• 沒有找到結果。

A Wirelessly Powered Smart Contact Lens with Reconfigurable Wide Range and Tunable Sensitivity Sensor Readout Circuitry

N/A
N/A
Protected

Academic year: 2021

Share "A Wirelessly Powered Smart Contact Lens with Reconfigurable Wide Range and Tunable Sensitivity Sensor Readout Circuitry"

Copied!
12
0
0

加載中.... (立即查看全文)

全文

(1)

sensors

Article

A Wirelessly Powered Smart Contact Lens with

Reconfigurable Wide Range and Tunable

Sensitivity Sensor Readout Circuitry

Jin-Chern Chiou1,2, Shun-Hsi Hsu1,*, Yu-Chieh Huang2, Guan-Ting Yeh2, Wei-Ting Liou2and Cheng-Kai Kuei2

1 Department of Electrical and Computer Engineering, National Chiao-Tung University, Room 617, Engineering Building 5, No. 1001, Ta Hsueh Rd., Hsinchu 30010, Taiwan; chiou@mail.nctu.edu.tw

2 Institute of Electrical Control Engineering, National Chiao-Tung University, Room 617, Engineering Building 5, No. 1001, Ta Hsueh Rd., Hsinchu 30010, Taiwan; yuchieh.ece99g@g2.nctu.edu.tw (Y.-C.H.);

x210469@nctu.edu.tw (G.-T.Y.); steven61617@yahoo.com.tw (W.-T.L.); gloooomylife@gmail.com (C.-K.K.) * Correspondence: shhsu.eed01g@g2.nctu.edu.tw; Tel.: +886-3-571-2121 (ext. 54437)

Academic Editors: Pak Kwong Chan and Holden King-Ho Li

Received: 14 November 2016; Accepted: 30 December 2016; Published: 7 January 2017

Abstract: This study presented a wireless smart contact lens system that was composed of a reconfigurable capacitive sensor interface circuitry and wirelessly powered radio-frequency identification (RFID) addressable system for sensor control and data communication. In order to improve compliance and reduce user discomfort, a capacitive sensor was embedded on a soft contact lens of 200 µm thickness using commercially available bio-compatible lens material and a standard manufacturing process. The results indicated that the reconfigurable sensor interface achieved sensitivity and baseline tuning up to 120 pF while consuming only 110 µW power. The range and sensitivity tuning of the readout circuitry ensured a reliable operation with respect to sensor fabrication variations and independent calibration of the sensor baseline for individuals. The on-chip voltage scaling allowed the further extension of the detection range and prevented the implementation of large on-chip elements. The on-lens system enabled the detection of capacitive variation caused by pressure changes in the range of 2.25 to 30 mmHg and hydration level variation from a distance of 1 cm using incident power from an RFID reader at 26.5 dBm.

Keywords:capacitance-to-digital converter (CDC); capacitive sensor; soft contact lens; UHF RFID Class1 Gen2

1. Introduction

An increase in on-lens sensors presents an attractive proposition to maximize the procurement of eye health information to the maximum possible extent. The geometry and size constraints of a contact lens necessitate components that are miniature and compact to fit in the lens. Hence, a wirelessly powered smart contact lens (SCL) system with a reconfigurable capacitance-to-digital converter (CDC) was proposed in this study. The proposed soft contact lens was fabricated with hydroxyethyl methacrylate (HEMA) hydrogel and a commercial manufacturing process to improve edge configuration, compliance, and comfort [1]. Intraocular pressure (IOP) measurement for glaucoma prevention was used to illustrate the functionality of the proposed SCL system in the study.

Continuous IOP monitoring in glaucoma patients with high accuracy and high reliability is constantly required to enable prompt detection and daily tracking [2]. Methods were proposed for continuous and long-term IOP monitoring by using an implant pressure sensor [3–5] and eye curvature monitoring [6]. Pressure sensor implants are invasive and require surgery, thereby reducing patient compliance. Additionally, the implants usually require high incident wireless power to operate the

(2)

Sensors 2017, 17, 108 2 of 12

devices, and this could cause a rise in the temperature of eye tissues. In contrast, the on-lens eye curvature method is less invasive and can provide direct access to the eye surface with minimal disturbances. However, the sensors are typically fabricated on hard silicone or plastic materials [6], and thus lead to discomfort in terms of long-term wear.

Previous studies demonstrated a microelectromechanical system (MEMS) capacitive pressure sensor on a contact lens [7,8] and sensor chips [9,10] for long-term IOP monitoring. An extant study demonstrated the wireless harvesting of smart contact lens and antenna design [10]. This study involved proposing a reconfigurable CDC to improve the capacitance detection characteristics and demonstrated the functionalities of a wirelessly powered SCL system. The results indicated improvements in the capacitance detection range and sensitivity when compared with those of the CDC as reported in previous studies [9,10]. The rest of the paper is organized as follows: Section2

describes published research that includes studies examining system design, antennae, sensor chips, and capacitive sensors; Section3describes the improved sensor readout circuitry and contact lens assembly process; Section4discusses the results of experimental investigations of the wirelessly operated SCL system. Finally, conclusions and discussions are presented in Section5.

2. Related Work

This section briefly summarizes extant research including system design, antennae, sensor chips, and capacitive sensors.

2.1. System and Sensor Chip Design

A previous study [9] presented an integrated wireless SCL system as shown in Figure1a,b. The SCL system included a capacitive sensor for eye healthcare monitoring, a silicon chip with readout circuitry and an ultra-high frequency (UHF) radio-frequency identification (RFID) Gen-2 wireless transceiver, and a small loop antenna. The SCL system communicated with an on-glass RFID reader for sensing data collection and sensor control.

Sensors 2017, 17, 108 2 of 12

reducing patient compliance. Additionally, the implants usually require high incident wireless power to operate the devices, and this could cause a rise in the temperature of eye tissues. In contrast, the on-lens eye curvature method is less invasive and can provide direct access to the eye surface with minimal disturbances. However, the sensors are typically fabricated on hard silicone or plastic materials [6], and thus lead to discomfort in terms of long-term wear.

Previous studies demonstrated a microelectromechanical system (MEMS) capacitive pressure sensor on a contact lens [7,8] and sensor chips [9,10] for long-term IOP monitoring. An extant study demonstrated the wireless harvesting of smart contact lens and antenna design [10]. This study involved proposing a reconfigurable CDC to improve the capacitance detection characteristics and demonstrated the functionalities of a wirelessly powered SCL system. The results indicated improvements in the capacitance detection range and sensitivity when compared with those of the CDC as reported in previous studies [9,10]. The rest of the paper is organized as follows: Section 2 describes published research that includes studies examining system design, antennae, sensor chips, and capacitive sensors; Section 3 describes the improved sensor readout circuitry and contact lens assembly process; Section 4 discusses the results of experimental investigations of the wirelessly operated SCL system. Finally, conclusions and discussions are presented in Section 5.

2. Related Work

This section briefly summarizes extant research including system design, antennae, sensor chips, and capacitive sensors.

2.1. System and Sensor Chip Design

A previous study [9] presented an integrated wireless SCL system as shown in Figure 1a,b. The SCL system included a capacitive sensor for eye healthcare monitoring, a silicon chip with readout circuitry and an ultra-high frequency (UHF) radio-frequency identification (RFID) Gen-2 wireless transceiver, and a small loop antenna. The SCL system communicated with an on-glass RFID reader for sensing data collection and sensor control.

RX Antenna Sensor

Chip Sensor

Smart Contact Lens

SCL Readout System Power

Signal Command Data RFID Reader Components TX antenna Rectifier COMP

Envelop Detector Demodulator

DOUT CMOD Modulator L im it er Bandgap Bias Regulator Digital Processor Power-On Reset OSC Sensor Readout Circuitry Capacitive Sensor Tag Antenna

Wirelessly Powered Smart Contact Lens

Sensor IC

RFID Front End

(a) (b)

Figure 1. (a) Proposed smart contact lens (SCL) system architecture; (b) Block diagram of the proposed smart contact lens.

