram was divided into small square diagrams with a size of 16 × 16 pixels. Slopes were automatically estimated by using Hough transform. The RBC velocity was deter-mined by the slope of most apparently oblique line in all of the small space-time diagrams. In other words, Hough transform technique considers the polar representation of a line (Kempczynski and Grzegorzewski, 2008):

R = x cosθ + y sin θ ð2Þ

where (x, y) is the coordinate of each line pixel in the space–time diagram,θ the orientation of the vector normal to the line and starting

Fig. 2. The schema is to show that the RBC velocity V with the sameflow direction was simulated as a function of radius r inside a micro-vessel, V(r)=Vc(1-r2/R2), in which Vc is the

center velocity (r = 0), R is the micro-vessel radius. Due to viscosity, the velocity is less in value as r increases (closer to the vessel wall).

Fig. 3. An example of different RBC densities and simulated RBC velocities as functions of location in micro-vessel. In the left diagrams, low density (a), medium density (b), and high density (c) of RBCs are shown from top to bottom. The right diagram (d) indicates that RBCs in bloodflow have motion with a parabolic curve function in relation to the location inside a micro-vessel.

(4)

at the origin, and R the length of this vector, which is equal to the distance of the line to the origin. The discrete image of parameter space consists of accumulated cells, H(θ, R), that are incremented for each sinusoidal curve that passes the cell.

On a profile image, border detection is performed using the Canny edge method. Characteristic curves, straight lines in this study, are then detected using HTM. The angleθ is calculated using the straight lines. The bloodflow velocity V is calculated by equation

V = 1= tan θð Þ: ð3Þ

The horizontal axis of a profile image is the grey level distribution along the central line of a blood vessel. The spatial resolution of the image determined by hardware is 1.42μm, and if the temporal resolution is 1/30 s, determined by the maximum sampling rate of the system. From the velocity equation

V = △D = △T; ð4Þ

we know that the horizontal axis of a profile image corresponds to distance while the vertical corresponds to time. As the gaps between RBCs, or the variation among the RBCs, are reflected as the grey level variation along the central axis, the characteristic lines or strips can be obtained from the profile image. Using the angle between the lines and the horizontal axisθ, the velocity equation becomes

V = △D = △T = 1 = tan θð Þ ð5Þ

An example of using Hough Transform to get the angleθ from a blood flow profile image is given here. The Canny characteristic images are generated by applying Hough transform to the profile image which is shown as schema inFig. 4a. The resulted images are shown as (b) inFig. 4. The coordinates of the brightest spots are then

located, which are the maximum values of the transform. Since the point of the longest line appears many times at the same angle, by analyzing c to f inFig. 4, the maximum number of appearance and the corresponding angle are obtained for each image. Such brightest coordinates (R,θ) calculated for c, d, e and f are (23, −18°), (43, −19°), (40,−20°) and (26, −19°) respectively. The average blood flow velocity is thus 284.22μm/s.

Opticalflow method (OFM)

Opticalflow computation results in motion direction and motion velocity at image points. The immediate aim of OFM-based image analysis is to determine a motionfield. It reflects the image changes due to motion during a time interval dt, and the opticalflow field is the velocityfield that represents the three-dimensional motion of object points across a two-dimensional image. In the present study, this gradient-base OFM (Horn and Schunck, 1981; Wu et al., 2009; Huang et al., 2006; Zhang et al., 2008a; Guerrero et al., 2004; Zhang et al., 2008b) was applied to calculate the RBC velocity on two successive images. The velocity matrix of displacement, including horizontal and vertical movement respectively on the vessel image for each single pixel, was acquired using OFM. The velocity calculation equation in OFM is shown below.

vðn + 1Þ= vð Þn +∇f ∇f ⋅v n ð Þ+ ∂f ∂t α2+‖∇f ‖2 ! ð6Þ where n is iteration times and vð Þn is the average velocity derived from

the surrounding pixel.

Opticalflow equation calculates the difference of images and finds the deformed image to match the next frame. Originally, opticalflow method (OFM) requires a very small time interval between consecutive images and no significant change occurs between two

Fig. 4. (a) An image of temporal profile which was composed of intensity of pixels on the central line of micro-vessel. In this example, the length of central line is 256 pixels. (b) The edge of temporal profile (256×100 pixels) was obtained by using Canny edge detection, which was divided into four of small square diagrams with a size of 64×100 pixels from top to bottom. (c)-(f) are the Hough transformations which correspond to Canny edge detection as in (b). The angle of the maximal aggregate value of appearance for each image is (c) -18°, (d) -19°,(e) -20°and (f) -19° respectively.

