• 沒有找到結果。

AGP3301-S1-D24手册Proface触摸屏AGP3301-S1-D24欧姆龙CS/CJ系列可编程控制器梯形图监控操作手册_广州菱控

N/A
N/A
Protected

Academic year: 2022

Share "AGP3301-S1-D24手册Proface触摸屏AGP3301-S1-D24欧姆龙CS/CJ系列可编程控制器梯形图监控操作手册_广州菱控"

Copied!
43
0
0

加載中.... (立即查看全文)

全文

(1)

Operation Manual

OMRON Corporation

CS/CJ Series

PLC Ladder Monitor

(2)

PLC Ladder Monitor Operation Manual

1

Introduction

Thank you for purchasing the PLC Ladder Monitor Add-on Kit for the OMRON Corporation CS/CJ Series. This manual explains the operation for monitoring the ladder programs of the external device and device addresses using the GP3000 Series programmable Display manufactured by Pro-face (Digital Electronics Corporation).

Please read the manual thoroughly for proper use of this product.

Be sure the manual is always available where this product is used.

© Copyright 2008 Digital Electronics Corporation. All rights reserved.

All product names described herein are trademarks or registered trademarks of the respective owners.

Note

(1) All programs and manuals of “PLC Ladder Monitor Add-on Kit for OMRON

Corporation’s CS/CJ Series” (called the product, hereafter) are copyright of Digital Electronics Corporation and Digital Electronics Corporation shall grant the users the license as described in “Software License”. Any conduct violating the “Software License” is prohibited by the laws and regulations in Japan and other countries.

(2) The manual has been prepared for additional assurance. Should you have any concerns, please contact Digital Electronics Corporation’s “Support Line”.

(3) Notwithstanding the previous paragraph, Digital Electronics Corporation shall not be responsible for any damage or other loss, or any claims from a third party as a result of using this product.

(4) Some parts and product software may differ from the description in the manual due to product improvements. For the latest descriptions, see also the separate document and on-line information.

(5) The product may record/display some information containing intangible or intellectual property belonging to Digital Electronics Corporation. This shall not grant the users or third parties a guarantee or license for these properties of Digital Electronics

Corporation. Digital Electronics Corporation shall not be held responsible for any problems arising from the recording/displaying of a third party’s intellectual property using this product.

(3)

Manual Description

This manual provides following cautions for proper use of the PLC Ladder Monitor Add-on Kit for the OMRON Corporation CS/CJ Series. The cautions described herein contain important safety informaiton. The following table shows the symbols and what they mean.

Package Content

CD-ROM: 1 User registry

FAX sheet: 1 for Japanese/

English each

Serial barcode sticker: 1

KEYCODE sticker: 1

(Placed on the CD case)

Symbol Meaning

Failure to follow the instructions on the display may result in adverse events such as device errors or data loss.

Important points for use.

* The footnotes contain an explanation of the annotated words.

)

Related reference pages are provided.

PLC Programmable Logic Controller.

Package Content

(4)

PLC Ladder Monitor Operation Manual

3

Supported Models

„ Supporting External Devices

Maker Series

Name CPU Model Link I/F Connection Method*1

Driver Name on GP- Pro EX (Version)*2

OMRON Corporation

CS1 series

CS1H-CPU67 CS1H-CPU66 CS1H-CPU65 CS1H-CPU64 CS1G-CPU45 CS1G-CPU44 CS1G-CPU43 CS1G-CPU42 CS1H-CPU67H CS1H-CPU66H CS1H-CPU65H CS1H-CPU64H CS1H-CPU63H CS1G-CPU45H CS1G-CPU44H CS1G-CPU43H CS1G-CPU42H CS1H-CPU67-V1 CS1H-CPU66-V1 CS1H-CPU65-V1 CS1H-CPU64-V1 CS1H-CPU63-V1 CS1G-CPU45-V1 CS1G-CPU44-V1 CS1G-CPU43-V1 CS1G-CPU42-V1

RS232C port on the CPU unit

RS-232C or RS-422/485 (4wire)

CS/CJ series HOST link (V1.13.02 or later) Peripheral port

on the CPU unit

CS1W-SCU21 CS1W-SCU21-V1 CS1W-SCB21 CS1W-SCB41

CS1W-ETN01 CS1W-ETN11 CS1W-ETN21*3

Ethernet

CS/CJ Series Ethernet

(V1.14.03 or later)