Figure 1b shows the architecture of a proposed sensor chip. The sensor chip includes the analog front-end circuits for power scavenging and data demodulation, a digital processor for protocol format generation and sensing information processing, and a sensor readout circuitry to acquire the sensor information. A capacitive sensor was employed in the design to detect eye curvature changes due to IOP deviations. The measured capacitance value was converted to a bit-stream format for further digital processing. Size constraints on the lens led to low antenna efficiency and low energy storage capability and limited the available power on the lens. Therefore, low power electronics design and efficient power management were crucial in the proposed system. Furthermore, separated regulators were used in the design to avoid noise coupling between digital and analog

Figure 1.(a) Proposed smart contact lens (SCL) system architecture; (b) Block diagram of the proposed smart contact lens.

Figure1b shows the architecture of a proposed sensor chip. The sensor chip includes the analog front-end circuits for power scavenging and data demodulation, a digital processor for protocol format generation and sensing information processing, and a sensor readout circuitry to acquire the sensor information. A capacitive sensor was employed in the design to detect eye curvature changes due to IOP deviations. The measured capacitance value was converted to a bit-stream format for further digital processing. Size constraints on the lens led to low antenna efficiency and low energy storage capability and limited the available power on the lens. Therefore, low power electronics design and

(3)

Sensors 2017, 17, 108 3 of 12

efficient power management were crucial in the proposed system. Furthermore, separated regulators were used in the design to avoid noise coupling between digital and analog circuits, that is, the analog supply voltage for sensitive sensor readout circuitry and the low-voltage supply for digital circuits. In order to evaluate the radio frequency (RF) front end performance, the chip was measured using standard RFID testing equipment (CISC RFID Xplorer) [11] that allowed programming instructions to be sent to the RFID tags using standard RFID commands or user-defined commands by following the protocol definition. A continuous wave signal from the CISC RFID Xplorer was directly connected to the RF input of the proposed sensor chip for measurement purposes. The rectifier with an RF input level of 1.74 mW (2.4 dBm) had a power conversion efficiency (PCE) of 11.2% and produced 3.13 V across a 50-kΩ load, which was sufficient for circuit operations of the proposed sensor chip. Detailed descriptions of blocks and measurements could be found in previous studies [9,10].

2.2. Wireless Energy Harvesting and Antenna Design

In addition to the low power consumption requirement of sensor chips, limiting the energy source needed to sustain long-term sensing is another critical challenge for a wirelessly powered SCL system. It was challenging to supply the on-lens device with sufficient energy over an extended lifetime [12]. The sensor chip was wirelessly powered by an external electromagnetic (EM) energy source to avoid the need for batteries on the lens. It was also necessary to minimize the power consumption of the wireless monitoring system to sustain long-term bio-signal acquisition using low RF power. In conjunction with path and tissue losses, the relative location of the power transmitter (on the glasses) and receiver (on the lens) affects the amount of power received, especially for highly oriented small-size antennae. Thus, ring-type geometry was used in the sensor and antenna design due to the need to restrict the area of the components to avoid vision blockage. It was also necessary for the lens thickness to be close to that of commercial products to reduce contact lens discomfort [1]. This makes it difficult to locate matching and tuning components on the lens. A single-turn loop receiving antenna for UHF operation was implemented on the contact lens subject to these constraints. Impedance matching between the RFID sensor chip and antenna was achieved using the antenna profile by changing the segment length of the two wires and the gap spacing between them. Figure2a,b shows the prototypes and simulation results of the transmitting and receiving antennas, respectively. In order to further improve power transfer, a segmented antenna with a gap between the two loops was used to create a uniform magnetic field distribution [13]. The uniform field distribution of the proposed transmitting antenna could enhance energy transmission and provide robust operation with respect to shifts in the relative location and alignment of the contact lens and the glass caused by eye movement and blinking.

Sensors 2017, 17, 108 3 of 12

circuits, that is, the analog supply voltage for sensitive sensor readout circuitry and the low-voltage supply for digital circuits. In order to evaluate the radio frequency (RF) front end performance, the chip was measured using standard RFID testing equipment (CISC RFID Xplorer) [11] that allowed programming instructions to be sent to the RFID tags using standard RFID commands or user-defined commands by following the protocol definition. A continuous wave signal from the CISC RFID Xplorer was directly connected to the RF input of the proposed sensor chip for measurement purposes. The rectifier with an RF input level of 1.74 mW (2.4 dBm) had a power conversion efficiency (PCE) of 11.2% and produced 3.13 V across a 50-kΩ load, which was sufficient for circuit operations of the proposed sensor chip. Detailed descriptions of blocks and measurements could be found in previous studies [9,10].

2.2. Wireless Energy Harvesting and Antenna Design

In addition to the low power consumption requirement of sensor chips, limiting the energy source needed to sustain long-term sensing is another critical challenge for a wirelessly powered SCL system. It was challenging to supply the on-lens device with sufficient energy over an extended lifetime [12]. The sensor chip was wirelessly powered by an external electromagnetic (EM) energy source to avoid the need for batteries on the lens. It was also necessary to minimize the power consumption of the wireless monitoring system to sustain long-term bio-signal acquisition using low RF power. In conjunction with path and tissue losses, the relative location of the power transmitter (on the glasses) and receiver (on the lens) affects the amount of power received, especially for highly oriented small-size antennae. Thus, ring-type geometry was used in the sensor and antenna design due to the need to restrict the area of the components to avoid vision blockage. It was also necessary for the lens thickness to be close to that of commercial products to reduce contact lens discomfort [1]. This makes it difficult to locate matching and tuning components on the lens. A single-turn loop receiving antenna for UHF operation was implemented on the contact lens subject to these constraints. Impedance matching between the RFID sensor chip and antenna was achieved using the antenna profile by changing the segment length of the two wires and the gap spacing between them. Figure 2a,b shows the prototypes and simulation results of the transmitting and receiving antennas, respectively. In order to further improve power transfer, a segmented antenna with a gap between the two loops was used to create a uniform magnetic field distribution [13]. The uniform field distribution of the proposed transmitting antenna could enhance energy transmission and provide robust operation with respect to shifts in the relative location and alignment of the contact lens and the glass caused by eye movement and blinking.

(a) (b)

Figure 2. (a) Prototypes of transmitting (left) and receiving antennas (right); (b) Simulated |S11| of

transmitting antenna (left) and receiving antenna (right).

For safety reasons, it was necessary to maintain the increase in eye temperature under RF exposure to less than 1 °C [14]. An eye model with seven tissues [15], as shown in Figure 3a,b, was used to investigate the tissue influence and the specific absorption rate (SAR). The temperature increase in the eye tissue under short-term EM exposure can be obtained by a linear approximation of the bio-heat equation [14] as follows:

Sensor Lens Antenna 12.1mm Receiving Antenna Outer Loop : 57mm Inner Loop : 49mm Transmitting Antenna 0.8 0.9 1 1.1 1.2 -15 -10 -5 0 Return Loss frequency (GHz) S1 1 (d B) S11 S 1 1 ( d B ) Frequency (MHz) Receiving Antenna 800 900 1000 1100 1200 -25 -20 -15 -10 -5 0 Return Loss Frequency (MHz) S 1 1 ( d B ) S11 Transmitting Antenna Frequency (MHz) 800 900 1000 1100 1200 1000 1100 1200 900 800 S 1 1 ( d B ) -25 -20 -15 -10 -5 0 -15 -10 -5 0

Figure 2.(a) Prototypes of transmitting (left) and receiving antennas (right); (b) Simulated |S11| of transmitting antenna (left) and receiving antenna (right).

For safety reasons, it was necessary to maintain the increase in eye temperature under RF exposure to less than 1◦C [14]. An eye model with seven tissues [15], as shown in Figure3a,b, was used to investigate the tissue influence and the specific absorption rate (SAR). The temperature increase in the

(4)

Sensors 2017, 17, 108 4 of 12

eye tissue under short-term EM exposure can be obtained by a linear approximation of the bio-heat equation [14] as follows:

SAR=c∆T∆t (1)

where c denotes the heat capacity of the tissue,∆T denotes the temperature change, and ∆t denotes the exposure time. The maximum increase in temperature following 1 s of 30 dBm EM exposure corresponded to only 0.008◦C at 10 mm and 0.002◦C at 20 mm. A previous study discussed and summarized wireless energy harvesting, antenna design, and impact on eye tissues [10].