(5)

consecutive images. The original OFM developed by Horn and Schunck was not reliable in velocity calculations when object motion is significant between two consecutive frames, in which no features are overlapping.

To overcome this problem, optical flow calculations are repro-cessed for a number of times with continuously updated deformed images, which converges the velocityfield to accurately match the final deformation to the target image. With this implementation in the OFM, large motions can be accurately calculated and the quality of registration is significantly improved, regardless of the motion size. Results and discussion

The velocities calculated using CCM, HTM and OFM, respectively, were compared to each other and with the known values from the simulations by the Matlab based program. This comparison was applied to various RBC densities, velocities, shapes, vessel sizes and size variations. In order to evaluate the performances of the proposed algorithms, a simulated experiment with random RBCs motion is used at first. The mean and standard deviation of differences among the calculated values in number of pixels by using the three image

processing methods were listed in Table 1, which shows overall average errors of the velocity estimation in various micro-vessel cases. For the velocity estimation in various micro-vessel beds, OFM gave the minimum value in average error while CCM yielded the maximum.

According to calculations using the window diameter of 30~40 pixels for CCM, the flow velocity of the centre micro-vessel were within 2.741 ± 5.925 pixels/frame. The window size is equal to the size of sensors for CCM. The image intensity of an RBC in micro-vessels was similar to each other. This could cause uniform signal in the window, which in turn decreases accuracy significantly. For HTM, the mage of temporal profile was previously intensified by the Canny edge detection to avoid this problem. Consequently, the calculations using OFM and HTM show better agreement with known values for higher densities. The standard deviations for HTM and OFM are about 1 pixels/frame. Judging from the above, the results indicate that the OFM is a suitable image processing option.

The attention was thus focused on the evaluation of OFM in our further studies with various vessel shapes. The data analysis points were selected as shown inFig. 5.Fig. 6a through d shows the OFM estimations of the random RBC velocities of various vessel shapes and compares them with the known values from the simulated images. The typical difference between the OFM estimations and known velocities were less than 2 pixels/frame for various micro-vessel beds. Another experiment, which simulates theflow of RBCs in a straight line in micro-vessel with a single arteriole (diameter: 33 pixels), was generated with 50 frames. Both CCM and HTM failed and resulted with an alternative orientation and large velocity errors. Therefore, the two methods were not able to measure velocities in a larger micro-vessel, which left OFM the only choice for such cases.

The calculated velocities using OFM are compared with the known values inTable 2 and Table 3for different RBC densities. With higher density of RBCs, more detailed structures help improving pixel-to-pixel correspondence between the images in sequence, thus better accuracy can be achieved in OFM calculations. For the low density cases, the relatively larger areas of non-cell regions in the images weaken the correspondence, which introduces larger errors in optical flow calculations. As shown in diagram a ofFig. 7, the average velocity error is less than 0.3 pixels/frame for all densities studied with

Table 1

The velocity estimation in various micro-vessel cases by using three measurement methods. The vessel shape labeling is the same as it inFig. 1.

The average error for different image processing methods, Mean± S.D. (pixel/frame) Measurement

Microvessel method shape pattern Cross-correlation Hough transform Opticalflow (a) 2.693 ± 5.628 1.872 ± 0.798 0.718 ± 1.158 (b) 2.705 ± 5.619 1.958 ± 1.029 1.053 ± 1.166 (c) 2.721 ± 5.653 1.877 ± 0.986 1.115 ± 1.188 (d) 2.716 ± 5.822 2.011 ± 0.975 1.275 ± 1.166 (e) 2.704 ± 5.7107 2.043 ± 1.0931 1.070 ± 1.162 (f) 2.362 ± 4.323 2.040 ± 1.026 1.220 ± 1.171 (g) 3.288 ± 8.116 2.350 ± 0.925 1.155 ± 1.180

The overall average error of RBC displacement

2.741 ± 5.925 2.022 ± 1.001 1.087 ± 1.173

(6)

maximal velocity of 1, 3, and 5 pixels, respectively. The worst relative error occurred at the highest maximum velocity case (10 pixels/ frame), while the worst relative average error was at the lowest maximum velocity case (1 pixel/frame). The relative average error can be as high as 25% (Fig. 7b).