CJ1 Series

CJ1G-CPU45 CJ1G-CPU44 CJ1M-CPU23 CJ1M-CPU22 CJ1M-CPU21 CJ1M-CPU13 CJ1M-CPU12 CJ1M-CPU11 CJ1H-CPU67H CJ1H-CPU66H CJ1H-CPU65H CJ1H-CPU67H-R CJ1H-CPU66H-R CJ1H-CPU65H-R CJ1H-CPU64H-R CJ1G-CPU45H CJ1G-CPU44H CJ1G-CPU43H CJ1G-CPU42H

RS232C port on the CPU unit

RS-232C or RS-422/485 (4wire)

CS/CJ Series HOST link (V1.13.02 or later) Peripheral port

on the CPU unit

CJ1W-SCU41 CJ1W-SCU21 CJ1W-SCU41-V1 CJ1W-SCU31-V1 CJ1W-SCU21-V1

CJ1W-ETN01 CJ1W-ETN11 CJ1W-ETN21*3

Ethernet

CS/CJ Series Ethernet

(V1.14.03 or later)

(5)

Maker Series

Name CPU Model Link I/F Connection Method*1

Driver Name on GP- Pro EX (Version)*2

OMRON Corporation

CP1 Series

CP1L-M

††

D

†

-

†

CP1L-L

††

D

†

-

†

CP1W-CIF01 RS-232C

CS/CJ Series HOST link (V1.13.02 or later) CP1W-CIF11 RS-422/485

(4wire)

CP1H-X

††

D

†

-

†

CP1H-XA

††

D

†

-

†

CP1H-Y

††

D

†

-

†

CP1W-CIF01 RS-232C CP1W-CIF11 RS-422/485

(4wire) CJ1W-SCU41

CJ1W-SCU21 CJ1W-SCU41-V1 CJ1W-SCU31-V1 CJ1W-SCU21-V1

RS-232C or RS-422/485 (4wire)

CJ1W-ETN21*3 Ethernet

CS/CJ Series Ethernet

(V1.14.03 or later)

*1 Communication mode changes according to type of link unit, cables used, etc. For details, see the relevant driver manuals.

*2 The driver version can be checked by viewing [Peripheral List] in the [System Settings]

window on the GP-Pro EX, or [Driver Version] on [Offline Home] on the display.

*3 Compatible with both Ethernet transfer protocols, UDP/IP and TCP/IP.

• If the driver version of a device connected to the GP-Pro EX is older than that indicated in the table, the ladder monitor will not function normally. You must upgrade the driver to at least the version indicated in the table before using the unit. For the update module, please download it from the Pro-face support site “Otasuke Pro!”.

(URL http://www.pro-face.com/otasuke/)

(6)

PLC Ladder Monitor Operation Manual

5

„ Relevant Display

Displays that support the ladder monitor are GP3000 Series models with VGA, SVGA, and XVGA resolution. For details on supported models, see the table below.

„ Screen Creation Software by Pro-face (Digital Electronics Corporation)

GP-Pro EX Ver.2.00 or later

„ OMRON Corporation Programming Tools

CX-Programmer Series Ver.7 or earlier

Series Models

GP3000 series

GP-3300 series AGP-3310HT

GP-3400 series

AGP-3400S AGP-3400S-D81 AGP-3400S-CA1M AGP-3400T

AGP-3400T-D81 AGP-3400T-FN1M AGP-3400T-CA1M AGP-3450T

GP-3500 series

AGP-3500L AGP-3500L-D81 AGP-3500S AGP-3500S-D81 AGP-3500S-CA1M AGP-3500T

AGP-3500T-D81 AGP-3500T-FN1M AGP-3500T-CA1M AGP-3510T AGP-3510T-CA1M AGP-3550T AGP-3560T

GP-3600 series

AGP-3600T AGP-3600T-D81 AGP-3600T-FN1M AGP-3600T-CA1M AGP-3650T GP-3700 series AGP-3750T

• Refer below for the compatible external device versions.

)

„ Supporting External Devices (page 3)

• Instructions that can be monitored using this function are those supported by the CX-Programmer Series Ver.7 or earlier programming tool by OMRON Corporation.