Sensors 2017, 17, 108 4 of 12

𝑆𝐴𝑅 = 𝑐∆𝑇

∆𝑡 (1)

where c denotes the heat capacity of the tissue, ΔT denotes the temperature change, and Δt denotes the exposure time. The maximum increase in temperature following 1 s of 30 dBm EM exposure corresponded to only 0.008 °C at 10 mm and 0.002 °C at 20 mm. A previous study discussed and summarized wireless energy harvesting, antenna design, and impact on eye tissues [10].

SAR simulation TX Antenna Power Input Eye Model

Distance between Tx and Rx

Model of SCL on the Eye

Contact Lens Sensor

Sclera Iris Lens Corneal Ciliary Muscle Anterior chamber Vitreous Humor Posterior chamber (a) (b)

Figure 3. (a) Configuration of the simulation; (b) Eye model for specific absorption rate (SAR) simulation.

2.3. Capacitive Sensor Design

Extant studies [7,8] presented the design and fabrication of an IOP capacitive sensor. Figure 4 shows the principle and fabrication process of the IOP capacitive sensor. The contact lens was placed tightly on the surface of the cornea, and thus the distance between the on-lens electrodes followed the curvature changes due to the IOP changes (from P1 to P2). The total capacitance is derived as follows: 𝐶(𝜃(𝛼)) = 𝑁𝜀𝑟𝜀0𝑤 tan 𝜃ln 𝑑 − 𝑙 tan 𝜃 + 𝑙 sin 𝜃 𝑑 − 𝑙 tan 𝜃 , 𝜃(𝛼) ≅ 𝜋 2 (∆𝑟 + 𝑑) + 𝛼𝑟 𝑟 + ∆𝑟 + 𝑑 (2)

where N denotes the number (18) of parallel capacitors, d denotes the gap distance (10 µ m), α denotes the angle between two ends of the capacitive sensor, and w (400 µ m) and l (100 µ m) denote the unit width and unit length of a unit capacitor, respectively. A micro capacitive sensor using top-down parallel plates was fabricated using MEMS methods on the HEMA substrate. The fabrication process is described as follows. First, a sacrificial copper (Cu) layer was sputtered on the Parylene-C substrate. The areas of the bottom capacitor electrodes and the loop antenna were formed by a lift-off process with titanium (Ti; 600 Å ) and gold (Au; 3500 Å ) and defined by a reactive-ion etching mask. The insulating layer was implemented with Parylene-C with 1 µ m thickness. The upper electrode was also formed with Titanium (Ti; 600 Å ) and gold (Au; 3500 Å ), which were defined after the photolithography and the lift-off process. Finally, the Cu sacrificial layer and the sacrificial layer between the parallel metal layers were removed. The sensor was placed on the inner area, and the antenna was placed outside a contact lens to maximize the effective area and efficiency.

In order to verify the characteristics of the capacitor sensor, the ex vivo porcine eye connected to a syringe pump was filled with increasing and decreasing amounts of water to generate periodical intraocular pressure variations between 0 mmHg and 4.5 mmHg for measurement. The measurements indicated that the sensitivity of the fabricated capacitive sensor corresponded to 4.4 fF/mmHg [8]. To compensate for the capacitance variation of the on-lens sensor owing to dielectric variation and various wearers’ eye conditions, the required capacitance detection range of sensor the readout circuitry was extended to 120 pF [7,8].

Figure 3. (a) Configuration of the simulation; (b) Eye model for specific absorption rate (SAR) simulation.

2.3. Capacitive Sensor Design

Extant studies [7,8] presented the design and fabrication of an IOP capacitive sensor. Figure4

shows the principle and fabrication process of the IOP capacitive sensor. The contact lens was placed tightly on the surface of the cornea, and thus the distance between the on-lens electrodes followed the curvature changes due to the IOP changes (from P1to P2). The total capacitance is derived as follows:

C(θ(α)) =Nεrε0w tan θ ln d−l tan θ+l sin θ d−l tan θ , θ(α) ∼= π 2(∆r+d) +αr r+∆r+d (2)

where N denotes the number (18) of parallel capacitors, d denotes the gap distance (10 µm), α denotes the angle between two ends of the capacitive sensor, and w (400 µm) and l (100 µm) denote the unit width and unit length of a unit capacitor, respectively. A micro capacitive sensor using top-down parallel plates was fabricated using MEMS methods on the HEMA substrate. The fabrication process is described as follows. First, a sacrificial copper (Cu) layer was sputtered on the Parylene-C substrate. The areas of the bottom capacitor electrodes and the loop antenna were formed by a lift-off process with titanium (Ti; 600 Å) and gold (Au; 3500 Å) and defined by a reactive-ion etching mask. The insulating layer was implemented with Parylene-C with 1 µm thickness. The upper electrode was also formed with Titanium (Ti; 600 Å) and gold (Au; 3500 Å), which were defined after the photolithography and the lift-off process. Finally, the Cu sacrificial layer and the sacrificial layer between the parallel metal layers were removed. The sensor was placed on the inner area, and the antenna was placed outside a contact lens to maximize the effective area and efficiency.

In order to verify the characteristics of the capacitor sensor, the ex vivo porcine eye connected to a syringe pump was filled with increasing and decreasing amounts of water to generate periodical intraocular pressure variations between 0 mmHg and 4.5 mmHg for measurement. The measurements indicated that the sensitivity of the fabricated capacitive sensor corresponded to 4.4 fF/mmHg [8].

(5)

Sensors 2017, 17, 108 5 of 12

To compensate for the capacitance variation of the on-lens sensor owing to dielectric variation and various wearers’ eye conditions, the required capacitance detection range of sensor the readout circuitry was extended to 120 pF [7,8]. Sensors 2017, 17, 108 5 of 12 r + ∆r r θ r α2 α1 IOP at Pressure P2 IOP at Pressure P1 Bottom Plate Top Plate Sensor Structure

Top View Sensor Structure : Cross-section View

Bottom Plate Top Plate Parylene - C

Si Cu Parylene - C Au/T

i PR

(a) Sputter Cu as sacrificial layer

(b) Define bottom electrode and antenna

(c) Spin coating PR as sacrificial layer

(d) Define top electrode

(e) Define sensor pattern

(f) Release components from wafer

Sensor Fabrication Process Operation Principle

Figure 4. Principle and fabrication process of the capacitive pressure sensor.

3. Materials and Methods

The SCL system included a capacitive sensor for eye healthcare monitoring, a silicon chip with readout circuitry and a UHF RFID Gen-2 wireless transceiver, and a small loop antenna. A reconfigurable capacitive sensor readout circuitry that occupied the same chip size as that used in a previous study [10] was employed in the design to overcome sensor variations during the fabrication and baseline drift of various wearers’ eye conditions. The sensor chip of our on-lens system is an integrated single chip solution dedicated to smart contact lens applications; and the chip size and geometrical dimensions were more optimized as compared with those of reported works [16–19]. The SCL system communicated with an on-glass RFID reader for sensing data collection, sensor control, and calibration for individuals. Furthermore, the on-lens system used commercially available bio-compatible HEMA hydrogel with a standard thickness of 200 μm and a commercial manufacturing process to reduce discomfort and increase compliance.

3.1. Design of the Sensor Readout Circuitry

Capacitive sensor interfaces are widely used when compared with resistive sensors due to inherent energy benefits and the absence of static current requirements [20,21]. The reconfigurable CDC proposed in this study provided moderate resolution, low power consumption, and a small chip area. It also simultaneously ensured the maximization of detection sensitivity as well detection range, and thus the proposed CDC was extremely suitable for the on-lens system in the study when compared with the CDCs reported in previous studies [20–23].

In order to improve the linearity and resolution of the readout circuitry, a 1-bit delta-sigma (Δ-Σ) modulator was adopted to convert the measured sensor value to a digital bit stream. The recorded bit density represented the relationship between the on-chip reference and the sensor value under

Figure 4.Principle and fabrication process of the capacitive pressure sensor.

