• 沒有找到結果。

[PDF] Top 20 METHOD FOR MEASURING THE RETARDATION OF A WAVE PLATE

Has 10000 "METHOD FOR MEASURING THE RETARDATION OF A WAVE PLATE" found on our website. Below are the top 20 most common "METHOD FOR MEASURING THE RETARDATION OF A WAVE PLATE".

METHOD FOR MEASURING THE RETARDATION OF A WAVE PLATE

METHOD FOR MEASURING THE RETARDATION OF A WAVE PLATE

... Recorded signals with the tested quarter-wave plate: upper trace, external modulated signal; middle trace, reference signal; lower trace, test signal.. Results of 10 points across the [r] ... See full document

3

Method for determining the fast axis and phase retardation of a wave plate

Method for determining the fast axis and phase retardation of a wave plate

... paper a novel method is presented that can identify the fast axis of a wave plate and at the same time evaluate its phase ...retardation. The ... See full document

6

Method for measuring the refractive index distribution of a GRIN lens with heterodyne interferometry

Method for measuring the refractive index distribution of a GRIN lens with heterodyne interferometry

... on the Fresnel’s equations and the heterodyne interferometry, an alternative method for measuring the refractive index distribution of a GRIN lens is ...presented. ... See full document

9

Improved method for measuring small optical rotation angle of chiral medium

Improved method for measuring small optical rotation angle of chiral medium

... on the principle of Feng et al., an improved optical method for measuring small rotational angle in chiral medium is ...When a quarter-wave plate and two analyzers ... See full document

6

A method for measuring Brewster's angle by circularly polarized heterodyne interferometry

A method for measuring Brewster's angle by circularly polarized heterodyne interferometry

... new method for determining Brewster’s angle is proposed. First, a linearly polarized laser, an electro- optic modulator and a quarter-wave plate are used to obtain a ... See full document

6

Improved technique for measuring refractive index and thickness of a transparent plate

Improved technique for measuring refractive index and thickness of a transparent plate

... show the feasibility of this method, we measured the thickness and the refractive in- dices of one BK7 plate, one fused silica plate, and one BASF2 plate at ... See full document

6

Fluid dielectric loading on leaky Lamb wave of a piezoelectric plate

Fluid dielectric loading on leaky Lamb wave of a piezoelectric plate

... repeatability of the proposed differential type wave measurement ...developed a leaky Lamb wave measurement system based on the idea of differential mea- ...surement. ... See full document

3

Alternative method for measuring both the refractive indices and the thickness of silver-halide holographic plates

Alternative method for measuring both the refractive indices and the thickness of silver-halide holographic plates

... because of their high sensitivity and commercial availability. Ac- cording to the coupled wave theory, 3 their thickness and refractive indices strongly influence the characteristics of ... See full document

6

Scattering of water wave by a submerged horizontal plate and a submerged permeable breakwater

Scattering of water wave by a submerged horizontal plate and a submerged permeable breakwater

... solved the problem of wave scattering by a submerged, horizontal plate, using a hypersingular integral equation for the discontinuity in the potential across ... See full document

17

A two-point method for estimating wave reflection over a sloping beach

A two-point method for estimating wave reflection over a sloping beach

... Conclusion A frequency-domain method for separating incident and reflected waves is pro- posed in this paper to account for normal incident waves propagating over a sloping ...beach. ... See full document

15

On the measurement of anisotropic elastic constants of fiber-reinforced composite plate using ultrasonic bulk wave and laser generated Lamb wave

On the measurement of anisotropic elastic constants of fiber-reinforced composite plate using ultrasonic bulk wave and laser generated Lamb wave

... Lamb wave; Laser ultrasonics; Non-destructive evaluation ...in the field of non-destructive evaluation of ...nature, the conventional ultrasonic technique lized extensively in ... See full document

8

A New Microsphere-Based Immunoassay for Measuring the Activity of Transcription Factors

A New Microsphere-Based Immunoassay for Measuring the Activity of Transcription Factors

... MIA-TF method has several advantageous charac- teristics, including fast detection, high sensitivity, specific detection, and flexible as well as wide ...circumvent the false positive signals resulting from ... See full document

9

A surface acoustic wave sensor modified from a wireless transmitter for the monitoring of the growth of bacteria

A surface acoustic wave sensor modified from a wireless transmitter for the monitoring of the growth of bacteria

... stated, the measurements were taken half an hour after each inoculation of the cell ...cultures. The frequency was displayed and recorded by the computer until the incubation was ... See full document

7

A method for measuring the concentration of a solution

A method for measuring the concentration of a solution

... When a linearly polarized light beam enters a surface-plasmon-resonanse (SPR) apparatus and is incident on the boundary surface with tested solution at the resonant angle, the phase diff[r] ... See full document

2

A method for measuring the rotatory power of a chiral medium

A method for measuring the rotatory power of a chiral medium

... A light beam coming from a circularly polarized heterodyne light source passes through a chiral medium, its rotation angle is just half of the phase difference between p- and s- polariza[r] ... See full document

8

A method for measuring the complex refractive index of a turbid medium

A method for measuring the complex refractive index of a turbid medium

... INTRODUCTION A turbid medium is an important biochemical ...quality. For example, there is an obvious complex refractive index difference between normal and abnormal tissues, which might be caused by ... See full document

8

A method for measuring the geometrical topography of a Rockwell diamond indenter

A method for measuring the geometrical topography of a Rockwell diamond indenter

... Because of the microscopic configuration of the two- dimensional white light interferometer, the measurable region is restricted and the overall topography cannot be obtained in ... See full document

8

An alternative method for measuring the index profile of a gradient-index lens

An alternative method for measuring the index profile of a gradient-index lens

... alternative method for measuring the index profile of the GRIN lens is proposed based on Fresnel’s equations and the common-path phase-shifting ...interfermetry. A ... See full document

7

An improved method for measuring refractive-index of a medium

An improved method for measuring refractive-index of a medium

... Finally, substituting this phase variation into the equations derived from Fresnel's equations and Jones calculus, we can obtain the refractive index ofthe test medium.. Keywords: index [r] ... See full document

8

A novel method for short leaky-wave antennas to suppress the reflected wave

A novel method for short leaky-wave antennas to suppress the reflected wave

... shows the proposed circuit configuration of the X-band leaky-wave ...antenna. The configuration consists of three parts: a leaky-wave antenna, an aperture, and ... See full document

3

Show all 10000 documents...