(7)
(8)

PLC Ladder Monitor Operation Manual

7

Table of Contents

Introduction ... 1

Manual Description ... 2

Package Content ... 2

Supported Models ... 3

Table of Contents ... 7

Chapter 1 Summary

1.1 Ladder Monitor ... 1-2 1.2 System Configuration ... 1-3 1.3 Installation Procedure ... 1-6

Chapter 2 Using the Ladder Monitor

2.1 Settings Menu ... 2-2 2.2 Monitoring the Ladder Programs of the External Device on a Display ... 2-3 2.2.1 Details ... 2-3 2.2.2 Setup Procedure ... 2-4 2.3 Displaying Ladder Programs in Alarm History View ... 2-11 2.3.1 Details ... 2-11 2.3.2 Setup Procedure ... 2-11 2.4 Printing the Ladder Monitor View from a Display ... 2-13 2.4.1 Details ... 2-13 2.4.2 Setup Procedure ... 2-13 2.5 Capturing and Saving the Ladder Monitor View on a CF Card ... 2-14 2.5.1 Details ... 2-14 2.5.2 Setup Procedure ... 2-14

Chapter 3 Ladder Monitor Screen Features

3.1 Main Screen ... 3-2 3.2 File Selection Screen ... 3-6 3.3 Menu Screen ... 3-8

Chapter 4 Restrictions

(9)
(10)

1-1

1 Summary

1.1 Ladder Monitor ...1-2 1.2 System Configuration...1-3 1.3 Installation Procedure ...1-6

(11)

Ladder Monitor

1.1 Ladder Monitor

The ladder monitor is a feature that reads and monitors the external device (OMRON Corporation PLC CS/CJ series) ladder programs on a display screen.

It monitors the ladder programs online without stopping other features.

You can use the ladder monitor feature to do the following:

• Monitor the ladder program of the external device over the internet

Displays the contact, coil and output instruction in bold/color while they are energized Display the I/O comments in the ladder program

• Specify and display the ladder program you wish to check

Display the ladder monitor simultaneously with the alarm display Search for a step number or a device address

• Save the desired ladder program view Capture and save the image on a CF Card Print the desired ladder program view

• The ladder monitor mode calls the device monitor feature.

)

“3.3 Menu Screen” (page 3-8) See: GP-Pro EX Reference Manual

7 1 4 0 8 2 5 . 9 3 6

Production Input Screen

Ladder Monitor

(12)

System Configuration

PLC Ladder Monitor Operation Manual

1-3 1.2 System Configuration

„ Communication Cable Connection

Display device units: Displays the connection status through the external device units.

• The display and external device are connected 1:1 with a connection cable.

• 1-to-n connection (Only with link connection)

• 1-to-n connection (When accessing the link connection by surpassing the network.)

• For details regarding the connection of display devices and external devices, refer to “CS/CJ Series HOST Link Drivers” or “CS/CJ Series Ethernet Drivers” in the “GP-Pro EX Device Connection Manual.”

7 1 4 0 8 2 5 . 9 3 6 Production System Parameter Settings

CLR DEL Cancel

E N T -

Display

CS1 series

Connection cable

Display

External device

External device

External device Up to 16 units

Display

External device

External device

Up to 16 units

(13)

System Configuration

• 1-to-1 connection (Ethernet connection)

• 1-to-n connection (When accessing the Ethernet connection by surpassing the network.)

• 1-to-n connection (Ethernet connection)

Display

HUB

CS1 series

Connection cable

Display

External device

External device

Up to 32 units HUB

Display

External device

Up to 32 units

External Device External

device HUB

HUB

(14)

System Configuration

PLC Ladder Monitor Operation Manual

1-5

• n-to-1 connection (Ethernet connection)

• n-to-m connection (Ethernet connection)

• Through Ladder Monitor functions, the supported Ethernet transfer protocols are TCP/IP and UDP/IP.

Display

HUB

Display Display

External device

Display

External device

External device

Up to 32 units

External device HUB

Display Display

(15)

Installation Procedure

1.3 Installation Procedure

• GP-Pro EX Manual and the Hardware Manual are available for download on Create a project file

Install the startup file onto a CF Card

1

Install the add-on kit

2 )

“2.2.2 Setup Procedure” (page 2-4)

3

See: GP-Pro EX Reference Manual

4

Configure the

device monitor

)

“2.2.2 Setup Procedure” (page 2-4)

5

Transfer the project file with the device monitor settings to the display

See: GP-Pro EX Reference Manual

7

Install the CF Card

8

Connect the display and PLC

See: “CS/CJ Series HOST Link Drivers” or “CS/CJ Series Ether- net Drivers” in “GP-Pro EX Device Connection Manual”

)

“2.2.2 Setup Procedure” (page 2-4)

9

Start up the Ladder

Monitor feature

)

“2.2.2 Setup Procedure” (page 2-4)

6

Convert comment file

See: “Start up procedure from the 2.2.2 Setup Procedure Step 6”

(page 2-8)

See: GP3000 Series Hardware Manual

(16)

2-1

2 Using the Ladder Monitor

2.1 Settings Menu ...2-2 2.2 Monitoring the Ladder Programs of the External Device on a Display...2-3 2.3 Displaying Ladder Programs in Alarm History View... 2-11 2.4 Printing the Ladder Monitor View from a Display ...2-13 2.5 Capturing and Saving the Ladder Monitor View on a CF Card ...2-14

(17)

Settings Menu

2.1 Settings Menu

Monitoring the Ladder Programs of the External Device on a Display

You can display the ladder program of the external device on a display screen.

