• 沒有找到結果。

Stability-indicating High-Performance Liquid Chromatographic Assay Method and Photostability of Carprofen

N/A
N/A
Protected

Academic year: 2021

Share "Stability-indicating High-Performance Liquid Chromatographic Assay Method and Photostability of Carprofen"

Copied!
1
0
0

加載中.... (立即查看全文)

全文

(1)

Stability-indicating High-Performance Liquid

Chromatographic Assay Method and Photostability of

Carprofen

吳安邦

Wu AB;Chen CY;Chu SD;Tsai YC and Chen FA*

Abstract

A rapid, sensitive, and accurate stability-indicating high-performance liquid chromatographic assay method for determining the degradation of carprofen (CPF) is developed and validated under acidic, basic, or photo-irradiated conditions. The analysis is monitored with a Cosmosil 5C18-AR column using a mobile phase of CH3CN-H2O-AcOH (50:49:1, v/v/v) at 260 nm. The developed method satisfies the system suitability criteria, peak integrity, and resolution among the parent drug and its degradation products. The results indicate that the established assay method shows good selectivity and specificity suitable for stability measurements of CPF. CPF is found to be more sensitive to exposure to light and in acidic conditions, but it is stable in a basic medium. The kinetic study of the photodegradation of CPF follows an apparent first-order reaction in a variety of solvents. The solvent effects on the rates of degradation are in the decreasing order of chloroform > dichloromethane > methanol > ethanol > 2-propanol, which is irrelevant to the dielectric constant epsilon. However, the hydrogen-donating ability of the solvents is essential to the photochemical decomposition of CPF. A plot of log k versus the Kirkwood function exhibits a linear relationship in aqueous ethanolic solutions, which implies that degradation proceeds via an ionic mechanism.

參考文獻

相關文件

3: Calculated ratio of dynamic structure factor S(k, ω) to static structure factor S(k) for "-Ge at T = 1250K for several values of k, plotted as a function of ω, calculated

The superlinear convergence of Broyden’s method for Example 1 is demonstrated in the following table, and the computed solutions are less accurate than those computed by

The Model-Driven Simulation (MDS) derives performance information based on the application model by analyzing the data flow, working set, cache utilization, work- load, degree

/** Class invariant: A Person always has a date of birth, and if the Person has a date of death, then the date of death is equal to or later than the date of birth. To be

Biases in Pricing Continuously Monitored Options with Monte Carlo (continued).. • If all of the sampled prices are below the barrier, this sample path pays max(S(t n ) −

This study aimed to establish the strength models of High-Performance Concrete (HPC) using Nonlinear Regression Analysis (NLRA), Back-Propagation Networks (BPN) and

Shukha, R., and Baker, R., (2003), “Mesh Geometry Effects on Slope Stability Calculation by FLAC Strength Reduction Method – Linear and Non-linear Failure Criteria”, FLAC

explore the effect of the different analysis method on the determination of the safety factor for slope stability under stormy