• 沒有找到結果。

以毛細管電泳之雷射誘發螢光分析唾液中分析型免疫球蛋白

N/A
N/A
Protected

Academic year: 2021

Share "以毛細管電泳之雷射誘發螢光分析唾液中分析型免疫球蛋白"

Copied!
2
0
0

加載中.... (立即查看全文)

全文

(1)

以毛細管電泳之雷射誘發螢光分析唾液中分析型免疫球蛋白 A 之含

Analysis of secretory IgA in human saliva by laser induced fluorescence capillary electrophoresis

中文摘要

許多疾病引起的變化可從唾液中偵測出來,唾液的檢驗日益受到重視,因為檢體來 源取得方便且為非侵入性,用其來發展相關的疾病檢驗或當作生理健康指標有其 特殊意義。人體唾液中之分泌型免疫球蛋白 A,secretary IgA (sIgA),為身體抵抗外 來物侵襲的第一道防線,病毒或細菌的感染會造成唾液中的(sIgA)增加,而壓力累 積或免疫衰竭時 sIgA 則減少,唾液中 sIgA 多寡,可反應出個人免疫力之強弱,也可 視為一種健康指標。毛細管電泳是一種具有潛力的分析工具,它具備快速、簡單、

解析度高並能自動化的優點。本文研究的目的是利用毛細管電泳儀對唾液中之 sIgA 含量, 尋找出最佳化的分析條件, 及建立定量分析的方法。由於唾液中之 sIgA 含量較血清為低, 以 UV/vis 作偵測其靈敏度不夠, 所以本實驗採用雷射激 發螢光法(Laser induced fluorescence ,LIF)來提高偵測靈敏度,以 Cy5 為螢光劑,其 最大激發波長在 649nm, 散射光波長在 670nm。毛細管電泳法採 (Capillary zone electro- phoresis,CZE)並以競爭性毛細管免疫測定法 (competitive capillary

immunoassay) 和非競爭性免疫測定法(direct immunoassay)分析受試者於考試前 後唾液中的 sIgA 含量之變化。其結果顯示前者穩定不如後者,以抗原抗體反應形 成複合體之量與抗原之量成正比,以純化之 sIgA 建立標準曲線,由此一曲線從被 測者之複合體在電泳圖中形成之波峰及內在標準(internal standard)之波峰可以計 算出 sIgA 之含量。

英文摘要

Saliva is extremely sensitive to changes in oral and systemic diseases. As a new role for clinical tool, saliva offers many advantages over serum, saliva is easy to collect, painless and non invasive. It can be used as an indicator on the status of individual immunity. Secretory immunoglobulin A (sIgA) is the most abundant immunoglobulin in saliva and plays an important role in mucosal immunity. sIgA measurement in saliva as an index of mucosal immunity, has repeatedly been shown sensitive to physiological variables. For instance increase level comes after bacterial or viral infections, contrary reduction level can be observed while under stressful

circumstances.

Capillary electrophoresis (CE) is a new analytical technique for assessment of different variety of body fluids, as it requ.ires only a small volume and provides a

(2)

rapid analysis with high efficient separation. In addition the instrument is easy to be automated. This study aims to establish an optimal condition for CE analyzed trace amount of sIgA in saliva. Laser induced fluorescence (LIF) conducted in capillary electrophoresis improvement of its sensitivity, both of the competitive (CI-CE) and the non competitive (direct) immunoassays (NCI-CE). The fluorescence Cy5 on the maximum absorption at 649 nm and the maximum emission efficiency at 670 nm was used for either sIgA or anti-sIgA labeling. The electrophoresis was conducted under 15kV in borate buffer 150 mM with CHAPS, pH8.5. The method is based on the different mobility of the free and bound tracer (fluorescently labeled compound). The amounts of sIgA in graduate student''s saliva were assessed during the period under stress or stress free. The results indicate that the NCI-CE is more stable and reproducible than the CI-CE for sIgA quantitative analysis.etes.

參考文獻

相關文件

本研究將針對 TFT-LCD 產業研發單位主管與研發人員進行 探討,並就主管於研發人員對職能重視程度作差異性分析。因此

接下來的 FDTD 疊代運算將是整個計算的核心,也是運算量最大 的部分,在這中間,如何利用光波導的性質以及傳播常數等特徵參量

在軟體的使用方面,使用 Simulink 來進行。Simulink 是一種分析與模擬動態

電腦視覺的影像處理與分析在軟體部分,本研究分別使用美國微 軟公司所開發的 Visual C++ 6.0 以及美國 Matrox Imaging 公司所發展 出來的 Matrox Imaging Library 7.0。其中

我們用一因子變異數分析的 F 檢定及 Welch、Brown-Forsythe 的 檢定,從原本的 14 個變數中找出具有區別能力的 10 個變數來做區別 分析。由卡方圖知道四種土壤的 10

本研究於 2017 年 4 月以市面上瓶裝水的品牌隨機抽取國內外各五種品 牌作為研究對象,並利用環檢所公告之採樣方法檢測,收集的樣本以兩種

在集群分析方法中,Stuart Lloyd 於 1957 年提出了 K-Means 分析法。它是利用劃分方 式的ㄧ種聚類算法。此種方式以隨機選取

調整動力分析 動力分析 動力分析之反應譜 動力分析 之反應譜 之反應譜 之反應譜:依據規範規定之設計地震力,. 調整 Scale