)

“2.2.1 Details” (page 2-3)

)

“2.2.2 Setup Procedure” (page 2-4)

Displaying the Relevant Ladder Programs Simultaneously from Alarm History

You can display the device for which the alarm is sounding directly from the alarm history screen.

)

“2.3.1 Details” (page 2-11)

)

“2.3.2 Setup Procedure” (page 2-11)

Printing the Ladder Monitor Screen on a Display

You can output the Ladder Monitor screen from a printer connected to the display.

)

“2.4.1 Details” (page 2-13)

)

“2.4.2 Setup Procedure” (page 2-13)

Capturing and Saving the Ladder Monitor Screen on a Display onto a CF Card

)

“2.5.1 Details” (page 2-14)

)

“2.5.2 Setup Procedure” (page CF Card

2003/12/13 2003/12/13 2003/12/13

20:14

20:02 20:08

2003/12/13 2003/12/13 2003/12/1319:30

19:40 20:00 Date Trig Message ACK Recov

Conveyor Stopped Hot Pipe Hot Pipe

Voltage Error Voltage Error Voltage Error

Ladder Monitor

CF Card Snapshot Save

(18)

Monitoring the Ladder Programs of the External Device on a Display

PLC Ladder Monitor Operation Manual

2-3

2.2 Monitoring the Ladder Programs of the External Device on a Display

2.2.1 Details

With the Ladder Monitor you can remotely view, search, and edit the ladder program of the external device as it appears on the HMI.

• See the following pages for the detailed settings.

)

Chapter3 "Ladder Monitor Screen Features" (page 3-1)

• The CF Card must have 256 MB or more of free space.

• See the following pages for the search feature.

)

“3.3 Menu Screen” (page 3-8) CF Card

(19)

Monitoring the Ladder Programs of the External Device on a Display

2.2.2 Setup Procedure

1

Install the Ladder Monitor CD-ROM onto a PC installed with GP-Pro EX. Run Setup.exe on the CD to launch the installer. Follow the installer instructions to install.

2

Install the startup file on a CF Card.

1) Install a CF Card onto the PC.

2) Start the installer by clicking on the Setup.exe file on the ladder monitor CD-ROM.

3) Select the setting language.

4) The OMRON Corporation CS/CJ Series PLC Ladder Monitor Setup Program will launch.

Enter the serial no. and key code. A window appears prompting you to select an install location. Set the CF Card root directory (i.e. the top directory) as the install location.

5) The startup file will be installed.

3

Create a project file.

There are four ways to start the Ladder Monitor. To start the monitor without using the system menu, you must configure the settings for starting the Ladder Monitor in GP-Pro EX in advance.

• System menu

• Switch parts

• LS area

• System variables:

#H_LadderMonitor (no cache)

#H_LadderMonitorCache (with cache)

• Your PC must have GP-Pro EX Ver.2.00 or later installed. For the OS, see the GP-Pro EX Reference Manual.

• To use this feature, the CF Card must have 256 MB or more of free space.

• To start up using the system menu, see the following pages.

)

Setup Procedure 9 “Start up the Ladder Monitor.” (page 2-9)

(20)

Monitoring the Ladder Programs of the External Device on a Display

PLC Ladder Monitor Operation Manual

2-5

„

Start up procedure from switch parts

1) From the [Parts (P)] menu, point to [Switch Lamp (C)] and select [Special Switch (P)] or click . Click and drag to place a switch is placed on the screen.

2) Double-click the switch you placed and in [Special Action] select [Start monitor switch]. In [Action], select [Ladder Monitor] or [Ladder Monitor (Cache)].

• Ladder Monitor

Reads the ladder programs from the external device every time you click the switch.

The ladder program that is being forwarded is displayed on the external device but it may take time to read.

• Ladder Monitor (Cache)

Reads the ladder programs saved on the CF Card when you click the switch, reducing the read time.To update the ladder programs on the CF Card, in [Main Screen] on the display, select [Read].

)

“3.1 Main Screen” (page 3-2)

Production Input Screen

Ladder Monitor 7 1 4 0 8 2 5 . 9 3 6 -

E N T

(21)

Monitoring the Ladder Programs of the External Device on a Display

3) Select [Select Shape], [Color], [Label], and any other features you require and click OK.

