• 沒有找到結果。

SpectraMax i3x Multi-Mode Detection Platform

N/A
N/A
Protected

Academic year: 2022

Share "SpectraMax i3x Multi-Mode Detection Platform"

Copied!
30
0
0

加載中.... (立即查看全文)

全文

(1)

SpectraMax i3x Multi-Mode

Detection Platform

產品經理 楊博甦 Hant Yang

金萬林企業股份有限公司

(2)
(3)

• Research

 Microplate reader

 Washer

 Genepix

• Drug Screening

 FLIPR

 Flexstation 3

 ImageXpress

 Ionworks Quattro

About MD products

3

(4)

MD microplate reader—The TOP1 !!

第一台可以動力學偵測 第一台連續光譜光度儀 第一台可以Pathcheck®

第一台多功能光度儀

(5)

Imagine a Multi-Mode Plate Reader that evolves over time

3 Mode Base Functionality

Extended Dynamic Range

MiniMax™ Imaging Cytometer option

Improved sensitivity with Spectral Fusion™ Illumination

Ease of Use of SoftMax®

Pro Software

Flexibility of User- Upgradeable Application

Cartridges

(6)

Cartridges – Future Ready

• User-upgradeable within 2 minutes

– No messy upgrades

– No instrument down time – Only cost – new cartridge

• Applications (18 options)

– ScanLaterTM (Western Blot) – AlphaScreen® (PE)

– HTRF® (Cisbio) – Customization – And more

(7)

Each Cartridge Is One Microplate Reader

• Detection Cartridges include:

• Optimal Light Source

– AlphaScreen®: laser diode – FL: LED

• Detection Specific Electronics

• Label Specific Optics

– Excitiation filter (s) – Emission filter (s) – Dichroics

– Polarizer(s) for FP

(8)

Detection Cartridge Options – How they work

LED,

Flash lamp, or Laser diode

Reference Diode

Sample

Channel 1 Channel 2

(9)

HTRF with I3x

Reader EC50* Z’ factor Window (Ratio)

Window (%Delta F) SpectraMax i3 19.3

nM

0.91 8747 3024

* Optimal setting for i3 as determined with Cisbio Certification are 30 µs delay, 400 µs integration, 30 pulses

HTRF cAMP HiRange assay – standard curve Cisbio

requirements

Passing value

i3x

Signal/bkg ≥ 40 106.8

DF% High ≥ 600 939.3

DF% Low ≥ 15 24.4

CV Std 0 < 10 3.8

(10)

ScanLater

TM

Western Blot Detection

• First western blot detection on a multi- mode microplate reader

• Time-resolved fluorescence (TRF) based assay

Eu 2nd antibody

Scan now or up to 30 days later

• Cost saving

Less expensive than buying an gel imager

• Quantitation

High sensitivity for fg concentrations

• Time-saving protocols

Eliminate substrate, darkroom, or exposure time requirements

Fluorescence Intensity

Background Fluorescence

1-Excitation

3-Emission Signals

(Europium labeled)

2

Fluorescence intensity emission measurement

(11)

ScanLater

TM

Advantages Over Other Methods

E U

Flash lamp

Image or use film

Chemiluminescence Fluorescence Intensity TRF

Sensitivity fg pg fg/pg

Dynamic Range 1-2 logs 4 logs 4 logs

Substrate Yes Not needed Not Needed

Stability Hours Weeks Months

Quantitative Semi/indirect measurement Quantitative/direct measurement Quantitative/direct measurement

Output Film/Imaging Imaging Imaging

(12)

Absorbance with SpectraMax i3 Platform

• Light source: Xenon Flash Lamp

• Detection: Photodiode

• Wavelength selection: Dual Monochromator

• Spectral Range: 230-1000 nm

• Read: top to bottom

• Bandwidth: 4nm

• Performance

• System has less stray light than single Monochromator system

More sensitive

Linearity up to 4OD

Absorbance scan of Holmium oxide; 300-600nm in 1nm increments

(13)