3. Materials and Methods

The SCL system included a capacitive sensor for eye healthcare monitoring, a silicon chip with readout circuitry and a UHF RFID Gen-2 wireless transceiver, and a small loop antenna. A reconfigurable capacitive sensor readout circuitry that occupied the same chip size as that used in a previous study [10] was employed in the design to overcome sensor variations during the fabrication and baseline drift of various wearers’ eye conditions. The sensor chip of our on-lens system is an integrated single chip solution dedicated to smart contact lens applications; and the chip size and geometrical dimensions were more optimized as compared with those of reported works [16–19]. The SCL system communicated with an on-glass RFID reader for sensing data collection, sensor control, and calibration for individuals. Furthermore, the on-lens system used commercially available bio-compatible HEMA hydrogel with a standard thickness of 200 µm and a commercial manufacturing process to reduce discomfort and increase compliance.

3.1. Design of the Sensor Readout Circuitry

Capacitive sensor interfaces are widely used when compared with resistive sensors due to inherent energy benefits and the absence of static current requirements [20,21]. The reconfigurable CDC proposed in this study provided moderate resolution, low power consumption, and a small chip area. It also simultaneously ensured the maximization of detection sensitivity as well detection range, and thus the proposed CDC was extremely suitable for the on-lens system in the study when compared with the CDCs reported in previous studies [20–23].

(6)

Sensors 2017, 17, 108 6 of 12

In order to improve the linearity and resolution of the readout circuitry, a 1-bit delta-sigma (∆-Σ) modulator was adopted to convert the measured sensor value to a digital bit stream. The recorded bit density represented the relationship between the on-chip reference and the sensor value under the test. The converted digital bit stream was fed to a digital counter, and a decimation filter was used to remove undesired high-frequency fluctuations and out-of-band noise. The system model is shown in Figure5a, and a charge balancing process was used to illustrate the converter operation [20]. The negative feedback in the modulator ensured charge balance and resulted in a zero average charge flowing into the loop filter [20] as follows:

Qsensing−Qoff 

−D×Qref+ (1−D) ×Qref=0 (3)

where D denotes the bit density of the output bit stream BS (0≤D≤1). Solving for D results in the following expression:

D= Qsensing−Qoff

2×Qref

+1

2 (4)

which corresponds to the desired representation of the sensing charge Qsensing. The center of the charge conversion curve is denoted by Qoff, and the offset charge (denoted as Qoff) provides flexibility for baseline tuning. The sensitivity of conversion was inversely proportional to Qref, and the reference charge Qrefprovided sensitivity tuning and a detection range of 2Qref. The charge conversion curve is summarized in Figure5b.

Sensors 2017, 17, 108 6 of 12

the test. The converted digital bit stream was fed to a digital counter, and a decimation filter was used to remove undesired high-frequency fluctuations and out-of-band noise. The system model is shown in Figure 5a, and a charge balancing process was used to illustrate the converter operation [20]. The negative feedback in the modulator ensured charge balance and resulted in a zero average charge flowing into the loop filter [20] as follows:

(𝑄sensing− 𝑄off) − 𝐷 × 𝑄ref+ (1 − 𝐷) × 𝑄ref= 0 (3)

where D denotes the bit density of the output bit stream BS (0 ≤ D ≤ 1). Solving for D results in the following expression:

𝐷 =𝑄sensing− 𝑄off 2 × 𝑄ref +

1

2 (4)

which corresponds to the desired representation of the sensing charge Qsensing. The center of the charge

conversion curve is denoted by Qoff, and the offset charge (denoted as Qoff) provides flexibility for

baseline tuning. The sensitivity of conversion was inversely proportional to Qref, and the reference

charge Qref provided sensitivity tuning and a detection range of 2Qref. The charge conversion curve is

summarized in Figure 5b.

BS + 1 / - 1 INT_N Qoff Qsensing Qref Qsensing + -- Qoff ( )-D x Qref + (1 - D) x Qref = 0 D = Qsensing - Qoff 2Qref + 2 1 System model Qoff

Qoff - Qref Qoff + Qref

1

0.5

Qsensing(C)

Qref Qref

Charge conversion curve

R ec or de d bi t d en si ty D (a) (b)

Figure 5. (a) System model of the capacitance-to-digital converter (CDC); (b) Charge conversion curve

of the CDC.

The proposed reconfigurable CDC as shown in Figure 6a consisted of several capacitance arrays, an integrator, a comparator, an analog signal generator, and digital control circuits. For capacitive sensing, Qsensing = VINA × CSENSOR, Qoff = VINB × CSUB, and QREF = VREF × CREF. The capacitance detection

range of the proposed CDC is as follows: 𝐶SUB× 𝑉𝐼𝑁𝐵 𝑉𝐼𝑁𝐴− 𝐶REF× 𝑉𝑅𝐸𝐹 𝑉𝐼𝑁𝐴≤ 𝐶SENSOR≤ 𝐶SUB× 𝑉𝐼𝑁𝐵 𝑉𝐼𝑁𝐴+ 𝐶REF× 𝑉𝑅𝐸𝐹 𝑉𝐼𝑁𝐴 (5)

where VREF, VINA, and VINB denote the on-chip scalable voltage references, CREF denotes the

reference capacitor, and CSUB denotes the offset capacitor. Additionally, CSUB is used for coarsely

tuning the capacitor range, and CREF is applied for sensitivity tuning of the conversion gain. Voltage

scaling of VINB/VINA was used to further extend the capacitance detection range and prevented the implementation of large on-chip capacitors. The conversion behaviors of the proposed reconfigurable CDC are summarized in Figure 6b. The capacitor arrays and voltage references are wirelessly controlled by the commands from the on-glass RFID reader, and the maximum sensitivity and wide detection range could be simultaneously achieved with this topology.

Figure 5.(a) System model of the capacitance-to-digital converter (CDC); (b) Charge conversion curve of the CDC.

The proposed reconfigurable CDC as shown in Figure6a consisted of several capacitance arrays, an integrator, a comparator, an analog signal generator, and digital control circuits. For capacitive sensing, Qsensing= VINA×CSENSOR, Qoff= VINB×CSUB, and QREF= VREF×CREF. The capacitance detection range of the proposed CDC is as follows:

CSUB× V I NB V I N A−CREF× VREF V I N A ≤CSENSOR≤CSUB× V I NB V I N A +CREF× VREF V I N A (5)

where VREF, VINA, and VINB denote the on-chip scalable voltage references, CREF denotes the reference capacitor, and CSUBdenotes the offset capacitor. Additionally, CSUBis used for coarsely tuning the capacitor range, and CREFis applied for sensitivity tuning of the conversion gain. Voltage scaling of VINB/VINA was used to further extend the capacitance detection range and prevented the implementation of large on-chip capacitors. The conversion behaviors of the proposed reconfigurable CDC are summarized in Figure6b. The capacitor arrays and voltage references are wirelessly controlled by the commands from the on-glass RFID reader, and the maximum sensitivity and wide detection range could be simultaneously achieved with this topology.

(7)

Sensors 2017, 17, 108 7 of 12 Sensors 2017, 17, 108 7 of 12 VREF VREF D Q Clk Q CLK VREF CSENSOR CREF CFB Φ1 Φ2 Φ2 Φ2 If Q is L, Φ1 If Q is H, Φ1 If Q is L, Φ1 If Q is H, Φ1 VREF Φ2 Φ1 VINA VREF VREF VREF CSUB Φ2 Φ1 Φ1 Φ2 VINB OP CMP

Reference Capacitor Array

Offset Capacitor Array

Q Reconfigurable capacitance-to-digital converter

D =

Qsensing = CSENSOR x VINA

Qoff = CSUB x VINB, Qref = CREF x VREF

CSENSOR x VINA - CSUB x VINB

CREF x VREF x 2 + 2 1 VINB VINA

CSUB X CSUB XVINBVINA+ ∆C

VINB VINA

CSUB X - ∆C

∆C =CREF XVREFVINA

∆C ∆C R ec or de d bi t d en si ty D

Capacitance to digital conversion curve

1 0.5 CSENSOR CSENSOR D Group 1 Group 2 Baseline Tuning Sensitivity Tuning (a) (b)

Figure 6. (a) A schematic of the proposed reconfigurable CDC; (b) Conversion curve and tuning

behaviors of CDC.