• Read the cache from a CF Card

Normally, every time you start the Ladder Monitor, it communicates with the PLC to read the ladder programs and it may take time to display the ladder programs. To improve the display update speed, the Ladder Monitor feature reads the ladder programs of the external device onto the device CF Card (cache) first and then displays them.

If you change the ladder programs on the external device after reading the ladder programs of the external device to the display CF Card, read the ladder programs to the CF Card again. In [Menu Bar] on the display, select [Read].

)

“3.1 Main Screen” (page 3-2)

Reading to the CF Card (cache)

(22)

Monitoring the Ladder Programs of the External Device on a Display

PLC Ladder Monitor Operation Manual

2-7

„ Start up procedure from the LS area

The Ladder Monitor starts up if you turn ON bits in the LS area. Configure the settings for turning ON the following bits using switch parts and D-scripts.

Bit 1 Turn ON to start up the Ladder Monitor.

Bit 3

Turn ON to start the Ladder Monitor and display the ladder programs cached on the CF Card.

• If the programs are not cached in advance, the bit only triggers the same action as Bit 1 turning ON (starts up the Ladder Monitor). To update the ladder programs on the CF Card, in [Main Screen] on the display, select [Read].

)

“3.1 Main Screen” (page 3-2)

• Bits other than Bits 1 and 3 are reserved. Do not use them.

• LS area addresses will be automatically cleared when Ladder Monitor is shutdown.

LS2078

15 1 3 2

Reserved

1: Starting up the Ladder Monitor Reserved

1: Reading the cache data Reserved

(23)

Monitoring the Ladder Programs of the External Device on a Display

4

Register the device monitor feature. In GP-Pro EX, from [System Settings], point to [Display Unit] and select [Extended Settings]. Select the [Device Monitor] checkbox.

5

Save and transfer the project file to the display.

Reference: GP-Pro EX Reference Manual

6

Using the comment file converter tool, the comment file created by CX-Programmer (∗∗∗.cxt) will be converted into a file that is read by the display device (∗∗∗.ocm).

1) Double click ComCvtEX.exe in the CD-ROM of Ladder Monitor to start the comment converter tool.

2) The “GP-Pro EX CS/CJ Series Ladder Monitor Comment File Converter” dialog box will open. Configure the various articles below.

CXT File Name: Using “Browse”, select the CXT file name (∗∗∗.cxt) to be converted.

PC Name: Select the desired output PC name from the CXT file as a comment file.

Output File Name:Input the file name (∗∗∗.ocm) after restoration, or select it by using

• The device monitor screen uses a global display window. While the device monitor is displayed, the screen cannot display other global windows. When you select the [Device Monitor] checkbox, [Global Window] operation is automatically set to [Indirect].

• For manual settings, in the display system menu, point to [Offline], select [Main Unit], and select [Window Settings]. Configure the following settings in [Global Window Operation]:

Global Window Operation: Indirect

Data Type : BIN

(24)

Monitoring the Ladder Programs of the External Device on a Display

PLC Ladder Monitor Operation Manual

2-9 7

Install the CF Card onto the GP.

Reference: For details on installing a CF Card, see “GP3000 Series Hardware Manual”.

8

Connect the display to communicate with the external device.

Reference: For details on the connection, see “GP-Pro EX Device Connection Manual”

9

Start up the Ladder Monitor.

There are four ways to start up the Ladder Monitor.

• System menu

• Switch parts

• LS area

• System variables:

#H_LadderMonitor (no cache)

#H_LadderMonitorCache (with cache) Ladder Monitor

Startup Detail

Start up with the System Menu

On the screen, touch the top left → on the bottom right (or the top right → on the bottom left) in this order within 0.5 Seconds to display the system menu. Touch the [Ladder Monitor] button to display the main screen.

• To start up using switch parts or the LS area, see the following pages.

)

Setup Procedure “„ Start up procedure from switch parts” (page 2-5)

)

Setup Procedure “„ Start up procedure from the LS area” (page 2-7)

Ladder Monitor

or

(25)

Monitoring the Ladder Programs of the External Device on a Display

10

When the ladder monitor starts up, the Device/PLC Selection screen is displayed.

Select the external device for the ladder program you wish to monitor. The screen jumps to the File Selection screen.

• For the File Selection screen, see the following pages.