Conclusions

Three methods, which are commonly applied in red blood cell (RBC) velocity measurement in micro-vessels, were evaluated with

simulated microscopic video image sequences in this study. The opticalflow method (OFM) demonstrated superior accuracy over the cross-correlation method (CCM) and Hough transform method (HTM). With larger size vessels, for which both CCM and HTM have difficulties in RBC velocity estimation, OFM can still provide accurate results. This comparison study concluded that OFM is suitable for

Fig. 6. The velocity analysis using OFM in micro-vessels at selected points.

Table 2

The absolute average error by suing OFM in different RBC densities with the same micro-vessel bed.

The average error estimation of RBC velocity, Mean ± S.D. (pixel/frame) RBC movement, maximum (average)

Velocity 1 pixel 3 pixels 5 pixels 10 pixels

Density (0.7) (2.1) (3.5) (7) Low 0.200 ± 0.157 0.220 ± 0.176 0.267 ± 0.171 2.107 ± 0.776 Medium 0.203 ± 0.159 0.235 ± 0.171 0.268 ± 0.168 1.440 ± 0.578 High 0.204 ± 0.172 0.246 ± 0.175 0.281 ± 0.177 0.911 ± 0.473 Overall 0.202 ± 0.163 0.234 ± 0.174 0.272 ± 0.172 1.486 ± 0.609 Table 3

The relative average errors by suing OFM in different RBC densities with the same micro-vessel bed.

The percentage of average error in different RBCs velocity (%) Maximal velocity

Velocity 1 pixel 3 pixels 5 pixels 10 pixels

Density

Low 28.6 10.5 7.6 30.1

Medium 29.0 11.2 7.7 20.6

High 29.1 11.7 8.0 13.0

Overall Mean ± S.D. 28.9 ± 0.3 11.1 ± 0.6 7.8 ± 0.2 21.2 ± 8.6

(C.V.) (0.9) (5.4) (2.7) (40.3) Fig. 7. The velocity estimation in various RBCs densities within same micro-vessel: (a)

absolute average errors, (b) relative average errors. T.-C. Huang et al. / Microvascular Research 80 (2010) 477–483

(7)

accurate measurement of the RBC velocity in small or large micro-vessels.

In the future work, OFM will be applied to estimate the bloodflow velocity in micro-vessels in vivo laboratory animals to analyze the change of bloodflow velocity on the surface of tumor as tumor grows. Acknowledgment

This study wasfinancially supported by the school project of China Medical University, Taiwan (CMU-98-C-10).

References

Bertuglia, S., Leger, P., Colantuoni, A., Coppini, G., Bendayan, P., Boccalon, H., 1999. Differentflowmotion patterns inhealthy controls and patients with Raynaud's phenomenon Technol. Health Care 7, 113–123.

Bollinger, A., Butti, P., Barras, J.P., Trachsler, H., Siegenthaler, W., 1974. Red blood cell velocity in nailfold capillaries of man measured by a television microscopy technique. Microvasc. Res. 7, 62–72.

Bonacci, E., Santacroce, N., D'Amico, N., Mattace, R., 1996. Nail-fold capillaroscopy in the study of microcirculation in elderly hypertensive patients. Arch. Gerontol. Geriatr. suppl. 5, 79–83.

Brox, T., Weickert, J., 2002. Nonlinear matrix diffusion for opticflow estimation 24th DAGM Symp: Springer LNCS, vol. 2449, pp. 446–453.

Cesarone, M.R., Incandela, L., Ledda, A., De Sanctis, M.T., Steigerwalt, R., Pellegrini, L., Bucci, M., Belcaro, G., Ciccarelli, R., 2000. Pressure and microcirculatory effects of treatment with lercanidipine in hypertensive patients and invascular patients with hypertension. Angiology 51, 53–63.

Chang, Chung-Hsing, Tsai, Rong-Kung, Wu, Wen-Chuan, Kuo, Song-Ling, Yu, Hsin-Su, 1997. Use of dynamic capillaroscopy for studying cutaneous microcirculation in patients with diabetes mellitus. Microvasc. Res. 53, 121–127.