3.2. Contact Lens Assembly Process

A general cast molding method was used to integrate the chip, receiving antenna, and biosensor on a soft contact lens with commercially available biocompatible materials. In order to reduce contact lens discomfort and increase compliance, it was necessary to fit the design of the contact lens to a standard (normal/universal/general) contact lens specification [1] involving thicknesses of 200 μm and 100 um at the peripheral and optical areas, respectively, of a contact lens. In this study, a standard contact lens fabrication process was utilized for the proposed smart contact lens packaging with hydrogel-based material. Figure 7a shows the process flow of the hydrogel-based contact lens biosensor system package with a pair of convex and concave contact lens molds. In the process, the proposed biosensor component was placed on a concave mold, and its center was aligned with the center of the mold. This was followed by pouring a hydrogel material into a concave mold and then combining the convex and concave molds. The contact lens with the molds was then cured with ultraviolet (UV) light. Finally, the mold was immersed into a hydration solution to facilitate a hydration reaction in the de-molding process. During the reaction, the contact lenses in the molds absorbed water to become soft and then could easily be detached from the molds. The proposed assembly process was compatible with a standard contact lens process, and it improved the edge smoothness and flatness of the contact lens. The assembly method helped in achieving a wrinkle-free smart contact lens as shown in Figure 7b.

(a) (b)

Figure 7. (a) Contact lens assembly process; (b) Assembled wrinkle free soft contact lens.

Figure 6. (a) A schematic of the proposed reconfigurable CDC; (b) Conversion curve and tuning behaviors of CDC.

3.2. Contact Lens Assembly Process

A general cast molding method was used to integrate the chip, receiving antenna, and biosensor on a soft contact lens with commercially available biocompatible materials. In order to reduce contact lens discomfort and increase compliance, it was necessary to fit the design of the contact lens to a standard (normal/universal/general) contact lens specification [1] involving thicknesses of 200 µm and 100 um at the peripheral and optical areas, respectively, of a contact lens. In this study, a standard contact lens fabrication process was utilized for the proposed smart contact lens packaging with hydrogel-based material. Figure7a shows the process flow of the hydrogel-based contact lens biosensor system package with a pair of convex and concave contact lens molds. In the process, the proposed biosensor component was placed on a concave mold, and its center was aligned with the center of the mold. This was followed by pouring a hydrogel material into a concave mold and then combining the convex and concave molds. The contact lens with the molds was then cured with ultraviolet (UV) light. Finally, the mold was immersed into a hydration solution to facilitate a hydration reaction in the de-molding process. During the reaction, the contact lenses in the molds absorbed water to become soft and then could easily be detached from the molds. The proposed assembly process was compatible with a standard contact lens process, and it improved the edge smoothness and flatness of the contact lens. The assembly method helped in achieving a wrinkle-free smart contact lens as shown in Figure7b.

Sensors 2017, 17, 108 7 of 12 VREF VREF D Q Clk Q CLK VREF CSENSOR CREF CFB Φ1 Φ2 Φ2 Φ2 If Q is L, Φ1 If Q is H, Φ1 If Q is L, Φ1 If Q is H, Φ1 VREF Φ2 Φ1 VINA VREF VREF VREF CSUB Φ2 Φ1 Φ1 Φ2 VINB OP CMP

Reference Capacitor Array

Offset Capacitor Array Q Reconfigurable capacitance-to-digital converter

D =

Qsensing = CSENSOR x VINA

Qoff = CSUB x VINB, Qref = CREF x VREF

CSENSOR x VINA - CSUB x VINB

CREF x VREF x 2 + 2 1 VINB VINA

CSUB X CSUB XVINBVINA+ ∆C

VINB VINA

CSUB X - ∆C

∆C =CREF XVREFVINA

∆C ∆C R ec or de d bi t d en si ty D

Capacitance to digital conversion curve

1 0.5 CSENSOR CSENSOR D Group 1 Group 2 Baseline Tuning Sensitivity Tuning (a) (b)

Figure 6. (a) A schematic of the proposed reconfigurable CDC; (b) Conversion curve and tuning

behaviors of CDC.

3.2. Contact Lens Assembly Process

A general cast molding method was used to integrate the chip, receiving antenna, and biosensor on a soft contact lens with commercially available biocompatible materials. In order to reduce contact lens discomfort and increase compliance, it was necessary to fit the design of the contact lens to a standard (normal/universal/general) contact lens specification [1] involving thicknesses of 200 μm and 100 um at the peripheral and optical areas, respectively, of a contact lens. In this study, a standard contact lens fabrication process was utilized for the proposed smart contact lens packaging with hydrogel-based material. Figure 7a shows the process flow of the hydrogel-based contact lens biosensor system package with a pair of convex and concave contact lens molds. In the process, the proposed biosensor component was placed on a concave mold, and its center was aligned with the center of the mold. This was followed by pouring a hydrogel material into a concave mold and then combining the convex and concave molds. The contact lens with the molds was then cured with ultraviolet (UV) light. Finally, the mold was immersed into a hydration solution to facilitate a hydration reaction in the de-molding process. During the reaction, the contact lenses in the molds absorbed water to become soft and then could easily be detached from the molds. The proposed assembly process was compatible with a standard contact lens process, and it improved the edge smoothness and flatness of the contact lens. The assembly method helped in achieving a wrinkle-free smart contact lens as shown in Figure 7b.

(a) (b)

Figure 7. (a) Contact lens assembly process; (b) Assembled wrinkle free soft contact lens.

(8)

Sensors 2017, 17, 108 8 of 12

4. Results

4.1. Sensor Chip Experiments

Figure8shows the chip micrograph of the proposed sensor IC. The chip was implemented using 0.18 µm CMOS technology. The dimensions of the chip with input and output pads corresponded to 1 mm×1.58 mm, and the CDC chip area corresponded to 0.64 mm×0.64 mm. The proposed CDC topology extended the maximum capacitance detection range from 50 pF to 120 pF within the same chip area when compared with that in a previous study [10]. The sensitivity was improved and could be tuned wirelessly by command programming.

Sensors 2017, 17, 108 8 of 12

4. Results

4.1. Sensor Chip Experiments

Figure 8 shows the chip micrograph of the proposed sensor IC. The chip was implemented using 0.18 μm CMOS technology. The dimensions of the chip with input and output pads corresponded to 1 mm × 1.58 mm, and the CDC chip area corresponded to 0.64 mm × 0.64 mm. The proposed CDC topology extended the maximum capacitance detection range from 50 pF to 120 pF within the same chip area when compared with that in a previous study [10]. The sensitivity was improved and could be tuned wirelessly by command programming.

Sensor Readout Circuitry Digital Processor Analog Front End 10 00 um 1580um

Figure 8. Die photo of the proposed sensor chip.

In order to confirm the sensor readout circuitry characteristics, the wired chip bonded on a print circuit board (PCB) was connected to commercial capacitors up to 120 pF for static capacitance conversion testing. The sensor chip was wirelessly powered by 20 dBm incident RF power from the RFID reader at a distance of 2 cm. Different reference capacitance values (denoted as CREF) were

selected for sensitivity tuning, and different voltage scaling ratios VINB/VINA were selected for baseline tuning. In order to evaluate the CDC conversion resolution, the effective number of bits (ENOB) calculation, as defined in a previous study [24], was used. The conversion results are shown in Figure 9. Table 1 shows performance summary and comparison with state-of-the-art CDC.