)

“3.2 File Selection Screen” (page 3-6)

(26)

Displaying Ladder Programs in Alarm History View

PLC Ladder Monitor Operation Manual

2-11

2.3 Displaying Ladder Programs in Alarm History View

2.3.1 Details

Place the Ladder Monitor startup switch on the alarm history screen. This allows you to display the device whose the alarm is sounding directly from the history screen.

2.3.2 Setup Procedure

1

Place the Ladder Monitor startup switch on the alarm history screen.

)

“2.2 Monitoring the Ladder Programs of the External Device on a Display” (page 2-3)

2

On the alarm history screen, touch the alarm you wish to monitor.

Next, touch the Ladder Monitor startup switch.

2003/12/13 2003/12/13 2003/12/13

20:14

20:02 20:08

2003/12/13 2003/12/13 2003/12/1319:30

19:40 20:00 Date Trig Message ACK Recov

Conveyor Stopped Hot Pipe Hot Pipe

Voltage Error Voltage Error Voltage Error

Ladder Monitor

Ladder Monitor

2003/12/13 2003/12/13 2003/12/13

20:14

20:02 20:08

2003/12/13 2003/12/13 2003/12/1319:30

19:40 20:00 Date Trig Message ACK Recov

Conveyor Stopped Hot Pipe Hot Pipe

Voltage Error Voltage Error Voltage Error

Ladder Monitor

2003/12/13 2003/12/13 2003/12/13

20:14

20:02 20:08

2003/12/13 2003/12/13 2003/12/13 19:30

19:40 20:00 Date Trig Message ACK Recov

Conveyor Stopped Hot Pipe Hot Pipe

Voltage Error Voltage Error Voltage Error

(27)

Displaying Ladder Programs in Alarm History View

3

After reading is complete, the device search keypad will be displayed

The device address you selected on the alarm history screen is automatically entered.

Touch [Search]

4

The ladder programs will be displayed starting with the device for which the alarm sounded.

• Select the appropriate external device and read it. After reading is completed the device search keypad is displayed.

• The previously read ladder program is displayed again. Therefore, the ladder program for which the alarm sounded may not be displayed when multiple devices are connected. If this occurs, delete the cache data (LADDER.DAT) from the CF Card and start the ladder monitor from the alarm history. Cache

(28)

Printing the Ladder Monitor View from a Display

PLC Ladder Monitor Operation Manual

2-13

2.4 Printing the Ladder Monitor View from a Display

2.4.1 Details

You can output the Ladder Monitor screen from a printer connected to the display.

This allows you to efficiently save and analyze data.

2.4.2 Setup Procedure

1

Connect the display to the printer.

Reference: GP-Pro EX Reference Manual

2

On the Ladder Monitor main screen, touch [Print].

(29)

Capturing and Saving the Ladder Monitor View on a CF Card

2.5 Capturing and Saving the Ladder Monitor View on a CF Card

2.5.1 Details

You can capture and save the Ladder Monitor screen on a CF Card.

This allows you to efficiently save and analyze data.

2.5.2 Setup Procedure

1

On the Ladder Monitor main screen, touch [Capture].

2

The currently displayed screen is captured. A folder titled "CAPTURE" is automatically created in the CF Card root directory (i.e. the top directory), and the data is automatically saved to this folder. The file name is “CP∗∗∗∗∗_GP.jpg” and ∗∗∗∗∗ is an automatically assigned number from 0 to 65535.

• The time required for screen capture differs depending on the image quality and screen size. The file size for an image quality of 80 is approximately 200k bytes, and the capture (snapshot) takes 5 to 6 seconds. To change the

CF Card

Illuminated in red during capturing

(30)

3-1

3 Ladder Monitor Screen Features

3.1 Main Screen ...3-2 3.2 File Selection Screen ...3-6 3.3 Menu Screen...3-8

(31)

Main Screen

3.1 Main Screen

Names and Features on the Main Screen

Setting/Notated

Items Setting/Notated Contents

Menu

This displays the menu screen.

For details, see the following pages.

)

“3.3 Menu Screen” (page 3-8) Read

This displays the file selection screen where you select the ladder program to read.

For details, see the following pages.

)

“3.2 File Selection Screen” (page 3-6)

Continued

Step number

Power bar

Error display I/O comments

Current Value

Power bar

(32)

Main Screen

PLC Ladder Monitor Operation Manual

3-3

Unsigned decimal/

Signed decimal/

Hexadecimal

This switches between decimal, binary-coded decimal, and hexadecimal current values. The switch display changes between [Decimal] and [Hexadecimal] every time it is touched.

• Ccurrent values are displayed in the following two ways:

Contact/Coil

Displays energized/non-energized state by the thickness of parts lines.

