• 沒有找到結果。

[PDF] Top 20 An improved method for measuring refractive-index of a medium

Has 10000 "An improved method for measuring refractive-index of a medium" found on our website. Below are the top 20 most common "An improved method for measuring refractive-index of a medium".

An improved method for measuring refractive-index of a medium

An improved method for measuring refractive-index of a medium

... Finally, substituting this phase variation into the equations derived from Fresnel's equations and Jones calculus, we can obtain the refractive index ofthe test medium.. Keywords: index [r] ... See full document

8

Improved method for measuring small optical rotation angle of chiral medium

Improved method for measuring small optical rotation angle of chiral medium

... principle of Feng et al., an improved optical method for measuring small rotational angle in chiral medium is ...When a quarter-wave plate and two analyzers with ... See full document

6

A method for measuring the complex refractive index of a turbid medium

A method for measuring the complex refractive index of a turbid medium

... complex refractive index, turbid medium. 1. INTRODUCTION A turbid medium is an important biochemical ...complex refractive index is not only related with ... See full document

8

Improved technique for measuring refractive index and thickness of a transparent plate

Improved technique for measuring refractive index and thickness of a transparent plate

... Keywords: Refractive index; Thickness; Phase measurement; Heterodyne interferometry ...Introduction A transparent plate such as glass plate is often used in optics and semiconductor ...Its ... See full document

6

Method for measuring the refractive index distribution of a GRIN lens with heterodyne interferometry

Method for measuring the refractive index distribution of a GRIN lens with heterodyne interferometry

... interferometry, an alternative method for measuring the refractive index distribution of a GRIN lens is ...presented. A light coming from the heterodyne ... See full document

9

An alternative method for measuring the index profile of a gradient-index lens

An alternative method for measuring the index profile of a gradient-index lens

... feasibility of this method, a GRIN lens (AC Photonics, ...with a diameter of 1.8mm was tested. An He-Ne laser with a wavelength of ...used. A CMOS camera ... See full document

7

Alternative method for measuring the full-field refractive index of a gradient-index lens with normal incidence heterodyne interferometry

Alternative method for measuring the full-field refractive index of a gradient-index lens with normal incidence heterodyne interferometry

... 2010 A linearly/circularly polarized heterodyne light beam coming from a heterodyne light source with an electro-optic modulator in turn enters a modified Twyman –Green interferometer to ... See full document

5

A method for measuring two-dimensional refractive index distribution by using Fresnel equations and phase-shifting interferometry

A method for measuring two-dimensional refractive index distribution by using Fresnel equations and phase-shifting interferometry

... Introduction Refractive index is an important char- acteristic constant of optical ...proposed for measur- ing refractive index, almost all of them are used to ... See full document

4

A Spatial Beam Splitter Consisting of a Near-Zero Refractive Index Medium

A Spatial Beam Splitter Consisting of a Near-Zero Refractive Index Medium

... composed of metallic mesh wires, which has very small electrical length in the period and wire thickness, can be treated as a homogeneous medium with a low plasma frequency ...domain, a ... See full document

4

A method for measuring two-dimensional refractive index distribution with the total internal reflection of p-polarized light and the phase-shifting interferometry

A method for measuring two-dimensional refractive index distribution with the total internal reflection of p-polarized light and the phase-shifting interferometry

... tion of the p-polarized light at the boundary between a right-angle prism and a tested material under the total internal ...two-dimensional refractive index distribution of ... See full document

4

An Efficient Method for Computing Optical Waveguides With Discontinuous Refractive Index Profiles Using Spectral Collocation Method With Domain Decomposition

An Efficient Method for Computing Optical Waveguides With Discontinuous Refractive Index Profiles Using Spectral Collocation Method With Domain Decomposition

... proposed an efficient solution method that com- bines spectral collocation method and domain decomposition for computing optical waveguides with discontinuous refrac- tive index ... See full document

13

Improved common-path optical heterodyne interferometer for measuring small optical rotation angle of chiral medium

Improved common-path optical heterodyne interferometer for measuring small optical rotation angle of chiral medium

... resolution of the opti- cal rotation angle. The optical configuration of HAUP is the conventional polarimetry setup, and its method is based on a least-squares refine- ment of the ... See full document

5

Alternative method for measuring both the refractive indices and the thickness of silver-halide holographic plates

Alternative method for measuring both the refractive indices and the thickness of silver-halide holographic plates

... because of their high sensitivity and commercial ...and refractive indices strongly influence the characteristics of ...quality of a hologram, it is very important to measure accurately ... See full document

6

Improved technique for measuring small angles

Improved technique for measuring small angles

... that of Huang’s system. The light beam coming from a heterodyne optical source 10 with the frequency difference f be- tween s- ~y-axis! and p-~x-axis! polarizations is in- cident on the beam splitter, BS, ... See full document

3

Measurements of material refractive index with a circular heterodyne interferometer

Measurements of material refractive index with a circular heterodyne interferometer

... Keyword: refractive index, circular heterodyne interferometer, isotropic material, birefringent crystal, Fresnel ...devices, for example, birefringent laser cavity filters 1 , poled-polymer ... See full document

11

Two-dimensional refractive index distribution measurement of a GRIN lens

Two-dimensional refractive index distribution measurement of a GRIN lens

... light, refractive index, GRIN lens, phase-shifting interferometry, electro-optic modulator ...symmetry of the refractive-index distribution directly influence its product ...full-field ... See full document

8

Full-field refractive index distribution measurement of a gradient-index lens with heterodyne interferometry

Full-field refractive index distribution measurement of a gradient-index lens with heterodyne interferometry

... interferemetry, an alternative method for measuring the full- field refractive index distribution of a GRIN lens has been ...the AN and the IL, and is ... See full document

6

Precise measurement of group refractive indices and temperature dependence of refractive index for Nd-doped yttrium orthovanadate by intracavity spontaneous mode locking

Precise measurement of group refractive indices and temperature dependence of refractive index for Nd-doped yttrium orthovanadate by intracavity spontaneous mode locking

... setup for measuring the group refractive indices and the temperature depen- dence of refractive ...used a simple concave- plano configuration to construct the laser cavity and ... See full document

3

A method for measuring the rotatory power of a chiral medium

A method for measuring the rotatory power of a chiral medium

... A light beam coming from a circularly polarized heterodyne light source passes through a chiral medium, its rotation angle is just half of the phase difference between p- and s- polariza[r] ... See full document

8

A method for measuring the concentration of a solution

A method for measuring the concentration of a solution

... When a linearly polarized light beam enters a surface-plasmon-resonanse (SPR) apparatus and is incident on the boundary surface with tested solution at the resonant angle, the phase diff[r] ... See full document

2

Show all 10000 documents...