Dobbe, J.G.G., Streekstra, G.J., Atasever, B., van Zijderveld, R., Ince, C., 2008. Measurement of functional microcirculatory geometry and velocity distributions using automated image analysis. Med. Biol. Eng. Comput. 46, 659–670. Guerrero, T., Zhang, G., Huang, T.-C., et al., 2004. Intrathoracic tumour motion

estimation from CT imaging using the 3D opticalflow method. Phys. Med. Biol. 49, 4147–4161.

Horn, B.K.P., Schunck, B.G., 1981. Determining opticalflow. Artif. Intell. 17, 185–203. Huang, T., Zhang, G., Guerrero, T., et al., 2006. Semi-automated CT segmentation using

opticflow and Fourier interpolation techniques. Comput. Methods Progr. Biomed. 84, 124–134.

Kempczynski, A., Grzegorzewski, B., 2008. Estimation of red blood cell aggregate velocity during sedimentation using the Hough transform. Opt. Commun. 281, 5487–5491.

Manjunatha, M., Singh, M., 2002. Computerised visualisation from images of bloodflow through frog mesenteric microvessels with multiple complexities. Med. Biol. Eng. Comput. 40, 634–640.

Sugii, Y., Nishio, S., Okamoto, K., 2002. In vivo PIV measurement of red blood cell velocity field in microvessels considering mesentery motion. Physiol. Meas. 23 (2), 403–416. Tibiriçá, E., Rodrigues, E., Cobas, R.A., Gomes, M.B., 2007. Endothelial function in patients with type 1 diabetes evaluated by skin capillary recruitment. Microvasc. Res. 73, 107–112.

Tsukada, K., Minamitani, H., Sekizuka, E., Oshio, C., 2000. Image correlation method for measuring bloodflow velocity in microcirculation: correlation ‘window’ simulation and in vivo image analysis. Physiological Measurement 21 (4), 459–471. Wollersheim, H., Reyenga, J., Thien, T., 1988. Laser Doppler velocimetry offingertips

during heat provocation in normals and in patients with Raynaud's phenomenon Scand. J. Clin. Lab. Invest. 48, 91–95.

Wu, Chih-Chieh, Zhang, Geoffrey, Huangc, Tzung-Chi, Lin, Kang-Ping, 2009. Red blood cell velocity measurements of complete capillary infinger nail-fold using optical flow estimation. Microvasc. Res. 78, 63–68.

Zhang, G., Huang, T.-C., Forster, K., et al., 2008a. Dose mapping: validation in 4D dosimetry with measurements and application in radiotherapy follow-up evalu-ation. Comput. Methods Progr. Biomed. 90, 25–37.

Zhang, G., Huang, T.-C., Guerrero, T., et al., 2008b. Use of three-dimensional (3D) optical flow method in mapping 3D anatomic structure and tumor contours across four-dimensional computed tomography data. J. Appl. Clin. Med. Phys. 9, 59–69.

數據

Fig. 1. Various micro-vessels. Different sizes in diameter: (a)-(c) the diameter of the vessel is one, two and four times of the RBC size, respectively
Fig. 3. An example of different RBC densities and simulated RBC velocities as functions of location in micro-vessel
Fig. 4. (a) An image of temporal profile which was composed of intensity of pixels on the central line of micro-vessel
Fig. 5. The measurement position in various cases of micro-vessel bed.

參考文獻

相關文件

The first row shows the eyespot with white inner ring, black middle ring, and yellow outer ring in Bicyclus anynana.. The second row provides the eyespot with black inner ring

In this paper, we propose a practical numerical method based on the LSM and the truncated SVD to reconstruct the support of the inhomogeneity in the acoustic equation with

“Find sufficiently accurate starting approximate solution by using Steepest Descent method” + ”Compute convergent solution by using Newton-based methods”. The method of

In this paper, we build a new class of neural networks based on the smoothing method for NCP introduced by Haddou and Maheux [18] using some family F of smoothing functions.

Optim. Humes, The symmetric eigenvalue complementarity problem, Math. Rohn, An algorithm for solving the absolute value equation, Eletron. Seeger and Torki, On eigenvalues induced by

In the method, caching data are kept in three different version sets – current version set, new version set and invalid version set.. Further, we analyze the performance

In this paper, the study area economic-base analysis and Location Quotient method of conducting description, followed by division of Changhua County, Nantou County,

The main goal of this research is to identify the characteristics of hyperkalemia ECG by studying the effects of potassium concentrations in blood on the