Micro-Volume DNA/RNA Quantitation

SpectraDrop Micro-Volume Microplate

• SBS format holder + 2 slide design

• 24 or 64 spot microplate

• 2uL or 4uL configurations

• Sensitivity

• 2ng/uL (dsDNA)

• Easy to clean

• Replaceable slide design

LLD < 2 ng/uL

DNA standards ranged from 50 ng/µL down to 2.4 ng/µL

(14)

Fluorescence with SpectraMax i3 Platform

• Light source: Spectral Fusion™ Illumination

• Detection: PMT

• Wavelength selection: 2x2 Monochromator Design

• Spectral Range: 250-850 nm

• Read: top and bottom

Top read no fibers for Ex and Em

Bottom: fibers for the Ex and Em

• Bandwidth: Ex 9 or 15 nm, Em 15 or 25 nm

• Performance

2x2 Monochromator design in combination with Spectral Fusion™ Illumination allow this system to be

More sensitive

Higher dynamic range Full spectral range

Fluorophore i3 LLD Coumarin 200pM Alexa 430 20pM Fluorescein 1pM Rhodamine 5pM Texas Red 10pM Alexa 633 5pM Alexa 647 3pM Alexa 700 10pM

384 Top, Optimized LLD results

(15)

Unique Spectral Fusion

TM

Illumination

• Revolutionary light source design

Xenon flash lamp (for deep UV) – Intensified by LEDs in visible range – More powerful

• Increased sensitivity

– Ultimately increasing the sensitivity of the system across the full spectrum

• Auto LED

• High dynamic range for all conc. on one plate

No need to reread No saturation

230 nm 1000 nm

Xenon flash lamp

(16)

Em

Ex

• Advantage:

• Dual monochromators for excitation and/or emission provide best stray light elimination

• Limitation

• Loss of excitation and emission signal (poor light efficiency) can lead to decreased sensitivity

• Solution for I3:

• Better light source with Spectral Fusion Illumination overcomes the efficiency limitations of 2x2 Monochromator Design

• More sensitive than other 2x2 Monochromator Design system

Wavelength Selection: 2x2 Monochromator Design

(17)

Extended Dynamic Range

SpectraMax i3 Base System

Est. dyn. range (decades)

Alexa 430 > 4

Fluorescein > 6

Alexa 700 > 5

Fluorescein Dynamic range (decades):

~6.7

Alexa Fluor 700 Dynamic range (decades):

~5.2

(18)

Luminescence with SpectraMax i3 system

• Detection: Cooled PMT

• Wavelength selection: Dual Monochromator for Em only

• Spectral Range: 300-850 nm

• Read: top only

• Bandwidth for Em: 15 or 25 nm

• Performance:

Low instrument background

High sensitivity across the visible range (most applications)

Firefly luciferase standard curve ranged from 10 µg/mL down to 1 pg/mL

Dynamic range (decades): ~7

ATP standards ranged from 100 µg down to 10 pg Dynamic range ~7 decades

(19)

Luminescence with SpectraMax i3 system

• In SoftMax pro two options for Emission:

1. Read at all wavelengths

2. Read at specific wavelengths (BRET)

a) Choose the BW

b) Choose up to 4 different wavelengths

c) Choose the Wavelength

(20)

SoftMax Pro Powerful Data Analysis

• Extensive Data Analysis Features

• 3D data visualization

• 19 Curve Fit options

• Plate Cloning feature

• Custom formula writing

• Customizable protocol editing

• Now with image analysis features

• Relevant Help information 1

click away

(21)

The SpectraMax® MiniMax Imaging Cytometer

• A field upgradeable option for the SpectraMax i3 system

• Adds imaging capabilities to the plate reader

• Images in bright-field/transmitted light and fluorescence

• Add functionality for:

• Quick check of your cells

• Cellular resolution assays

“When is the last time you actually looked at your

cells?”

(22)

What advantage does MiniMax offer?