20 25 30 35 40 45 0 0.2 0.4 0.6 0.8 1 Capacitance (pF) N o rmaliz e d D o u t Baseline Tuning VINB / VINA=0.75 VINB / VINA=0.60 VINB / VINA=0.50 Baseline Tuning N o rm a li z e d D o u t R e c o r d e d B it D e n si ty 1 0.8 0.6 0.4 0.2 20 25 30 35 40 45 Capacitance (pF) 11 12 13 14 15 16 17 18 19 0 0.2 0.4 0.6 0.8 1 Sensitivity Tuning Capacitance (pF) N o rmaliz e d D o u t CREF=3.83pF CREF=2.34pF CREF=1.59pF CREF=0.84pF Sensitivity Tuning R ec o rd ed B it D en si ty 1 0.8 0.6 0.4 0.2 11 12 13 14 15 16 17 18 19 Capacitance (pF) (a) (b) 0 20 40 60 80 100 120 0 0.2 0.4 0.6 0.8 1 CDC Conversion Curve Capacitance (pF) N o rmaliz e d D o u t CDC Conversion Curve Capacitance (pF) Voltage Scaling R ec o rd ed B it D en si ty 0 20 40 60 80 100 120 9.5 10 10.5 11 Capacitance (pF) ENOB ENOB Capacitance (pF) 20 0 40 60 80 100 E N O B 11 10.5 10 9.5

Effective Number of Bits

120

(c) (d)

Figure 9. (a) Baseline tuning of the CDC; (b) Sensitivity tuning of the CDC; (c) CDC conversion curves;

(d) The ENOB of the CDC.

Figure 8.Die photo of the proposed sensor chip.

In order to confirm the sensor readout circuitry characteristics, the wired chip bonded on a print circuit board (PCB) was connected to commercial capacitors up to 120 pF for static capacitance conversion testing. The sensor chip was wirelessly powered by 20 dBm incident RF power from the RFID reader at a distance of 2 cm. Different reference capacitance values (denoted as CREF) were selected for sensitivity tuning, and different voltage scaling ratios VINB/VINA were selected for baseline tuning. In order to evaluate the CDC conversion resolution, the effective number of bits (ENOB) calculation, as defined in a previous study [24], was used. The conversion results are shown in Figure9. Table1shows performance summary and comparison with state-of-the-art CDC.

Sensors 2017, 17, 108 8 of 12

4. Results

4.1. Sensor Chip Experiments

Figure 8 shows the chip micrograph of the proposed sensor IC. The chip was implemented using 0.18 μm CMOS technology. The dimensions of the chip with input and output pads corresponded to 1 mm × 1.58 mm, and the CDC chip area corresponded to 0.64 mm × 0.64 mm. The proposed CDC topology extended the maximum capacitance detection range from 50 pF to 120 pF within the same chip area when compared with that in a previous study [10]. The sensitivity was improved and could be tuned wirelessly by command programming.

Sensor Readout Circuitry Digital Processor Analog Front End 10 00 um 1580um

Figure 8. Die photo of the proposed sensor chip.

In order to confirm the sensor readout circuitry characteristics, the wired chip bonded on a print circuit board (PCB) was connected to commercial capacitors up to 120 pF for static capacitance conversion testing. The sensor chip was wirelessly powered by 20 dBm incident RF power from the RFID reader at a distance of 2 cm. Different reference capacitance values (denoted as CREF) were

selected for sensitivity tuning, and different voltage scaling ratios VINB/VINA were selected for baseline tuning. In order to evaluate the CDC conversion resolution, the effective number of bits (ENOB) calculation, as defined in a previous study [24], was used. The conversion results are shown in Figure 9. Table 1 shows performance summary and comparison with state-of-the-art CDC.

20 25 30 35 40 45 0 0.2 0.4 0.6 0.8 1 Capacitance (pF) N o rmaliz e d D o u t Baseline Tuning VINB / VINA=0.75 VINB / VINA=0.60 VINB / VINA=0.50 Baseline Tuning N o rm a li z e d D o u t R e c o r d e d B it D e n si ty 1 0.8 0.6 0.4 0.2 20 25 30 35 40 45 Capacitance (pF) 11 12 13 14 15 16 17 18 19 0 0.2 0.4 0.6 0.8 1 Sensitivity Tuning Capacitance (pF) N o rmaliz e d D o u t CREF=3.83pF CREF=2.34pF CREF=1.59pF CREF=0.84pF Sensitivity Tuning R ec o rd ed B it D en si ty 1 0.8 0.6 0.4 0.2 11 12 13 14 15 16 17 18 19 Capacitance (pF) (a) (b) 0 20 40 60 80 100 120 0 0.2 0.4 0.6 0.8 1 CDC Conversion Curve Capacitance (pF) N o rmaliz e d D o u t CDC Conversion Curve Capacitance (pF) Voltage Scaling R ec o rd ed B it D en si ty 0 20 40 60 80 100 120 9.5 10 10.5 11 Capacitance (pF) ENOB ENOB Capacitance (pF) 20 0 40 60 80 100 E N O B 11 10.5 10 9.5

Effective Number of Bits

120

(c) (d)

Figure 9. (a) Baseline tuning of the CDC; (b) Sensitivity tuning of the CDC; (c) CDC conversion curves;

(d) The ENOB of the CDC.

Figure 9.(a) Baseline tuning of the CDC; (b) Sensitivity tuning of the CDC; (c) CDC conversion curves; (d) The ENOB of the CDC.

(9)

Sensors 2017, 17, 108 9 of 12

Table 1.A comparison of the performance of the capacitance-to-digital converter used in the present study to those used in previous studies.

[20] [21] [22] [23] This Work

Type ∆-Σ Dual-Slope PWM ∆-Σ ∆-Σ

Input Range 0.54–1.06 pF 5.3–30.7 pF 1–6.8 pF 8.4–11.6 pF 1.5–120 pF

Chip Area 0.28 mm2 N/A 0.51 mm2 2.6 mm2 0.41 mm2

Power 10.3 µW 110 nW 210 µW 14.9 mW 100 µW

ENOB 12.5 bits 7.05 bits 15 bits 15.3 bits 9.7 bits

4.2. Wirelessly Powered SCL Expeiments

The porcine eye (LYD pigs, Guan Dong Market, Hsinchu city, Taiwan, R.O.C) connected to a syringe pump was filled with increasing and decreasing amounts of water to generate periodical intraocular pressure variations in the range of 2.25 and 30 mmHg for measurement purposes. A 20 s pressure variation period was used in the study. The RFID reader was placed at a distance of 1 cm to wirelessly record IOP pressure variation. The photograph of the measurement setup is shown in Figure10.

Sensors 2017, 17, 108 9 of 12

Table 1. A comparison of the performance of the capacitance-to-digital converter used in the present study to those used in previous studies.

[20] [21] [22] [23] This Work

Type Δ-Σ Dual-Slope PWM Δ-Σ Δ-Σ

Input Range 0.54–1.06 pF 5.3–30.7 pF 1–6.8 pF 8.4–11.6 pF 1.5–120 pF

Chip Area 0.28 mm2 N/A 0.51 mm2 2.6 mm2 0.41 mm2

Power 10.3 μW 110 nW 210 μW 14.9 mW 100 μW

ENOB 12.5 bits 7.05 bits 15 bits 15.3 bits 9.7 bits

4.2. Wirelessly Powered SCL Expeiments

The porcine eye (LYD pigs, Guan Dong Market, Hsinchu city, Taiwan, R.O.C) connected to a syringe pump was filled with increasing and decreasing amounts of water to generate periodical intraocular pressure variations in the range of 2.25 and 30 mmHg for measurement purposes. A 20 s pressure variation period was used in the study. The RFID reader was placed at a distance of 1 cm to wirelessly record IOP pressure variation. The photograph of the measurement setup is shown in Figure 10.

Figure 10. The experimental setup.

The sensor lens was wirelessly powered by a 26.5 dBm incident RF power from the RFID reader at 920 MHz frequency. Real-time periodical IOP measuring data were directly monitored on a PC and recorded for future clinical study purposes. The recorded periodical IOP pressure variation is shown in Figure 11a. As indicated by the measurement results, the dynamic range of sensor readout circuitry of the proposed sensor lens achieved the IOP range requirement of 2.25–30 mmHg. There is a time delay between the capacitance variation and pressure gauge readings because the IOP is changed by the increasing and decreasing amounts of water. The water was injected and then drained from the pig eye to change the IOP, thus causing a time delay. In addition to IOP measurement, the dielectric capacity increased as the water content increased and vice versa. Figure 11b shows the long-term capacitance change due to the hydration level variation from SCL with the same experiment setup as that shown in Figure 10. The measurements indicated that the proposed SCL could also be used for hydration level detection in the future. Table 2 compares the results with those of state-of-the-art IOP monitoring systems. The proposed design achieved a power consumption of only 110 μW and used RFID addressable communication for sensor control and data communication. With the proposed CDC topology, the maximum sensitivity and wide detection range can be achieved simultaneously. The sensor chip of our on-lens system is an integrated single chip solution dedicated to smart contact lens applications; the chip size and geometrical dimensions were more optimized as

Figure 10.The experimental setup.