An energized state is displayed in bold lines.

Decimal/Binary-coded decimal/Hexadecimal

Data is displayed in parallel with devices. Current values for bit devices are displayed in bits. Current values for word devices are displayed in words.

[ CMP D100 D200 ]

00256 00256

[ CMP D100 D200 ]

00FF 00FF 0.00

Energized

0.01 Non-energized Contact/Coil

Decimal/

Binary-coded decimal/

Hexadecimal

Current values

Continued Setting/Notated

Items Setting/Notated Contents

(33)

Main Screen

Comment

This selects the display method for I/O comments.

Touch to switch Short Comment Mode --> Compressed Comment Mode - -> No Comment Mode in this order.

• Short comment mode

This displays up to 5 single-byte characters x 3 lines of comments.

• Compressed comment mode

This displays up to 5 single-byte characters x 3 lines of comments.

This displays the characters compressed to 1/2 vertical size.

• No comment mode

This displays no I/O comments.

• To see the full comments when only a portion is displayed, touch the relevant comment. The number of characters displayed in the bottom left of the screen changes depending upon the screen size.

Print This prints the Ladder Monitor screen.

Capture This captures and saves the Ladder Monitor screen to a CF Card.

Exit This closes the Ladder Monitor.

This scrolls the Ladder Monitor screen line by line.

This takes you to the previous/next page.

This shows the block program. When the block program that used the BPRG command appears, CX-Programmer will be displayed at the same time as a mnemonic expression.

Setting/Notated

Items Setting/Notated Contents

I/O comments

(34)

Main Screen

PLC Ladder Monitor Operation Manual

3-5

• The ladder rungs that you can display differ depending on the comment mode.

Type Window Size

No Comments

16 x 16 Comments

16 x 8 Comments

VGA 640 x 480 10 lines 4 lines 6 lines

SVGA 800 x 600 13 lines 5 lines 8 lines

XGA 1024 x 768 17 lines 7 lines 10 lines

(35)

File Selection Screen

3.2 File Selection Screen

Names and Features on the File Selection screen

Setting Description

Ladder Files

type

This displays the ladder type.

CYCLE: Cycle program

INTERRUPT: Interrupt program no. This displays the ladder number.

program

name This displays the program name.

P

This displays the status of the program property, “Task Reading Protection,” and display the presence or absence of reading protection.

* : Protected

Comment Files

file name

This displays the list of comment files on the CF card.

OMR_FINS: Up to 10 single-byte character or 5 double-byte character will be displayed.

OMR_FINE: Up to 36 single-byte character or 18 double-byte character will be displayed.

size This displays the file size up to 8 digits.

date This displays the update date.

time This displays the update time.

Ladder Storage

PC This reads the list of ladder programs from the PLC.

CACHE This reads the list of ladder programs that has been cached on the CF card.

(36)

File Selection Screen

PLC Ladder Monitor Operation Manual

3-7

OK

This reads the ladder programs onto a CF Card.

• The read button triggers saving of only ladder programs and comments to the CF Card. It always reads and displays the latest numeric values from the external device.

If you change the ladder programs or comments on the PLC after reading the data of the external device to the CF card of the display, the Ladder Monitor for the display will not be updated. Read the data again to update the saved data.

Cache the ladder programs on the CF Card to increase the display speed instead of reading data from the external device every time.

• To display the comment line, copy the comment file (***.ocm) into the folder below the CF card.

When using CS/CJ Series HOST Link Driver: PLCLDMON\OMR_FINS When using CS/CJ Series Ethernet Driver: PLCLDMON\OMR_FINE

)

“3.2 File Selection Screen” (page 3-6)

When reading and displaying the comment information from the CF card again, convert the comment file created with the Omron Corporation programming tool, CXProgrammer, with the Digital Comment Editor Tool.

)

“Start up procedure from the 2.2.2 Setup Procedure Step 6” (page 2-8)

For details on comment and ladder files, see below.

)

“3.2 File Selection Screen” (page 3-6)

/Cancel This closes the file selection screen and returns to the previously displayed screen.

Setting Description

Reading to a CF Card

(37)

Menu Screen

3.3 Menu Screen

Setting Description

Step Search

This searches by the step number (number of steps) of the ladder program.

This displays the ladder program with the specified step number (number of steps) at the top of the screen.

Device Search

This searches by the device address.

This displays the ladder program with the specified device address at the top of the screen.

(38)

Menu Screen

PLC Ladder Monitor Operation Manual

3-9

Coil Search

This searches by output instruction.

This displays the ladder program with the specified output instruction at the top of the screen.