Total intensity

MiniMax

“sees” cells

The Plate reader detector

“sees” RFUs

236 Cells 10 Cells 0 Cells

105.7 RFU 47.7 RFU 45.0 RFU

Easily see your low cell concentration, where in plate reader data might be in the noise

(23)

SpectraMax® MiniMax™ 300 Imaging Cytometer

• Combine cellular imaging and microplate assays

• StainFree™ Technology

– Eliminate staining and maintain cell viability – Cell count

– Confluency

• Multi-channel

– Transmitted, green, red channels

– Toxicity assays

• SoftMax® Pro Software

– Powered by MetaMorph®

– Acquire and analyze

(24)

SoftMax® Pro Software for Imaging Analysis

• Visualization

– Well-by-well data or cell-by-cell data

• Diverse analysis types

(25)

Cell Analysis in SoftMax Pro Software

• Cell Count

• Analysis separates and counts cells based on intensity over background and cell size

• Cell Proliferation/Toxicity

• Analysis detects cell coverage in the well- total cell area

• Marker Expression

• Analysis determines level of signal intensity corresponding to protein or marker expression

Other output parameters can be also

measured

(26)

MiniMax Hardware Details

• Single 4X Objective (Nikon PLAN Fluor)

Proprietary solid state illumination

• Fixed dichroic and filters

Green 541/108 nm Red 713/123 nm

• High sensitivity CCD camera (1.25Mpix, 12-bit)

Custom laser autofocus

• Transmitted Light/Bright-field illumination

(27)

ELISA

SNP genotyping Molecular beacons

ATP assay

Wellular Resolution

MiniMax Bridging the gap between plate readers and HCS

Large Format Intracellular Detail Micronuclei Neurite Outgrowth Intracellular Trafficking

Cellular Resolution

Cell viability GFP assays FRET assays

IMAP

Cell Counting Cell Migration Whole organism

Live - Dead Cell Cycle Mitotic index

Single Data Point

Sub-Wellular Resolution Sub-Cellular Resolution

Plate Reader MinMax

Imaging Cytometer HCS Instrument

(28)

服務團隊陣容

金萬林企業股份有限公司 產品技術應用服務

• 鄒志成 博士 MD產品服務時間二年

• 楊博甦 碩士 MD產品服務時間五年

• 杜宜 碩士 MD產品服務時間三年

• 侯沛庠 碩士 MD產品服務時間一年

• 王舒惠 碩士 MD產品服務時間一年 維修工程師

• 王佑毓 MD產品維修年資七年

• 陳建因 MD產品維修年資三年 Molecular Devices台灣分公司

資深產品應用專員 維修工程師

• Samantha Lee . Jim Chou

28

Your success is our success

(29)

G

(30)

Thank you for your attention!

Any Question?

http://www.kimforest.com

http://www.moleculardevices.com Hant@kimforest.com

產品經理 楊博甦 Hant Yang 服務電話:0980-580-155 金萬林企業股份有限公司 免付費:0800009695

參考文獻

相關文件

The design of a sequential circuit with flip-flops other than the D type flip-flop is complicated by the fact that the input equations for the circuit must be derived indirectly

engineering design, product design, industrial design, ceramic design, decorative design, graphic design, illustration design, information design, typographic design,

A multi-objective genetic algorithm is proposed to solve 3D differentiated WSN deployment problems with the objectives of the coverage of sensors, satisfaction of detection

Abstract—We propose a multi-segment approximation method to design a CMOS current-mode hyperbolic tangent sigmoid function with high accuracy and wide input dynamic range.. The

In this thesis, we develop a multiple-level fault injection tool and verification flow in SystemC design platform.. The user can set the parameters of the fault injection

Results indicate that the proposed scheme reduces the development cost, numbers of design change, and project schedule of the products, and consequently improve the efficiency of

In the second phase, the optimization design of the dot pattern of the light guide plate can be launched to categorize the light guide plate into 31 areas and used the

When applying the detection software and algorithm to color printing, there are the situation like change of source of light, offset of printing and rolling processing