The sensor lens was wirelessly powered by a 26.5 dBm incident RF power from the RFID reader at 920 MHz frequency. Real-time periodical IOP measuring data were directly monitored on a PC and recorded for future clinical study purposes. The recorded periodical IOP pressure variation is shown in Figure11a. As indicated by the measurement results, the dynamic range of sensor readout circuitry of the proposed sensor lens achieved the IOP range requirement of 2.25–30 mmHg. There is a time delay between the capacitance variation and pressure gauge readings because the IOP is changed by the increasing and decreasing amounts of water. The water was injected and then drained from the pig eye to change the IOP, thus causing a time delay. In addition to IOP measurement, the dielectric capacity increased as the water content increased and vice versa. Figure11b shows the long-term capacitance change due to the hydration level variation from SCL with the same experiment setup as that shown in Figure10. The measurements indicated that the proposed SCL could also be used for hydration level detection in the future. Table2compares the results with those of state-of-the-art IOP monitoring systems. The proposed design achieved a power consumption of only 110 µW and used RFID addressable communication for sensor control and data communication. With the proposed CDC topology, the maximum sensitivity and wide detection range can be achieved simultaneously.

(10)

Sensors 2017, 17, 108 10 of 12

The sensor chip of our on-lens system is an integrated single chip solution dedicated to smart contact lens applications; the chip size and geometrical dimensions were more optimized as compared with those of reported works [3,5,6]. Moreover, the proposed sensor system integrated with a 200-µm thickness contact lens using HEMA hydrogel and standard process can improve discomfort and compliance issues related to contact lenses.

Sensors 2017, 17, 108 10 of 12

compared with those of reported works [3,5,6]. Moreover, the proposed sensor system integrated with a 200-μm thickness contact lens using HEMA hydrogel and standard process can improve discomfort and compliance issues related to contact lenses.

10 20 30 40 50 60 70 80 90 100 60 60.5 61 IOP Measurement Time (sec) C a p a c it a n c e R e a d o u t (p F ) 10 20 30 40 50 60 70 80 90 1000 10 20 30 P re s s u re V a ri a ti o n ( m m H g ) IOP Measurement IO P P re ss u re ( m m H g ) 0 10 20 30 2.25 C a p a ci ta n ce ( p F ) 61.0 60.5 60.0 10 30 50 70 90 100 Time (sec) 0 50 100 150 200 59 59.5 60 60.5 61 Time (sec) Ca p a cita n ce ( p F )

Hydration Level Variation

Time (sec) C a p a ci ta n ce ( p F ) (a) (b)

Figure 11. (a) Intraocular pressure (IOP) measurement results; (b) Hydration level measurement

results.

Table 2. A comparison of the intraocular pressure monitoring system in the present study with those

used in previous studies.

References [3] [5] [6] This Work

Type Implantable Implantable Wearable Wearable

Communication

Technique Active Load Modulation N/A Load Modulation

Frequency 2.5 GHz 13.56 MHz 27 MHz 920 MHz

Power Consumption 1.4 mW 1.2 mW N/A 110 μW

Communication

Distance N/A 4 cm N/A 1 cm

Sensor Type Capacitive Resistive Resistive Capacitive

Sensor Range 5.3 pF–5.75 pF 5 KΩ–50 KΩ N/A 1.5 pF–120 pF

ENOB N/A 8 N/A 9.7

Chip Size 0.5 mm2 2 mm2 N/A 1.58 mm2

Communication

Protocol N.A ISO-15693 N/A EPC Class1 Gen2

Lens Thickness N/A N/A 400 μm 200 μm

Lens Material N/A N/A Silicone HEMA

5. Discussion and Conclusions

In this study, a wirelessly powered smart contact lens system was proposed for non-invasive and long-term IOP monitoring. The system was composed of an energy transmitter, antennae, and an on-lens sensing device. The proposed SCL system could be wirelessly powered and was able to communicate with commercial Gen2 RFID-compatible equipment to demonstrate periodical IOP pressure variation and hydration level variation measurements. The on-lens system used commercially available bio-compatible HEMA hydrogel with a standard 200-μm thickness and a commercial manufacturing process, and this reduced discomfort and increased compliance. A successful sensor readout distance of 1 cm was achieved under 26.5-dBm incident RF power at a UHF RFID frequency of 920 MHz. The proposed design exhibited low power consumption and was fully integrated onto contact lens material using a standard manufacturing process. The range and sensitivity tuning of reconfigurable readout circuitry provided a reliable operation over sensor fabrication variations. Hydration level detection will be examined in future studies to further extend the application of the proposed SCL system.

Figure 11.(a) Intraocular pressure (IOP) measurement results; (b) Hydration level measurement results.

Table 2.A comparison of the intraocular pressure monitoring system in the present study with those used in previous studies.

References [3] [5] [6] This Work

Type Implantable Implantable Wearable Wearable

Communication Technique Active Load Modulation N/A Load Modulation

Frequency 2.5 GHz 13.56 MHz 27 MHz 920 MHz

Power Consumption 1.4 mW 1.2 mW N/A 110 µW

Communication Distance N/A 4 cm N/A 1 cm

Sensor Type Capacitive Resistive Resistive Capacitive Sensor Range 5.3 pF–5.75 pF 5 KΩ–50 KΩ N/A 1.5 pF–120 pF

ENOB N/A 8 N/A 9.7

Chip Size 0.5 mm2 2 mm2 N/A 1.58 mm2

Communication Protocol N.A ISO-15693 N/A EPC Class1 Gen2

Lens Thickness N/A N/A 400 µm 200 µm

Lens Material N/A N/A Silicone HEMA

5. Discussion and Conclusions

In this study, a wirelessly powered smart contact lens system was proposed for non-invasive and long-term IOP monitoring. The system was composed of an energy transmitter, antennae, and an on-lens sensing device. The proposed SCL system could be wirelessly powered and was able to communicate with commercial Gen2 RFID-compatible equipment to demonstrate periodical IOP pressure variation and hydration level variation measurements. The on-lens system used commercially available bio-compatible HEMA hydrogel with a standard 200-µm thickness and a commercial manufacturing process, and this reduced discomfort and increased compliance. A successful sensor readout distance of 1 cm was achieved under 26.5-dBm incident RF power at a UHF RFID frequency of 920 MHz. The proposed design exhibited low power consumption and was fully integrated onto contact lens material using a standard manufacturing process. The range and sensitivity tuning of reconfigurable readout circuitry provided a reliable operation over sensor fabrication variations. Hydration level detection will be examined in future studies to further extend the application of the proposed SCL system.

(11)

Sensors 2017, 17, 108 11 of 12

Acknowledgments:This work was supported in part by the Ministry of Science and Technology, Taiwan, R.O.C. (under Contract Number: MOST 105-2218-E-009-018 and MOST 103-2221-E-009-192-MY3). The authors would like to thank the National Chip Implementation Center for chip fabrication. The authors express their gratitude to CISC Semiconductor for technical assistance for the CISC RFID Xplorer.

Author Contributions: All authors considerably contributed to this article. The article was conceived and structured by all the authors who contributed to writing, reading and approving the final manuscript. Jin-Chern Chiou performed the conceptual design. Shun-Hsi Hsu performed the system integration and measurements, and developed the sensor chip. Yu-Chieh Huang performed the system validation. Guan-Ting Yeh and Wei-Ting Liou developed an on-lens capacitive sensor and performed sensor fabrication and contact lens assembly. Cheng-Kai Kuei performed the antenna design and implementation. Jin-Chern Chiou, Shun-Hsi Hsu, Yu-Chieh Huang, Guan-Ting Yeh, Wei-Ting Liou, and Cheng-Kai Kuei wrote the paper.