Device monitor This displays the device monitor screen.

This closes the menu screen and returns to the previously displayed screen.

• For the device monitor feature, see the following manual.

See: GP-Pro EX Reference Manual

Setting Description

(39)

Menu Screen

(40)

4-1

4 Restrictions

(41)

Ladder Monitor Restrictions

• Depending on the version, your programming tool may not be able to display ladder programs. For the versions supporting programming tools, see the Pro-face support site

“Otasuke Pro!”. For the instructions that you can monitor, see the manual of the external device.

• To use this feature, your CF Card must have 256 MB or more of free space.

• When reading the ladder program, you cannot read only the comment file.

• The maximum amount of lines displayed for one ladder program is 25. The 26th line and after are not displayed. If you specify a device located in the 26th line or after when searching for a device, the start of the circuit where the device is located will be displayed but the specified device itself will not be displayed.

• The power flow is shown by the contact/coil in bold, but the lines connecting contacts to contacts do not change.

• The time taken for a screen capture depends on the image quality and screen size. The file size for a screen quality of 80 will be approximately 200 KB and the capture will take about 5 to 6 seconds.

• If you continuously touch the capture (snapshot) button, the screens may not be captured properly. Allow some time between captures (snapshots).

• Ladder program and comment password settings are not supported. When a [Stop Read/

Write] password is used, reads will cause a communication error.

• Please use CF Cards manufactured by Pro-face (Digital Electronics Corporation). If using another company’s CF Card, damage may occur to the CF Card data.

• Only English and Japanese can be used for the font.

• Even when the ladder program has been task reading protected, if the task reading protection password in PLC has not been set, reading is possible.

• I/O comments cannot be read from the PLC.

• Instance names of function blocks, function block names that are called, and parameter names will not be displayed.

• The content of function blocks will not be displayed.

• Floating decimal points of monitor values cannot be displayed.

• Other program files besides ladder cannot be read or displayed.

(42)

PLC Ladder Monitor Operation Manual

4-3

„ Error Messages

Error Messages Solution

There is no CF-Card in the GP. Please check if the CF Card is inserted properly.

It failed to read a file in the CF- Card.

• Please check if the CF Card is inserted properly.

• When the ladder program is set as CACHE, it is possible that a cache does not exist on the CF Card. In this case, read the ladder program again.

It failed to write a file in the CF- Card.

• Please check if the CF Card is inserted properly.

• Please check if the CF Card has enough space.

• Check that the “PLCLDMON\OMR_FINS” or

“PLCLDMON\OMR_FINE” folders on the CF Card are not set to “ReadOnly”.

It failed to load the Ladder Monitor.

• Please check for damage to the CF Card.

• Please format the CF card to either FAT32 or FAT, and try again.

The Ladder Monitor can’t start because the Runtime version is old.

Use the latest version of GP-Pro EX and download the system to the display.

The Ladder Monitor can’t start because the version is old.

Install the latest version of the ladder monitor onto the CF card.

)

“2.2.2 Setup Procedure” (page 2-4) There are unsupported

instructions.

This message appears when an instruction is used that is not supported by the Ladder Monitor. Please check the version of the programming tool.

The communication error occurred.

Please check if the external device and cables are connected properly. If a password is used in the ladder program file, please remove that password.

There is no enough memory. The comment file size is too large. Please reduce the size of the file.

(43)

參考文獻

相關文件

The difference resulted from the co- existence of two kinds of words in Buddhist scriptures a foreign words in which di- syllabic words are dominant, and most of them are the

了⼀一個方案,用以尋找滿足 Calabi 方程的空 間,這些空間現在通稱為 Calabi-Yau 空間。.

 Promote project learning, mathematical modeling, and problem-based learning to strengthen the ability to integrate and apply knowledge and skills, and make. calculated

Wang, Solving pseudomonotone variational inequalities and pseudocon- vex optimization problems using the projection neural network, IEEE Transactions on Neural Networks 17

volume suppressed mass: (TeV) 2 /M P ∼ 10 −4 eV → mm range can be experimentally tested for any number of extra dimensions - Light U(1) gauge bosons: no derivative couplings. =>

Define instead the imaginary.. potential, magnetic field, lattice…) Dirac-BdG Hamiltonian:. with small, and matrix

• Formation of massive primordial stars as origin of objects in the early universe. • Supernova explosions might be visible to the most

2-1 註冊為會員後您便有了個別的”my iF”帳戶。完成註冊後請點選左方 Register entry (直接登入 my iF 則直接進入下方畫面),即可選擇目前開放可供參賽的獎項,找到iF STUDENT