Conflicts of Interest:The authors declare no conflict of interest.

References

1. Sirinivasan, S.; Subbaraman, L.N. The science of contact lens discomfort. Opt. J. Rev. Optom. 2015, 152, 34–39. 2. Piso, D.; Veiga-Crespo, P.; Vecino, E. Modern monitoring intraocular pressure sensing devices based on

application specific integrated circuits. J. Biomater. Nanobiotechnol. 2012, 3, 301–309. [CrossRef]

3. Chow, E.Y.; Chlebowski, A.L.; Oqui, P.P. A miniature-implantable RF-wireless active glaucoma intraocular pressure monitor. IEEE Trans. Biomed. Circuits Syst. 2010, 4, 340–349. [CrossRef] [PubMed]

4. Chen, G.; Ghaed, H.; Haque, R.; Wieckowski, M.; Kim, Y.; Kim, G.; Fick, D.; Kim, D.; Seok, M.; Wise, K.; et al. A cubic-millimeter energy-autonomous wireless intraocular pressure monitor. In Proceedings of the IEEE International Solid-State Circuits Conference Digest of Technical Papers, San Francisco, CA, USA, 20–24 February 2011; pp. 310–311.

5. Donida, A.; Dato, G.D.; Cunzolo, P.; Sala, M.; Piffaretti, F.; Orsatti, P.; Barrettino, D. A 0.036 mbar circadian and cardiac intraocular pressure sensor for smart implantable lens. In Proceedings of 2015 IEEE International Solid-State Circuits Conference, San Francisco, CA, USA, 22–26 February 2015; pp. 392–393.

6. Leonardi, M.; Pitchon, E.; Bertsch, A.; Renaud, P.; Mermoud, A. Wireless contact lens sensor for intraocular pressure monitoring: Assessment on enucleated pig eyes. Acta Ophthalmol. 2009, 87, 433–437. [CrossRef] [PubMed]

7. Chiou, J.C.; Huang, Y.C.; Yeh, G.T. A capacitor-based sensor and a contact lens sensing system for intraocular pressure monitoring. J. Micromech. Microeng. 2015, 26, 015001. [CrossRef]

8. Yeh, G.T.; Wu, T.W.; Tsai, S.W.; Hsu, S.H.; Chiou, J.C. Toward a wireless contact lens sensor system with a micro-capacitor for intraocular pressure monitoring on in vitro porcine eye. In Proceedings of the IEEE Sensors, Busan, Korea, 1–4 November 2015; pp. 1–4.

9. Hsu, S.H.; Chiou, J.C.; Liao, Y.T.; Yang, T.S.; Kuei, C.K.; Wu, T.W.; Huang, Y.C. An RFID-based on-lens sensor system for long-term IOP monitoring. In Proceedings of the 37th Annual International Conference IEEE Engineering in Medicine and Biology Society, Milan, Italy, 25–29 August 2015; pp. 7526–7529.

10. Chiou, J.C.; Hsu, S.H.; Liao, Y.T.; Huang, Y.C.; Yeh, G.T.; Kuei, C.K.; Dai, D.K. Toward a wirelessly powered on-lens intraocular pressure monitoring system. IEEE J. Biomed. Health Inform. 2016, 20, 1216–1224. [CrossRef] [PubMed]

11. CISC RFID Xplorer Equipment Information. Available online: https://www.cisc.at/products/rfid-xplorer (accessed on 11 December 2016).

12. Yang, G.Z. Body Sensor Networks; Springer: London, UK, 2006.

13. Qing, X.; Goh, C.K.; Chen, Z.N. Eye-shaped segmented reader antenna for near-field UHF RFID applications. Electron. Lett. 2009, 45, 872–873. [CrossRef]

14. IEEE Standard for Safety Levels With Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz; IEEE Std C95.1-2005 (Revision of IEEE Std C95.1-1991); IEEE: New York, NY, USA, April 2006. 15. Wessapan, T.; Rattanadecho, P. Specific absorption rate and temperature increase in the human eye due to

electromagnetic fields exposure at different frequencies. Int. J. Heat Mass Transf. 2013, 64, 426–435. [CrossRef] 16. LPS25H MEMS Pressure Sensor. Available online: http://www.st.com/en/mems-and-sensors/lps25h.html

(accessed on 11 December 2016).

17. ANDY100—RFID Tag Chips that Supply and Communicate with External Sensors. Available online: http://www.farsens.com/en/products/andy100 (accessed on 11 December 2016).

(12)

Sensors 2017, 17, 108 12 of 12

18. SL900A EPC Sensor Tag—EPC Sensor Tag and Data Logger IC. Available online: http://ams.com/eng/ Products/Wireless-Connectivity/Sensor-Tags-Interfaces/SL900A (accessed on 11 December 2016). 19. Cho, N.; Song, S.J.; Kim, S.Y.; Kim, S.H.; Yoo, H.J. A 5.1-µW UHF RFID tag chip integrated with sensors for

wireless environmental monitoring. In Proceedings of the 31st European Solid-State Circuits Conference, Grenoble, France, 12–16 September 2005; pp. 279–282.

20. Tan, Z.; Daamen, R.; Humbert, A.; Ponomarev, Y.V.; Chae, Y.; Pertijs, M.A.P. A 1.2-V 8.3-nJ CMOS humidity sensor for RFID applications. IEEE J. Solid-State Circuits 2013, 48, 2469–2477. [CrossRef]

21. Oh, S.; Lee, Y.; Wang, J.; Foo, Z.; Kim, Y.; Jung, W.; Li, Z.; Blaauw, D.; Sylvester, D. A dual-slope capacitance-to-digital converter integrated in an implantable pressure-sensing system. IEEE J. Solid-State Circuits 2015, 50, 1581–1591. [CrossRef]

22. Tan, Z.; Shalmany, S.H.; Meijer, G.C.M.; Pertijs, M.A.P. An energy-efficient 15-bit capacitive-sensor interface based on period modulation. IEEE J. Solid-State Circuits 2012, 47, 1703–1711. [CrossRef]

23. Xia, S.; Makinwa, K.; Nihtianov, S. A capacitance-to-digital converter for displacement sensing with 17b resolution and 20 µs conversion time. In Proceedings of 2012 IEEE International Solid-State Circuits Conference Digest of Technical Papers (ISSCC), San Francisco, CA, USA, 19–23 February 2012; pp. 198–199. 24. Heidary, A.; Meijer, G.C.M. Features and design constraints for an optimized SC front-end circuit for

capacitive sensors with a wide dynamic range. IEEE J. Solid-State Circuits 2008, 43, 1609–1616. [CrossRef] © 2017 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access

article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).

數據

Figure 1. (a) Proposed smart contact lens (SCL) system architecture; (b) Block diagram of the proposed  smart contact lens
Figure  3.  (a)  Configuration  of  the  simulation;  (b)  Eye  model  for  specific  absorption  rate  (SAR)  simulation
Figure 4. Principle and fabrication process of the capacitive pressure sensor.
Figure 5. (a) System model of the capacitance-to-digital converter (CDC); (b) Charge conversion curve  of the CDC
+4

參考文獻

相關文件

In addition to examining the influence that the teachings of Zen had on Shi Tao’s art and theoretical system, this paper proposes further studies on Shi Tao’s interpretation on

1) Ensure that you have received a password from the Indicators Section. 2) Ensure that the system clock of the ESDA server is properly set up. 3) Ensure that the ESDA server

Microphone and 600 ohm line conduits shall be mechanically and electrically connected to receptacle boxes and electrically grounded to the audio system ground point.. Lines in

– Each listener may respond to a different kind of  event or multiple listeners might may respond to event, or multiple listeners might may respond to 

Abstract—We propose a multi-segment approximation method to design a CMOS current-mode hyperbolic tangent sigmoid function with high accuracy and wide input dynamic range.. The

The exploration of the research can be taken as a reference that how to dispose the resource when small and medium enterprise implement management information system.. The

Research on Analog and Mixed-Signal Processing Integrated Circuit Design for ISFET-Based Linear Sensor Array

Most of the studies used these theme parks as a research object and mainly focused on service quality, customer satisfaction and possible reasons that influence the willingness of